PZC Packet 100411Staff Report To Planning and Zoning Commission AVON Thru Sally Vecchio, Com Dev Director c oL o R A o 0 Fr Matt Pielsticker, Planner II Date October 4, 2011 PZC Meeting RE Planned Unit Development (PUD) Amendment Buck Creek PUD Summary On behalf of the property owner, Eagle River Fire Protection District, Pedro Campos ("the Applicant") of Zehren and Associates, is proposing an amendment to the Buck Creek PUD to allow the roof overhangs of two buildings to encroach into the front and side setbacks of Lot 1A, Buck Creek Subdivision. The amendment also requests approval to construct a foot path within portions of a platted 30' Riparian Buffer Zone. Attached to this report is sheets 1 and 2 (Exhibit A) of the Buck Creek PUD Development Plan with highlighted changes. A Resolution (Exhibit B) approving the amendment is also attached. Background The Buck Creek PUD was approved by the Council in 2009. Zoning for the property was established when Council approval of Ordinance 09-08 on August 11, 2009. The PUD Development Plan establishes the development standards for the property including but not limited to allowed uses, parking standards, setbacks, and density. Lot 1A is intended for a fire station, fire district facilities, administrative functions, offices, and employee housing units. In terms of setbacks, the property includes: twenty-five (25') foot front, seven and one-half (75) foot side setbacks, and ten (10') foot rear yard setbacks. The PUD Development Plan includes the following note with respect to Lot 1A setbacks: "The building setbacks depicted on the PUD Development Plan Map for Lot 1A shall constitute a building envelope that shall remain in place and independent of any future changes to the Nottingham Road, Swift Gulch Road or Buck Creek Road Rights of Way." This phrase was added to the Development Plan to ensure that development on Lot 1A could not hinder the construction of a round -a -bout near the intersection of Nottingham Road and Swift Gulch Roads. Property Description Lot 1A is the southernmost lot of the sides by Town right-of-way and future 2.17 acres, and slopes Buck Creek PUD. It is surrounded on the West, South, and East residential development to the north (Lot 113). The lot measures the lot is bisected by Buck Creek. October 4, 2011 Planning and Zoning Commission Meeting Page 1 of 3 Proposed Amendment The applicant is proposing to add the following general notes: General Note 9. "The roof overhang of the Administration Building on Lot 1A shall be allowed to encroach into the 25' front setback and the roof overhangs of the Fire Station Building on Lot 1A shall be allowed to encroach into the 25' front setback and 7.5'side setbacks." General Note 10. "The path on the west side of the administration building on Lot 1A will be allowed to encroach into the 30' Riparian Buffer Zone as represented on Sheet 2." Sheet 2 of the PUD Development Plan shows the proposed building footprints and walkway alignments. A more detailed study of the existing PUD Development Plan compared with this application is included in the plan set and labeled "Sheet 1-1.0". Process Amendments to a Final PUD Plan are administered pursuant to §7.16.020(g), Minor Amendment, ADC The PZC will review this application and shall provide a recommendation to Town Council after conducting a public hearing. The Town Council shall review and render a final decision on a PUD application after holding a public hearing. PUD Review Criteria When reviewing this amendment request, the PZC shall use the following review criteria as set forth in §7.16.060(e)(4), Review Criteria, ADC, as the basis for a recommendation to Council: (i) The PUD addresses a unique situation, confers a substantial benefit to the Town, and/or incorporates creative site design such that it achieves the purposes of this Development Code and represents an improvement in quality over what could have been accomplished through strict application of the otherwise applicable district or development standards. Such improvements in quality may include, but are not limited to: improvements in open space provision and access, environmental protection; tree/vegetation preservation; efficient provision of streets, roads, and other utilities and services; or increased choice of living and housing environments. (fi) The PUD rezoning will promote the public health, safety, and general welfare; (iii) The PUD rezoning is consistent with the Avon Comprehensive Plan, the purposes of this Development Code, and the eligibility criteria outlined in §7.16.060(b); (iv) Facilities and services (including roads and transportation, water, gas, electric, police and fire protection, and sewage and waste disposal, as applicable) will be available to serve the subject property while maintaining adequate levels of service to existing development; (v) Compared to the underlying zoning, the PUD rezoning is not likely to result in significant adverse impacts upon the natural environment, including air, water, noise, storm water management, wildlife, and vegetation, or such impacts will be substantially mitigated; (vi) Compared to the underlying zoning, the PUD rezoning is not likely to result in significant adverse impacts upon other property in the vicinity of the subject tract; and (vii) Future uses on the subject tract will be compatible in scale with uses or potential future uses on other properties in the vicinity of the subject tract. Discussion The proposed amendment is not likely to result in significant adverse impacts to the natural environment or other properties in the vicinity of the property. In fact, the proposed building footprints are largely consistent with the currently approved PUD Development Plan; which implied that building edges on Lot 1A may approach and in some cases border the front setbacks. The path encroachment into the 30' riparian setback is also consistent with the currently approved PUD Development Plan. October 4, 2011 Planning and Zoning Commission Meeting Page 2 of 3 Recommendation Staff recommends approval of Resolution 11-10, thereby recommending that the Avon Town Council approve the PUD Amendment request for Lot 1A, Buck Creek PUD. Exhibits A — Resolution 11-10 B - Applicant Correspondence C — Buck Creek PUD Development Plan (as amended) October 4, 2011 Planning and Zoning Commission Meeting Page 3 of 3 Exhibit A TOWN OF AVON PLANNING & ZONING COMMISSION RESOLUTION NO. 11-10 A RESOLUTION APPROVAL OF A PLANNED UNIT DEVELOPMENT (FUD) AMDENDMENT APPLICATION FOR LOT 1A, BUCK CREEK PUD, BUCK CREEK SUBDIVISION, TOWN OF AVON, EAGLE COUNTY, COLORADO WHEREAS, Zehren and Associates, Inc. ("the Applicant"), representing the owner of the property, Eagle River Fire Protection District, submitted an application to amend the Buck Creek PUD to permit roof overhangs within setbacks and a paved path within a 30' Riparian Buffer Zone; and WHEREAS, at their regularly scheduled meeting held on October 4, 2011 the Planning & Zoning Commission held a public hearing to consider approving the PUD amendment application for portions of the Buck Creek PUD; and WHEREAS, the Planning & Zoning Commission of the Town of Avon considered the following review considerations, as required by the 7.16.060(e)(4), Review Criteria, ADC, as the basis for a recommendation to Council: (i) The PUD addresses a unique situation, confers a substantial benefit to the Town, and/or incorporates creative site design such that it achieves the purposes of this Development Code and represents an improvement in quality over what could have been accomplished through strict application of the otherwise applicable district or development standards. Such improvements in quality may include, but are not limited to: improvements in open space provision and access; environmental protection; tree/vegetation preservation; efficient provision of streets, roads, and other utilities and services; or increased choice of living and housing environments. (ii) The PUD rezoning will promote the public health, safety, and general welfare; (iii) The PUD rezoning is consistent with the Avon Comprehensive Plan, the purposes of this Development Code, and the eligibility criteria outlined an §7.16.060(b); (iv) Facilities and services (including roads and transportation, water, gas, electric, police and fire protection, and sewage and waste disposal, as applicable) will be available to serve the subject property while maintaining adequate levels of service to existing development; Exhibit A (v) Compared to the underlying zoning, the PUD rezoning is not likely to result in significant adverse impacts upon the natural environment, including air, water, noise, storm water management, wildlife, and vegetation, or such impacts will be substantially mitigated; (vi) Compared to the underlying zoning, the PUD rezoning is not likely to result in significant adverse impacts upon other property in the vicinity of the subject tract; and (vii) Future uses on the subject tract will be compatible in scale with uses or potential future uses on other properties in the vicinity of the subject tract. NOW, 'THEREFORE, BE IT RESOLVED, that the Planning & Zoning Commission of the Town of Avon, Colorado, hereby recommends approval of a PUD Amendment for Lot 1A, Buck Creek PUD, Buck Creek Subdivision based on conformance with the cited review criteria. ADOPTED THIS 4t1' DAY OF OCTOBER, 2011 Signed.• Date: Chair: Chris Green Attest: Date: Secretary: Scott Prince aExhibit B Z E H R E N AND ASSOCIATES August 3, 2011 Sally Vecchio Assistant Town Manager / Community Development Director Town of Avon P.O. Box 975 Avon, CO 81620 Email: sveechio(o-)avon.or /Phone: 970-748-4009 RE: Eagle River Fire Protection District Avon. Fire Station & Headquarters Application for Minor PUD Amendment - Buck Creek PUD Lot 1 A Dear Sally: Thank you for considering a minor FUD amendment application for Lot 1A of the Buck Creek PUD in Avon, Colorado. This letter is to summarize the items covered in the application and serves as the narrative to supplement the forms and required documents being submitted concurrently by Zehren and Associates, Inc, as the applicant on behalf of the Eagle River Fire Protection District (ERFPD). The Buck Creek PUD for Lot1A was approved in a manner that `locked in' certain areas for building placement, vehicular and pedestrian access and circulation, parking, and landscaping. Zehren and Associates has completed the Schematic Design of the project and resolved the architectural design and site planning per the PUD requirements. The current plans are consistent with the majority of the intent and requirements of the Buck Creek PUD for Lot IA. Asa result of more detailed study there are some minor items that differ slightly from the approved PUD requirements and standards for Lot IA. In most cases these items address a greater functionality of the site for the intended use as a fire station as well as an enhanced relationship of the project to the surrounding fabric of the town and adjacent uses. As we have discussed, a minor PUD amendment application is required to modify the PUD to be consistent with the current schematic design. We appreciate your consideration of items that deviate from the PUD at this time so the District can proceed with assurance the current direction meets the Town's satisfaction and can continue the detailed design process in the future. None of the current items address design character and style. It is understood as part of the approval process a formal design review by the Town's Planning and Zoning Commission and Town Council will be necessary at a later date, and as part of the required process to apply for and secure a building permit. As may be required by the Minor PUD amendment process the ERFPD will conduct work sessions with the Planning and Zoning Conunission and or Town Council to help in the review of the current plans. This would also serve as forum for ERFPD to share the progress of the project as a `good neighbor' and discuss its importance as a new civic node and entrance element for the Town of Avon in proximity of the Town's main entrance off of Interstate 70. Z E H R E NANO ASSOCIATES, INC, ARCHITECTURE • PLANNING • INTERIORS - LANDSCAPE ARCHITECTURE P.O. BOX 1976 Avon, Colorado 81620 (970) 949-0257 FAX (970)949.1080 aExhibit B Z E H R E N AND ASSOCIATES The items the ERFPD proposes to be reviewed by the Community Development Department via the minor PUD amendment application are as follows: 1) The Buck Creek PUD for Lot IA. requires a range of parking from 46 to 48 total parking spaces. The District is applying the low range of parking required by the PUD for employees associated with the Administration Building and provide a total parking supply of 46 spaces. The District believes 12 total spaces (vs. 14) associated with the Administration Building will meet long term employee parking demand and since the total building area and program has been reduced. The application of the lower range will allow for a more functional parking configuration with no major conflicts between parking stalls, utilities and pedestrian circulation. 2) The District is requesting allowance for roof overhangs to encroach upon front and side setbacks. This condition exists per the approved PUD in the case of the Administration building which is sited on the front set back, necessitating encroachment of roof overhangs. The roof overhangs will not in any circumstance interfere with pedestrian or vehicular circulation routes, nor impact adjacent properties and road right of ways. 3) The District is requesting approval to changes to building footprints, and where there is a shift greater than 10' horizontally but no increase in density or change in building use. Please refer to the notes on the Buck Creek PUD that indicate such shifts in excess of 10' were anticipated and suggest a minor PUD amendment process for such instances. There are a few instances where the current buildings have shifted by more than 10' in order to accommodate internal program space requirements and relationships, without violating setbacks, including the `new' 30' stream setback, or PUD development standards. However, despite shifts, the footprint areas of both building are very close to the PUD footprint areas, and in case of the Administration building the footprint is considerably smaller. Please refer to item #6 below and the proposed development plan for a comparison of the original and proposed footprint areas. 4) The District is requesting the ability to shift the sidewalk along the southern edge of the property line and Nottingham Road, in front of the fire station apparatus bay apron in order to create more useable space in front of the apparatus bay without conflicting with pedestrian circulation. There will be instances where fire protection vehicles will be parked in front of bays and due to their length would interfere with the pedestrian route. By shifting the sidewalk by approximately 4' to the south along the property line this conflict would be resolved. The remainder of the sidewalk along Nottingham Road would remain in the same alignment as is shown in the Buck Creek PUD. S) The District is requesting relief from the on-site snow storage requirement if it cannot be met on-site, and there is an acceptable agreement for off-site snow removal. It is unknown at this time if the full snow storage requirement can be met on-site due the extent of snow melt areas and configuration of landscape and snow storage areas. These will be determined with greater certainty in next steps as the schematic design of the project Z E H R E NAND ASSOCIATES, INC. ARCHITECTURE • PLANNING • INTPRIORS - LANDSCAPE ARCHITECTURE P.O. BOX 1976 Avon, Colorado 81620 (970) 949-0757 FAX (970)949.1080 a Exhibit B L Z E H R E N AND ASSOCIATES evolves. As discussed as part of the FUD hearings, if the snow storage cannot be met onsite a snow management plan will need to be approved to the Town's satisfaction. 6) The District is requesting approval for a reduction in the footprint area for the Administration Building, and an increase in footprint area for the Fire Station Building from what is currently shown in the Buck Creek PUD. The footprint of the Fire Station was 10,925 SF in the PUD, and is 11,294 SF as currently proposed, an increase of footprint of approximately 3%. The footprint of the Administration Building was 6,489 SF in the FUD, and is 5,696 SF as currently proposed, a reduction of approximately 12%. These changes are a result of the evolution of the design process, including interior programming with ERFPD staff and also to maximize the opportunities of the site and PUD layout and functionality of the intended uses. 7) The District is requesting the portion of Lot I that is located to the north and across the new `Walking Mountains Lane' be excluded from the site area applied to the landscape requirements and calculations per the Avon Development Code. This area is 13,021 square feet and represents approximately 13% of the total site area. A majority of the area is within the Buck Creek `bulked floodplain' and / or covered by the driveway heading north to the other lots within the PUD. Furthermore, the area has signage for the Walking Mountains School and will likely also be used by Lot 2 when it is developed. Inclusion of the area, results in a total site landscape area of 44% for LotlA, requiring 837 landscape units per the I unit per 50 square feet calculation required by the Avon Development Code. If the area is excluded, the total site landscape area is reduced to 36%, requiring instead 578 landscape units, applying the same calculation. In preliminary landscape studies, Zehren and Associates have determined that it would be difficult to achieve 837 landscape units per the landscape unit schedule in the Avon Development Code. Given the Lot IA site is predominantly covered by buildings or parking and the nature of proposed uses for emergency and fire response there is insufficient area to accept the volume of plants and landscape features to achieve the 837 units. It would require excessive planting of trees, shrubs, and ground covers along with over -crowding of site elements and furnishings at detriment to pedestrian and automobile circulation and on-site snow storage areas. Therefore, Zehren and Associates recommends the landscape requirements be reduced to include all of the area south of Walking Mountains Lane, constituting the entire area of Lot IA that is otherwise being developed in association with the project. This will result in 36% of total site landscape area, which would still meet and exceed the minimum requirement of 25% landscape area per the approved Buck Creek PUD for all Lots. Sally, thank you again for the opportunity to make this application and the discussions that have taken place leading up to it. We appreciate your time and willingness to review the proposed minor amendment in context with the Buck Creek FUD and the needs of both the District and the Town. If as part of your review you feel it would be beneficial to conduct a meeting and presentation with the Planning and Zoning Commission and or Town Council, please let us know, Z E H R E N AND ASSOCIATES, INC. ARCHITECTURE • PLANNING - INTERIORS � LANDSCAPE ARCHITECTURE f? P.O. BOR 1976 Avon, Colorado 81620 (970) 949.0247 FAX (970)949-1080 aExhibit B Z E H R E N AND ASSOCIATES along with the timing of when such meeting would be appropriate. We will factor it into our work process and your department. Please don't hesitate to call myself or Dave Kaselak should you have any questions regarding the items above or any other project details that may be of relevance. We are excited and much honored to be working on this project for the District and the Town of Avon. As local professionals and residents we are committed to delivering the highest level of quality possible for what is sure to become an important community landmark and civic anchor for the Town of Avon. Sincerely, Pedro Campos, RLA / ASLA Landscape Architect & Land Planner Zehren and Associates, Inc. Cc: Charlie Moore, Eagle River Fire Protection District David Kaselak, Zehren and Associates L Z E H R E N AND ASSOCIATES, INC, ARCHITECTURE � PLANNING • INTERIORS • LANDSCAPE ARCHITECTURE P.O. BOX 1976 Avon, Colorado 81620 (970) 949-0257 FAX (970)949-1080 :0111919 Aatt Pielsticker From: Pedro Campos <pedroc@zehren.com> Sent: Wednesday, August 24, 2011 11:16 AM To: Charlie Moore; karl bauer Cc: Dave Kaselak; Matt Pielsticker; Sally Vecchio; Glenn Palmer; Gary Almgren Subject: Update - ERFPD Lot1A Buck Creek PUD amendment application Chief Moore (Charlie) and Chief Bauer (Karl) This email is an update on the status of the application to the Town of Avon for a minor PUD amendment for the Buck Creek Lot1A, and per the current schematic design of the Fire Station and Administration Building planned for the lot. Zehren and Associates filed the application on behalf of the District earlier this month. The Town of Avon has done an initial review and today I spoke in detail with Matt Pielsticker who is the Town's Planner assigned to review the application. The Town understands the majority of the requested modifications related to site items, and sees no problems with these at this stage in the process. Per the town's staff initial review, Matt indicated these items will be addressed during the development review process, further down the line, along with more specific plans. There is one item in the application, the encroachment of roof overhangs into setbacks for the Administration Building, that needs to be addressed via a PUD amendment process, and will require Planning and Zoning Commission and Town Council review since it is not allowed per the current development code. The process will require public notice before the scheduled meetings. There are only a couple of additional materials required in support of the application beyond what already has been submitted. These are: 1) A revised Sheet 1 Cover Page of the Buck Creek PUD Development Plan with an additional note (under General Notes section) that is specific to the roof overhang into setback condition of the Administration Building. Matt suggested this new note be similar to note 7. for two buildings in Lot 3 (Walking Mountains). 2) A revised Sheet 2 with the updated site plan for Lot1A, consistent with the current building and site layout as reflected in the current application materials. Matt indicated these displays should be prepared by J&K, Inc, and to be consistent with the sheets that are part of the PUD guide. After receipt of the two items, public notice will be issued, and then the first hearing can be scheduled. We discussed the hearings with Planning and Zoning Commission and Town Council will be an opportunity to update both Boards on the status of the District planning and design, and beyond the current PUD development pian. I also mentioned that it has been the District's intent to do such an update as part of their planning process. I have copied Glenn and Gary at Alpine Engineering to apprise them of the project status. I will coordinate with them further toward the preparation of the two revised displays referenced above. Matt and I discussed attempting to schedule the hearing with the Planning Commission in mid to late September / early October, based on the timing of the delivery of the additional items. Please call me if you have additional questions as part of moving the process forward. Thanks for the opportunity to assist you with this process. Regards, DEVELOPMENT STANDAR DS Lot 3A Public Use (a) Intention. To provide sh.s fora fire -don, lire dbtr ca fadhde, and employee housing -tts. (b) AllowedUses. The following uses shelf be allowed on lot IA 1. An uaes custonartlyamodated with -am branch Am.Bon Including but not heated m truck bays, duty quarters, oHsccus. admini-clan, meeting and ualning roams.; 2 Employee housing uNn for fire dktrica ampleyees; and 1 The Zoring Administrator may approve additional uses found to be similar in nature antl Intent to the Allowed uses () Specbl Review Uscs: I- None (d) Devdopmcm Standard. L Mavdmsm BNlding Heigh. forty 8ve (45) feet with an alawrd arthlm,.r.1 projection for a on a fire station to be fifty -low 155) fcec; 2 Mlnlmum building t.back. The buildng-eltulls Ophaed on The PUD 0".l rrem Plan Map for Lot IAshal1 onsthutt a buidng...I pas that shall -m plat. and Indepm&car of any fuare changes -the Notdngbae Road, Swell Gukb Road or Buck Creek Road Rights 01 Way.; 3. Density. Employee UNt to Serve de Fire District. Lot IB Resld..d.1 T-hornes (al lrtention. To provide sire for residential dwelv,g mads. (b) Allowed mus. The (olowing uta than be per.hted On for IB: D. Resldentiil dv.dhng uralµ l:hd.ding single family, duple and trnnVouses. (c) Special review uses: L Home Occupation (d) Devd.pmrnt,undud. I. Maximum Building Haigh. forty -aro (42) feet 2 Minimum building setbacks: prase Lwemy.rke (25) to. Side: seven and one-half (7.5) feel and Rearten (10) f. 3. Maximum dweling unit she 2.700sf.. gams floor area: 4.M.A.um &,sky: 11 dwdling.Ilu: 5. Bugdng ConRgundon: No more than ch- dwellng .,its per buildng Lot 2 ReddentLd Tewnh---s (a) Intention. To provide sole for midemtel dweileg unix (b) Allowed -a-The I9ILowipg wet shag by permhmd m kn 2- 3. Rende,mal dmlhng unit, including single fanvly, duplex and townhourm (c} Spedal review uses 1. Hoax Dccupadem (d) Devefepinem -dud,. I. Maxrrnlan Hulking Heigh. lorry -two (42) fee. 2 Minimum building setback. Front, Oventy4ro (25) feet: Sid. seven end orc4,.K (7.5) feel and Rcue ten (10)1FN L 3. Ma rnum dwelling.. slot 2700 s.f. gross floor -a;4. Maximum &h, 31 dwelhng unh-: S. $uildng Cnn%..don: No more than three &,Nang units per buildng Loci Naverai Selectce Educatied Faelliq (a) Intention To provide rhes for eduotloW hdlftes and employee hou i,g ,it, supporting the bcil les. 4b) Allowed Uses. The lollowlng was shat be allowed an lot 3: I. Shco.ir. k Empl yet, Housing Unle; 3. Pedettrhn paths and malls: 4, public assembly hdhd.; and 5. euman Muss d public ed..O.,A f.Y*dNa r')Spedal Renew Uses: 1. None (dl Devdopmele standards: I. M-rI.- Building Hdght thlrrycaht{3E) f h 2 Mlnlmum bulld,gmNF: r. Front, -y-firm(25) fee. Side: seven and..A.If (!.S) feet and Rea ten (10) feta Lot 4 PubYc Use (s) Allowed wet. The following uses shall be -Ibwed an Lm 47 1. Undeveloped or Open Space; 2 Erosion p -don strucwres: 3. L ndsoping and .-I t,& 4. Rwd Right of Way: S.Pedemrien crag. and 6. Bicycle paths. (b) Special review aces, I. Non (c) DeveloprT.-tand¢r6r 1. Mlnlmum lot she. Nk 2 M-umhum building heWx Nil 3.Mmi.t. buildng utbacka Nat; 4. M-1- she average IJ7v; 5. Midmum hndwpe area NA ane IS, Maximum density. NA Lot 5 Early Chlldho.d Educatmns, Day Care and Office (-} Intention: To provide a she for early chlld care education and.0ke space. (b) Alowed User The rollpw ing uses shat be allowed on Lot A. I. Early Childhood Eduration {stud- 2 Day Cam Facilities; and 3. Pre kndonl OfBco. {) Special Review Uses: 1. None (d) Devdopmem Sohdards: I. M2,dmum Building Height s"1 (30) fee. 2 Mirtar-Buldi-M Sech.d. Front- fifteen (15) fee. Sldc seven and one half (7.S) feet and Back cm (l0) feet la) Maxim.. Deraly: NA I. Office: 3.000 sgaa . feet mss and 2. Dayan: 21100 4-r. lees mar PARMG LOT IA Lot IA vera Adminsmtlm Building 14 omployeespacea and 23 spaces for Aslan and he .has Fee Daat[Uses:ttesrenea' general public. ,rave -i rt; uYla "12- IS enpleye-Al udlhe he building and tenets. District and he gest Mr '*I:t vel muca.'m G-.1 Publlc" Rre Soden 11 spaces will be pmm&d for the en duty crew, "The crew is on duty for Fmragr 4n,ats;-e: 46 hours and can pa,k in a soder arnngenent' Let 15 lM1tppbs Sruta.meal Resldemial T -home, 2 sp-ces per.niL wh4n 2 car garage Dmvt P,elevet OXY ONe recedes; (2,707 sf-400 d = 2.$00 d unh for p-rkmg cak) 2 guest spaces in frost of eah gamgn Lot 2 Iik no, W'gxf 'ma. rdrahr. Residemtil T-II..ts 2-puea per milt -shin tear garage {2,700 d-400 sl = 2,300 f.rat for parking c.k) B gcla inti psaahan paha: 2 guest spaces M from of each gange Lm3 Gare Range Nawrd Scknce Schaal School Function I sp=deepleyet z 15 employees r,15 spaces Discovery Hof (Museum) 4 spaccsJIODG sf x 1100 s1 e 4 spaces Conerunaty Hill lAssembly) I space/4 seats A 90 seats = 23 spaces Nose: The com.unlq hal{ AAI rax be u+td for funcdons a the same same n school prIegnsm. The Cama.." Hall will only be filled during the evening-, and by agreement, the GRNSS would uolhe up to 9 Let Five perW g spaces in the evenings when anembfy cvmn arc held In the C.-nhy Hall. Tod Perking Kvquim-= 33 pa h,g spaces Nolo: As any as 6 employees w11 be housed on see and h ti anticipated not Al 41 awn a -chicle. 3 gangesp.as and 3..,ad. spaces are pr.,W d for -ply.. at the graduate flews• raFid-,.leaving a req.lrement of 27 spate- In she --in park, g I.. Lot S Day-cve Fclky 2/1000 six 18000- 6 spam Ogke Space 311000 d x 3000 en 9 spaces Tod Total =15 spaces BUCK CREEK P.U.D. P.U.D. DEVELOPMENT PLAN EXHIBIT A TO ORDINANCE 09-08 LOTS I, 2,3 AND 4, WILDWOOD RESORT, A RESUBDIVISION OF LOTS 5, 52A, 52B, BLOCK 1, BENCHMARK AT BEAVER CREEK LOCATED IN SECTION 1, TOWNSHIP 5 SOUTH, RANGE 82 WEST OF THE SIXTH PRINCIPAL MERIDIAN, TOWN OF AVON, COUNTY OF EAGLE, STATE OF COLORADO g ,a�lv SITE �r GRAPHIC SCALE [IN FEET) l-`- - --masrazn ,..ire Ilnch.lee0k General Notes I. This PUD Developmem Pion contains she development dandards and - for the Buck Creek PUD. Other uses and pre viens of dile Town of Avon Zomng Code IWt speciFe ly addressed harem, or M the related apreem m shall apply to the Bock Creek PUD, Z The Town U Avon Design Review Guldd-, (as -cncl d Iron dint to dee) ehA govern devd.p n.. within the Huck Creek PUD. 3.Property ewneM within the PUD steel lsoc have the rfght of refuel agaWver. t SuPUD amendments other dean their existing rights as adjacent property owns. 4. The building footprints shown on the FUD Development Han are schematk. but servo to Illustrate she intent If the decelop.ent pian. It shall be-empuhte to adjust she hWidir%locations and general c rLR ntims s%hdywlthout rvpldng a PUD amendment If welding kpdots must change more than Yen (10) feet In any direction but she Knenl intent of the development pian is maintained, a minor FUD amendment procedure - be followed. The pro ccs- shelf indude she (dewing: a. The PUD Development Flan sheet that htdlnres the lot where the change or changes are to occur will be..defied and s.behitced to the staff for a reA-. b. If the changes are miner and nc�immtd the erlalnal derelapmem plan arc adhered W the non shil baAe she amhoriry+o approve+ase amendment admiradrathdy. 4 Reductions in densly alnl be c.nsitleretl minor and sable.. N still approval d. Changes in use.., Increase In density. shat bsatr a formal PUD a.tndment process. S- N k Crack PUD shall be allowed the following d"dom fan the Town .1'A- M.nkip4 Code Thl. 16 standards: L AMC 16.40.050 (4)-CsWd S a Exemption to slow an Increase in the maximum cut- am length from LOW lee, to app.A-Lelyl,650 fees for Buck Crack lane. to -low the number o7 maidential oohs served by a cd -d- to be Increased Rom 20 to 32, and to allow eom.erdah assn u shown on the Buck Creek PUD Devclopmont Phan. b. AMC 16.40.070-Roodwry Waddl E.-pti n to -low the ro-dway widths w4th, the R.& creek PUD. which sb.11 be el -V ed oo kcal streets, to be nduced from the minimum 22 feet 1.20 fees along their entire length. The Interior roads whhln Loo I B and 2 are nos d -lied as -1-ys but are chsdlled u private drl*- and therefore not rvbiem+o AMC madmy width requirenlcnt. a AMC 16.40.070 (ax2}Grade C. -and V. Dhnnces Exemption Is to anew the maxim.. glide for dlsn- egwl to the napping sight dstnce from ImImran-ed e.ealon be from 6% to 63% for the toot- ,caL sad through Lon IA and I B. d. AMC 16.40.079 (.)(2}Godes Curves and Sight Deem - Exemption isto allow die maximum grade of 4.0% be decor sed from fifty (SO) feet loom ehe lncenectlen to 45 feecen Lor JA and deermsed to 27.5 Poet on Loc 1. e. AMC 16.40.060 (a)-Gndus Cwver and Sight Dhuncec Exemption Is to allow the maximum roadway gra& for Buck Credit Lanc which as dm-ified as e Boal street be incnaed from 8%ro 85% from Session I-90 to 4-I5. to 8.18%hem Solon 6+60 to 7-75, and to 85% from Soden 10+,40 to 11.50. The Buck Creek Lane-ta,ning Is measured starting Ire. hs southern mast tenNnua a -hewn on the B.* Creek PUD PmIlmirnry Construction Plain datedjar.ry 7009 and prepaed by I&K, Ina L A Can m m Ain Aeadwq Maimanance Agree.- will be d hed and svbn*%d to she town of Avon for mysexr and app -L The approval shelf not be subject to conditions that ue not sinni,r in maws to other sirriler agmemere: approved by she sown, low shat -,.I. haguage a ipuhting the on.1-ranee resp-ibilNes ter all -dway. udky. and drainage iMrutrucorrn. Looements will be panted AI,Afkg the Town to rminu, w said ter-crt IF the primmance e aimeIs found to be Inadeq ---e and a cost recovery agnantntfor Town maintenance Mn ub be smlced along -M the required... ants. 6. All lets F*Nn due Buck Creek PUD shall be subject to the Wowing sand Use redricssent, a.axi Mmum Building Lot C. -rt' Fifty percent (50%) b. Minimum Landscaped Area: Twenty Ft. Pancem(7S%) 7. Two hulidings m Lo[ 3 shil be -Bowed eo enerearh inea the stream setWck as gmerdy lndkated on dile development pl-n Thd encrnachmencshali be only gnntedm buddmgs owned by tit Con Range Nawral 5cknce School and to tem a educate III- nparbn habitat and the stunt environment B. A shared puking reduction shill be do." between Leo 3 and 5. Up to 9 specas of p.Rtng on Im 5 an be cant+duad to provide for a portion of she assembly occupumq on Lot 3 for .wring programs provided tsar devdepmam haz been c.nswcree on LotSwhen the prognmsmmmmce. Norhingin dos prevhien shil require theowneref Lot S to develop orconswct curry ecilty or p-r{dnglm Fading etaederds (aril km "K be prrn.ant to the par5dn9 standards dr -W, on drh shm 9, The roof overhang of the Admmidraeon Building on Lot IAshd he allowed to encroach into the 25' front setback and the root overhartgs of the Fire Station f6uilding on Lot IA shill be allowed to encroach ins the 25' Irons setback and 7.S tide mbsdn. 10. The path on+he west side of the Adminhtwi- Building on Lot IA will be lowed to c -,h Into the 30' Riparian Buller Zone as represented on Sheer? LAND USE TABLE LOT IA LOT IB vera LOT3 LOT- LOT .has Fee Daat[Uses:ttesrenea' payn,e) the. ,rave -i rt; uYla Elvawn Fadi n: gest Mr '*I:t vel muca.'m Ite-eiuda twcaq j..sterinl5'".-nd(WONt.yY+a•uly. -ab Fmragr 4n,ats;-e: land-capa utl5a0anag� fell lea; IbrdeeEoerdrpelYadthako'Nt lM1tppbs Sruta.meal :hmcpser lav4ixmea) 1`e,aNwlpaae cue TMs Dmvt P,elevet OXY ONe recedes; E,rp. �,s }eYerp Irl'-' PIEYC Asumhj FttlAEe,' Iik no, W'gxf 'ma. rdrahr. P,ble:xitN/bor=es: Rauana a-1 Atli Educator B gcla inti psaahan paha: Accn-.ry eF N- std ata •aches Orera'fa:- Uea None 3c4e Dainelnn Iiee O,cupach sloe Woe 14a'e ❑eaYY', ESRgmtrF.x roEmelae Fre OnrG 'I o.mhry Lain...,, al pne Ng.nr-r wah, -W'Fahauequta-a _ NA rVA POA.^9 fy uhds mio d Go. pwt ramal sdel.eduod II.MnEMWt bei, FE le 6i as ty cava tel) Int WF t..Axl l.q Iti+y pSa t]81 N'A sty ;3Ll rad Ahen Fd -w... cnimtion wtmwaa it.)-foe1 ,tea Smt.ka� Fns. Ya -s0. MI Fa.t h' yG 05)%at t KA I-tamty.Ywt.,- .,et, cera ern oxiall R.5lkn aide. err. este ox-help.5l fee Ste a- wq"""ft.S:M :de:anenaM cle#eMR,Slded 34c-ae�aM hlRf.ea'R.'+•: tees Nn It r. Imltdl Yat Aar awl stay res Rea -:en llnlsaa rine]-'.Y tretane Hunan pxolry OnS - /.4 1+am PMl.g µrt- Z700peaagaembda 2700 Rw,s agwa ked brt-ee•mnSMnYvq lin rya hlnanmI-31-"ta sa par BUI R."19 Exhibit C J&K, INC. ARCHITECTURE CML ENW LEERING LAND SuRUEYING MAPPING PLANNING STRUCTURAL ENGINEERING POST OFRCEBOX 409 1296 CHAMBEPS AVE- SONE 200 LA"LL COLORADO 81631 P 970516 6168 F 970319 [035 V✓ 4K4NCCOM Rmyca'(F �1 F 2.1 LU Y � W 0. w O f� U W Y �( Z CIO Q fi 8085 TRACT BUCK. CREEK P.U.D. P.U.D. DEVELOPMENT PLAN EXHIBIT A TO ORDINANCE 09-08 LOTS I, 2,3 AND 4, WILDWOOD RESORT, A RESUBDIVISION OF LOTS 5, 52A, 52B, BLOCK 1, BENCHMARK AT BEAVER CREEK LOCATED IN SECTION 1, TOWNSHIPS SOUTH, RANGE 82 WEST OF THE SIXTH PRINCIPAL MERIDIAN, TOWN OF AVON, COUNTY OF EAGLE, STATE OF COLORADO Exhibit C GRAPHIC SCALE (IN FEET 1 J&K, INC. ARcHfrECTuu CML ENGINEERING LANDSURYEYING MAPPING PLANNING STRUCTURAL ENGINEERING PPS[ OE310E BOX 409 1186 CHAMBERS AVE. SUITE 10P EAGLE COLORADO 8[631 P 970 318 6318 F910328 103S WNJK,!NCCOFI P r I R6W9r II a UE I ❑ CL ❑ Z d LL1 Lu 1L Lu 1L LL O ULu LLI U ❑ ❑ m ❑ d nnrmr 6085 2 i SITE AREA C LATIONS TOT�WE AREA 1001%6/94,56637 F TOT L BUILDING A A = 18%116, 6 F� TOT IMPERVIOUS REA = 56° 634 SF /� 4 ♦ ` TOTA LANDSCAPE 0 E CE AREA = 44%141,933 SF 000* ' r _ i ' / 7 LEGEND HARDSCAPE AMENDMENT APPROVED PUD PLAN AMENDMENTS Exhibit I 51TE PLAN I I 0 IV w 4V 1 `� ` ♦ G� SCALE: 17----20' Staff Report To Planning and Zoning Commission AVON Thru Sally Vecchio, Com Dev Director c o i- t, x .> o 0 Fr Matt Pielsticker, Planner II Date October 4, 2011 Meeting RE Special Review Use Permit Amendment Mountain Montessori Preschool Summary On behalf of Mountain Montessori School located at 77 Metcalf Road, the applicant, Dominic Mauriello, is applying to amend the school's Special Review Use (SRU) approval from a two year time period to an approval with no time limitation. Attached to this Memorandum is the applicant's written request, along with floor plans of the building. Background The property is zoned Light Industrial and Commercial (IC). Daycare/pre-schools are not permitted in the IC zone district; however in 2004, the Planning Director determined that this use was eligible for a SRU permit, if approved by the Planning and Zoning Commission (PZC), with certain conditions. The PZC granted the school a SRU approval in 2004 with the following conditions: 1. A sign permit shall be required for any signage associated with this use. 2. This permit is valid and subject to review by Staff and renewal exactly 5 years from the date of issuance (September 21, 2009). 3. Except as otherwise modified by this permit approval, all material representations made by the applicant or applicant representative(s) in this application and in public hearing(s) shall be adhered to and considered binding conditions of approval. In 2010, the school re-applied for the SRU permit renewal, and the PZC granted approved with the following conditions: 1. The use shall not be enlarged without prior review and approval from the Planning and Zoning Commission; and 2. The use is approved for a ten (10) year period to be re -reviewed no later than September 7`h, 2020. In March, 2011 the school returned to the PZC to apply for an amended to the SRU permit to allow the school to expand from 20 students to 40 students with an 808 square foot addition. At that time, the recently adopted Avon Development Code (ADC) limited the PZC's review authority to 2 years (with additional time permitted by the Council). The PZC approved the schools' expansion, with the following conditions: 1. The use shall not be enlarged without prior review and approval from the Planning and Zoning Commission; 2. The use is approved and must be re -reviewed no later than May 3rd, 2013; 3. All traffic, parking, and vehicle stacking related to the drop-off and pick-up activities of the school shall be entirely contained on the property; 4. Student enrollment is limited to 40 students; 5. The size of the school is limited to 2,361 square feet; and, 6. No special events shall occur during the business day. October 4, 2011 Planning and Zoning Commission Meeting Page 1 of 3 In August, the Council amended the SRU regulations; returning all review authority back to the PZC with no time limits on PZC approvals, but (§7.16.100(f)) stated that PZC may assign a shorter time as deemed necessary. Today, the applicant is requesting that the PZC amend its March 2011 approval to allow the school to remain on at its location without any time limits. Property Description The Mountain Montessori space is located on the bottom level of a three story industrial/office building on Metcalf Road. The property measures approximately .89 acres, and is located approximately 200' north of the intersection of Nottingham and Metcalf roads. Public Hearing As required by the ADC, this application requires a published public hearing with the PZC. The notice was published in the Vail Daily on Friday, September 23rd. To date, no public comments have been received regarding this application. SRU Review Criteria When rendering a decision on this amendment request, the PZC shall use the following review criteria as set forth in §7.16.100(e), Review Criteria, ADC, as the basis for a decision: (1) The proposed use is consistent with the Comprehensive Plan and all applicable provisions of this Development Code and applicable state and federal regulations, (2) The proposed use is consistent with the purpose and intent of the zoning district in which it is located and any applicable use -specific standards in the Development Code; (3) The proposed use is compatible with adjacent uses in terms of scale, site design, and operating characteristics; October 4, 2011 Planning and Zoning Commission Meeting Page 2 of 3 (4) Any significant adverse impacts (including, but not limited to, hours of operation, traffic generation, lighting, noise, odor, dust, and other external impacts) anticipated to result from the use will be mitigated or offset to the maximum extent practicable; (5) Facilities and services (including sewage and waste disposal, water, gas, electricity, police and fire protection, and roads and transportation, as applicable) will be available to serve the subject property while maintaining adequate levels of service for existing development, and (6) Adequate assurances of continuing maintenance have been provided. Policy Review A Daycare/preschool use is not permitted as a SRU in the IC zone district. Staff therefore recommends that the use continue to be approved for a limited period of time. If the PZC wants to approve this SRU without a time limit, Staff recommends that the IC Zone District be amended to allow Daycare and/or Child Care Center uses as SRU's. Zoning text amendments may be initiated by the Town Council, any property owner, or any registered elector within the Town. Recommendation Staff recommends approval of Resolution 11-09, thereby approving the SRU permit for the Mountain Montessori School in Suite 101, Lot 22, Block 1, Benchmark at Beaver Creek Subdivision, subject to the following conditions: 1. The use shall not be enlarged without prior review and approval from the Planning and Zoning Commission; 2. The use is approved and must be re -reviewed no later than October 4, 2021; 3. All traffic, parking, and vehicle stacking related to the drop-off and pick-up activities of the school shall be entirely contained on the property; 4. Student enrollment is limited to 40 students; 5. The size of the school is limited to 2,361 square feet; and, 6. No special events shall occur during the business day. Exhibits A—Written request B —Resolution 11-09 C — Floor Plans October 4, 2011 Planning and Zoning Commission Meeting Page 3 of 3 Construction & Development Advisors DATE: August 29, 2011 Exhibit A Memorandum TO: Town of Avon Planning & Zoning Commissioners TOA Planning Staff FROM: Todd Goulding RE: Mountain Montessori Preschool SRU Revision Following Town Council's August 23, 2011approval of Ordinance No. 11-10, Series of 2011 allowing SRU's in perpetuity, Mountain Montessori Preschool is requesting a revision to the existing SRU, approved May 3, 2011. Please accept this letter as the formal request to amend the current approval to have no expiration date. Also, due to the current interpretation by the Town's Legal Counsel, I will not represent Mtn Montessori to avoid any perception of influence. Therefore, I have asked Mauriello Planning Group to oversee the process. If you have any questions please don't hesitate to contact myself directly. Sincerely, Todd Goulding Todd Goulding Construction & Development Advisors CC: Dominic Mauriello (MPG) PO Box 8266, Avon, CO 81620 970.331.1732 tgoulding@cda-co.com Exhibit B TOWN OF AVON PLANNING & ZONING COMMISSION RESOLUTION NO. 11-09 A RESOLUTION APPROVING AN AMDENDMENT TO A SPECIAL REVIEW USE PERMIT TO PERMIT MOUNTAIN MONTESSORI PRESCHOOL TO OPERATE WITHIN SUITE 101 ON LOT 22, BLOCK 1, BENCHMARK AT BEAVER CREEK, TOWN OF AVON, EAGLE COUNTY, COLORADO WHEREAS, the Planning & Zoning Commission (PZC) of the Town of Avon approved Resolution 10-04 on September 7, 2010, approving a Special Review Use (SRU) permit for Mountain Montessori Preschool to operate in the Industrial Commercial (IC) zone district; and WHEREAS, at their regularly scheduled meeting held on May 3, 2011, the PZC approved Resolution No. 11-04, approving an amendment and expansion of the square footage of the Mountain Montessori unit with the following conditions: 1. The use shall not be enlarged without prior review and approval from the Planning and Zoning Commission; 2. The use is approved and must be re -reviewed no later than May 3`a, 2013; 3. All traffic, parking, and vehicle stacking related to the drop-off and pick- up activities of the school shall be entirely contained on the property; 4. Student enrollment is limited to 40 students; 5. The size of the school is limited to 2,361 square feet; and, 6. No special events shall occur during the business day. WHEREAS, the Avon Town Council approved Ordinance 11-10 on August 23, 2011, to clarify the duration of SRU approvals and the authority of the PZC in such approvals; and WHEREAS, Ordinance 11-10 amended §7.16.100 (f) Duration and Expiration, Avon Development Code (ADC), grants the PZC authority to approve a SRU permit in perpetuity, but may assign a shorter time as deemed necessary; and WHEREAS, Dominic Mauriello ("the Applicant'), representing the owner of the property, BBG Holding Co, submitted an application to modify the Mountain Montessori SRU permit, currently valid until May 3, 2013, to operate in perpetuity; and WHEREAS, at their regularly scheduled meeting held on October 4, 2011 the Planning & Zoning Commission held a public hearing to consider approving and amendment to the SRU permit to operate in perpetuity; and WHEREAS, the Planning & Zoning Commission of the Town of Avon considered the following review considerations, as required by the §7.16.100(c), ADC: (1) The proposed use is consistent with the Comprehensive Plan and all applicable provisions of this Development Code and applicable state and federal regulations; (2) The proposed use is consistent with the purpose and intent of the zoning district in which it is located and any applicable use -specific standards in the Development Code; (3) The proposed use is compatible with adjacent uses in terms of scale, site design, and operating characteristics; (4) Any significant adverse impacts (including, but not limited to, hours of operation, traffic generation, lighting, noise, odor, dust, and other external impacts) anticipated to result from the use will be mitigated or offset to the maximum extent practicable; (5) Facilities and services (including sewage and waste disposal, water, gas, electricity, police and fire protection, and roads and transportation, as applicable) will be available to serve the subject property while maintaining adequate levels of service for existing development; NOW, THEREFORE, BE IT RESOLVED, that the Planning & Zoning Commission of the Town of Avon, Colorado, hereby approves an amended SRU permit for Mountain Montessori within Suite 101, Lot 22, Block 1, Benchmark at Beaver Creek Subdivision; SUBJECT TO THE FOLLOWING CONDITIONS: 1. The use shall not be enlarged without prior review and approval from the Planning and Zoning Commission; 2. The use is approved and must be re -reviewed no later than October 4, 2021; 3. All traffic, parking, and vehicle stacking related to the drop-off and pick- up activities of the school shall be entirely contained on the property; 4. Student enrollment is limited to 40 students; 5. The size of the school is limited to 2,361 square feet; and, 6. No special events shall occur during the business day. ADOPTED THIS 4t6 DAY OF OCTOBER, 2011 Signed: Date: Chair: Chris Green Attest: Date: Secretary: Scott Prince 9M-na-oea zsie omaowoxw.v oroa anmary «w Exhibit C aam ONIMH Das NOISNVdX3 K073 0211H1 J7VO13W LL 13S NOIlMAiSNO w A� LL 9910—SY6—OGfi OZ 918 OOtlL'(l'gJ '.. Otl.N llbJ13W GGW , yryrs� b tlt10'J 9NIOlJM 'J99E g� NOISNVdX3 ?JOO-H QaIHI �VO13W LL 135 NOI10f1 fl-SN00 x r5 E w 1351 sera-sre-oes zero oavao-im 'r v avow nVo " tmo f '$s 1103 awaMH aee g $ ` NOISNVdX3 8001� GNIHl 33VX1 VW ZC 13S NOiiomJiSN00 Staff Report To Planning and Zoning Commission TI, Thru Sally Vecchio, Com Dev Director t' 0IORADO Fr Matt Pielsticker, Planner II Date October 4, 2011 Meeting RE Special Review Use Permit Amendment Walgreen's Drive through Summary On June 21, 2011, the Avon Planning and Zoning Commission (PZC) approved a Special Review Use (SRU) permit for a drive through pharmacy window for Walgreen's Pharmacy located at 15 Sun Road. The SRU was approved pursuant to the now amended §7.16.100(f), Duration and Expiration, Avon Development Code (ADC), which limited the PZC approvals to two (2) years. The applicant is therefore applying to amend the two (2) year approval, to allow the use without a time limit. Attached to this report is the Applicant's written request, along with a site plan of the development. Background At the time of approval, the ADC limited the PZC's ability to approve permits for periods greater than two (2) years, but did allow the Town Council to approval longer timeframes. In August, the Council amended the SRU regulations; returning all review authority back to the PZC with no time limits on PZC approvals §7.16.100 (f) Duration and Expiration. Special review use approvals shall expire pursuant to this section. The PZC may approve a SRU permit in perpetuity, but may assign a shorter time as deemed necessary. At least thirty (30) days prior to the expiration, the holder of the special review use approval may apply for a review hearing before the PZC. The PZC shall review the use against the criteria in §7.16.100(e) to determine whether the special review use will be allowed to continue. The property is zoned Town Center (TC). A pharmacy is a permitted use in this zone district and a drive through is a SRU. Other drive through SRU permits have been approved unconditionally with no time limit (i.e. Wells Fargo), Public Hearing As required by the ADC, this application requires a published public hearing with the PZC. The notice was published in the Vail Daily on Friday, September 23rd. To date, no public comments have been received regarding this application. SRU Review Criteria Prior to rendering a decision on this amendment request for a SRU permit, the PZC shall use the following review criteria as set forth in §7.16.100(e), Review Criteria, ADC, as the basis for a decision: (1) The proposed use is consistent with the Comprehensive Plan and all applicable provisions of this Development Code and applicable state and federal regulations; (2) The proposed use is consistent with the purpose and intent of the zoning district in which it is located and any applicable use -specific standards in the Development Code; (3) The proposed use is compatible with adjacent uses in terms of scale, site design, and operating characteristics; October 4, 2011 Planning and Zoning Commission Meeting Page 1 of 2 (4) Any significant adverse impacts (including, but not limited to, hours of operation, traffic generation, lighting, noise, odor, dust, and other external impacts) anticipated to result from the use will be mitigated or offset to the maximum extent practicable; (5) Facilities and services (including sewage and waste disposal, water, gas, electricity, police and fire protection, and roads and transportation, as applicable) will be available to serve the subject property while maintaining adequate levels of service for existing development; and (6) Adequate assurances of continuing maintenance have been provided. Recommendation Staff recommends approval of Resolution 11-09, thereby approving the request to allow a drive through facility for a Walgreen's Pharmacy, subject to the following conditions: 1. The drive through shall be developed no later than October 4, 2013. 2. If Walgreen's Pharmacy ceases to operate the Drive through window, the permit shall be deemed expired. Exhibits A—Applicant's Written Request B—Resolution 11-08 C — Site Plan October 4, 2011 Planning and Zoning Commission Meeting Page 2 of 2 u Mauriello Planning Group September 19, 2011 Matt Pielsticker PO Box 975 Avon, CO 81620 Exhibit A RE: Walgreens Special Review Use (SRU) for a drive-through, located at 15 Sunroad / Lot 2, Sunroad Subdivision Dear Matt: Trinity-Sunroad LLC, represented by Mauriello Planning Group, is submitting a request to extend the 2 year approval of the Walgreens drive-through based on the Town of Avon's approval of Ordinance No. 11-10, Series of 2011, allowing Special Review Uses in perpetuity. At this time, we are requesting that the previously approved SRU for the drive-through at Walgreens be approved for the life of the structure. We have submitted a new Land Development Application for a Special Review Use. Other than the time frame for expiration, there are no changes associated with the drive-through use for Walgreens. Thank you for your time and consideration of the matter and we look forward to continue to working with the Town of Avon to ensure a successful project. Should you have any questions, please do not hesitate to contact me at dominic@mpgvail.com or 970.376.3318. Sincerely, I4,44_;.. z:_ Dominic F. Mauriello, AICP Principal RECEIVED SEP 1 9 201 Community Development Exhibit B TOWN OF AVON PLANNING & ZONING COMMISSION RESOLUTION NO. 11-08 A RESOLUTION APPROVING A SPECIAL REVIEW USE (SRU) PERMIT AMENDMENT FOR A WALGREENS PHARMACY DRIVE THROUGH TO OPERATE IN PERPITUITY ON LOT 2, SUNROAD SUBDIVISION, TOWN OF AVON, EAGLE COUNTY, COLORADO WHEREAS, Dominic Mauriello ("the Applicant"), applied for a Special Review Use (SRU) permit for a drive through facility for a Walgreen's Pharmacy; and WHEREAS, the Planning & Zoning Commission of the Town of Avon approved the SRU permit on June 21, 2011 for a two (2) year period; and WHEREAS, the Avon Town Council approved Ordinance 11-10 on August 23, 2011, to clarify the duration of SRU approvals and the authority of the PZC in such approvals; and WHEREAS, Ordinance 11-10 amended §7.16.100 (fl Duration and Expiration, Avon Development Code (ADC), grants the PZC authority to approve a SRU permit in perpetuity, but may assign a shorter time as deemed necessary; and WHEREAS, the Applicant, representing the owner of the property, Trinity-Sunroad LLC, is proposing to modify the Walgreens Drive through window SRU permit, currently valid until June 21, 2013, to operate in perpetuity; and WHEREAS, at their regularly scheduled meeting held on October 4, 2011 the Planning & Zoning Commission voted to approve the amendment to the SRU permit to operate in perpetuity; and WHEREAS, the Planning & Zoning Commission of the Town of Avon has considered the following review considerations, as required by the §7.16.100(e), ADC: (1) The proposed use is consistent with the Comprehensive Plan and all applicable provisions of this Development Code and applicable state and federal regulations; (2) The proposed use is consistent with the purpose and intent of the zoning district in which it is located and any applicable use -specific standards in the Development Code; (3) The proposed use is compatible with adjacent uses in terms of scale, site design, and operating characteristics; (4) Any significant adverse impacts (including, but not limited to, hours of operation, traffic generation, lighting, noise, odor, dust, and other external impacts) anticipated to result from the use will be mitigated or offset to the maximum extent practicable; (5) Facilities and services (including sewage and waste disposal, water, gas, electricity, police and fire protection, and roads and transportation, as applicable) will be available to serve the subject property while maintaining adequate levels of service for existing development; NOW, THEREFORE, BE IT RESOLVED, that the Planning & Zoning Commission of the Town of Avon, Colorado, hereby approves an amended SRU permit for Walgreen's Pharmacy on Lot 2, Sun Road Subdivision; SUBJECT TO THE FOLLOWING CONDITIONS: 1. The drive through shall be developed no later than October 4, 2013. 2. If Walgreen's Pharmacy ceases to operate the Drive through window, the permit shall be deemed expired. ADOPTED THIS 4th DAY OF OCTOBER, 2011 Signed: Date: Chair: Chris Green Attest: Date: Secretary: Scott Prince BO,TTQM OF CANOPY TO BE 14-0 MIN ABOVE GROUND TRASH COM AREAERY RECEIVING TOTE — STORAGE ENCLOSURE ,.,,,z 9� PROPERTY LINE-/ d \ o 36'-0" +/- CROSSWALK CONNECTIONS TO ENHANCE PEDESTRIAN O ACCESS 0 WALGREENS 97' d RAISED PLANTER PROPOSED MONUMENT SIGN OQ. Od O tea. -_--- 0---- .�° MONUMENTAL PEDESTRIAN STAIR F 3 w SUN ROAD oo90; CONNECT EXISTING SIDEWALK TO ACCESSIBLE PATHWAY TO STORE ENTRANCE - EXISTING SIDEWALK - EXISTING TRANSFORMERS TO BE RELOCATED BASED UPON UTILITY ANALYSIS & FEASIBILITY ,--A SITE PLAN q� O' 20' 40' SCALE: 1"=20'-0" EXISTING SIDEWALK GROSS BUILDING AREA FIRST FLOOR = 11,385 SF MEZZANINE = 3,893 SF TOTAL GROSS BUILDING AREA = 15,278 SF LOT SIZE = 47,223 SF BUILDING LOT COVERAGE = 24.1% PARKING NET SALES AREA SUMMARY CALCULATION SALES = 8,093 SF MARKET = 900 SF PHOTO = 435 SF RX/STOCK/SERVICE AREA = NOT INCLUDED TOTAL = 9,428 SF REQUIRED = 4 PER 1,000 SF = 9,428/4 = 37.7 SPACES PROVIDED = 38 SPACES, INCLUDING 2 HC & 10 COMPACT SNOW STORAGE REQUIRED = PVMT AREA X 20% PAVEMENT AREA = 22,172 SF - 2,600 SF (MELTED) = 19,572 SF (41.1%) 19,572 X 20% = 3,914 SF PROVIDED = 4,030 SF LANDSCAPING: SITE AREA = 47,223 SF REQUIRED = 20% SITE AREA = 47,223 X 2D% = 9,444 SF PROVIDED = 11,895 SF (25.2%) LEGEND SNOW STORAGE AREA SNOW -MELT AREA ® LANDSCAPE AREA SPECIALTY PAVEMENT N=181 C-100 He Staff Report To Planning and Zoning Commission AVON Thru Sally Vecchio, Com Dev Director ` , COLO R A DO Fr Matt Pielsticker, Planner II Date October 4, 2011 Meeting RE Final Design Follow-up Walgreen's Pharmacy Summary The Avon Planning and Zoning Commission (PZC) approved a Final Design Application for a Walgreen's Pharmacy at the June 21, 2011 meeting. The Design was approved with the following conditions: 1. Further review of lighting that is less industrial and fits more with the Town West standards; 2. Further review of signs that are not internally illuminated; specifically, the monument sign should be externally illuminated. 3. The applicant must address the 2:12 roof pitch; and 4. The perimeter landscaping on the north side of the property must be located on the property and not in the CDOT right-of-way. The Applicant, Dominic Mauriello, representing Brandt Marott of the Trinity Development Group and Trinity-Sunroad-LLC (the Owner), has submitted revised lighting, landscaping, and elevation plans to address the Commission's conditions of approval. Background Because this design review application was submitted prior to the adoption of Title 7, Avon Development Code (ADC), the zoning standards from the former Title 17 — Zoning, Avon Municipal Code (AMC), and corresponding (now repealed) Town of Avon Commercial Design Guidelines (the "Design Guidelines") dictate the design review process. Building Characteristics The building measures 15,278 sq. ft., and is composed of 11,385 sq. ft. of ground floor retail area and 3,893 sq ft of mezzanine office/storage space. The primary building materials include: smooth face stone siding, rough cut field stone siding, preflnished cement board siding, heavy timber supports, rough cut field stone caps, aluminum storefront windows, a membrane -style bitumen flat roofing product, and standing seam metal roofing. The color scheme is beige and medium brown, and the signage is bright red. Pole Lighting In order to address condition No. 1 of approval, an alternative light fixture design is being proposed. The new "Munich" light fixture can be found on Page 10-12 of the applicant's lighting information packet (Exhibit B). There are a total of seven (7) parking/drive aisle lights that would be replaced with the Munich fixture if this fixture is approved by the PZC. The Munich fixture is powered by a High Intensity Discharge (HID) light source (i.e. High Pressure Sodium, Metal Halide) instead of LED bulb. In order to determine if these fixtures are in full compliance with the Outdoor Lighting Ordinance, Staff will review a revised photometric plan if this fixture is are approved by PZC. Sign Lighting The sign designs (location, size, type) were approved on June 21, 2011 by PZC, but the lighting for signs was not approved. The applicant is proposing externally lit light fixtures for all exterior signage. The "W" building mounted sign above the pedestrian entrance to the building would have two (2) down -casting October 4, 2011 Planning and Zoning Commission Meeting Page 1 of 3 goose neck style fixtures. The "Walgreens" letter sign on the East (Avon Road) side of the building would have four (4) down -casting goose neck style fixtures. Finally, the freestanding monument sign would have 4' linear LED scroll fixtures. Roof Pitch Attached to this Staff Report are three sets of building elevations: Sheet 1) Existing approved Elevations with 2:12 pitch on upper sloped accent roofs. Sheet 2) Exploratory roof study demonstrating additional height (approx. T) if all upper sloped accent roof forms were converted to 4:12 pitch. Sheet 3) Alternate proposed plan with 4:12 pitch for accent roof atop the two tower features of the building, and 2:12 roof pitch for larger sloped accent roofing. The applicant's preference is the roof design shown on Sheet 3. The Design Guidelines require 4:12 roof pitch for all commercial and industrial structures. The Commission must determine if the revised plans meet the intent of the Design Guideline requirements. For reference, a roof plan is also attached to this report to help clarify the limited scope of the applicant's changes to the roof form since the last PZC review. The majority of the roof remains flat, with limited roof modulation; especially as viewed from the west and south building elevations. Landscaping A new landscaping plan (Sheet 5) is provided, and the plan is largely consistent with the plan reviewed in June. The trees and shrubs that were previously shown on the CDOT right-of-way have been relocated to a small strip of land just inside the northern property line. This plan addresses Condition No. 4 of PZC approval. Discussion Staff's primary concern with the information provided is the amount and intensity of on-site lighting, and light trespass beyond the property line. The photometric plan indicates that the multiple head, ASI LED pole fixtures located around the perimeter of the parking and drive aisles cast light beyond the property lines. If PZC approves the "Munich" fixture design in place of the ASI LED pole fixtures, a revised photometric plan must be provided for Staff approval prior to the issuance of a building permit. In general, there is more light than is necessary elsewhere on the plan. For example, the five (5) "E" located high on the building above windows on the east and north building elevations are unnecessary given their height on the building and the fact that there are other lights in the vicinity to light the drive aisle. These are Metal Halide fixtures, which are not recommended by the Dark Sky Society. Metal Halide (due to its higher costs, energy use, impact on the environment, and greater contribution to "sky glow') is discouraged in most instances. PZC should focus on consistency with "The style, color and design of the fixtures shall be compatible with the overall design concept and the use of materials for the building and site area of the lighting plan §15.30.040(1)." The other lighting standards can be reviewed by Staff with a revised Photometric Plan prior to a building permit submittal. As mentioned, the roof changes do not appear to comply with the intent of the Design Guidelines. The South, West, and North elevations lack roofline interest. The East elevation satisfactorily addresses the Design Guidelines and avoids the linear appearance of the other building elevations. Recommendation If the design modifications are acceptable to the PZC, Staff recommends that the following conditions be added to the approval: 1. A revised Photometric Plan will be approved by Staff prior to building permit submittal which complies with §5.30.040, General Outdoor Lighting Standards, Avon Municipal Code. October 4, 2011 Planning and Zoning Commission Meeting Page 2 of 3 a. Lighting shall be shielded such that the source of illumination is not visible form the property lines. b. The pole light fixtures located near property lines may not produce light trespass. c. Bulb types and lighting intensity levels will be consistent with the Guidelines for Good Exterior Lighting Plans, prepared by the Dark Sky Society. 2. Roof changes are not approved, and new design options to address the linear appearance of the South, West, and North building elevations Will be provided for PZC review. 3. The applicant will provide Staff with one complete approved plan set for the entire submittal in paper and digital formats. Exhibits A — Letter from Applicant B — Lighting Details C — Building Elevations/Site Photometric/Landscaping Plans October 4, 2011 Planning and Zoning Commission Meeting Page 3 of 3 Exhibit A Mauriello Planning Group September 19, 2011 Matt Pielsticker PO Box 975 Avon, CO 81620 RE: Walgreens, located at 15 Sunroad / Lot 2, Sunroad Subdivision Dear Matt: Trinity-Sunroad LLC, represented by Mauriello Planning Group, is submitting revisions to the design application for Walgreens based on the conditions of approval of the Planning and Zoning Commission's approval of the project on June 21, 2011. The conditions of the Planning and Zoning Commission, along with a brief description of how we addressed the conditions, is provided below: P&Z Condition Applicant Response Further review of lighting that is less CR Architecture has prepared "Building industrial and fits more with the Town Signage and Lighting" which provides West standards. revised specifications for lighting fixtures. The applicant is proposing an LED fixture (AST1-LED) as the preferred pole fixture. As an alternative, the applicant finds acceptable the fixture shown as the Munich Series. Further review of signs that are not CR Architecture has prepared "Building internally illuminated, specifically the Signage and Lighting" which provides signs monument sign should be externally that are externally illuminated. illuminated. Specifications for the signage lighting fixtures are included. The detached sign is also externally illuminated. The applicant must address the 2:12 roof The original June plan provided on Sheet 1 pitch. is the preferred option that we request the P&Z approve. Sheet 2 provides an exploratory option for changes to all roof pitches to 4:12. Sheet 3 provides an alternative with roof pitches at 2:12 and 4:12. This alternative is acceptable to the applicant but is not the preferred option. RECEIVED SEP 1 9 2011 ComMunity Db OIOPMent P&Z Condition Applicant Response The perimeter landscaping on the north Sheet 5 provides a revised landscaping side of the property must be located on plan with the landscaping entirely within the the property and not in CDOT right -of- Walgreens property. way. Along with these revisions, we are submitting a request to extend the 2 year SRU approval of the Walgreens drive-through in perpetuity. This request is submitted under separate cover. Thank you for your time and consideration continuing to working with the Town of Avon to have any questions, please do not hesitate tc 970.376.3318. Sincerely, Dominic F. Mauriello, AICP Principal of the matter and we look forward to ensure a successful project. Should you contact me at dominic@mpgvail.com or u Mauriello Planning Group September 19, 2011 Matt Pielsticker PO Box 975 Avon, CO 81620 RE: Walgreens, located at 15 Sunroad / Lot 2, Sunroad Subdivision Dear Matt: Trinity-Sunroad LLC, represented by Mauriello Planning Group, is submitting revisions to the design application for Walgreens based on the conditions of approval of the Planning and Zoning Commission's approval of the project on June 21, 2011. The conditions of the Planning and Zoning Commission, along with a brief description of how we addressed the conditions, is provided below: P&Z Condition Applicant Response Further review of lighting that is less CR Architecture has prepared "Building industrial and fits more with the Town Signage and Lighting" which provides West standards. revised specifications for lighting fixtures. The applicant is proposing an LED fixture (AST1-LED) as the preferred pole fixture. As an alternative, the applicant finds acceptable the fixture shown as the Munich Series. Further review of signs that are not CR Architecture has prepared "Building internally illuminated, specifically the Signage and Lighting" which provides signs monument sign should be externally that are externally illuminated. illuminated. Specifications for the signage lighting fixtures are included. The detached sign is also externally illuminated. The applicant must address the 2:12 roof The original June plan provided on Sheet 1 pitch. is the preferred option that we request the P&Z approve. Sheet 2 provides an exploratory option for changes to all roof pitches to 4:12. Sheet 3 provides an alternative with roof pitches at 2:12 and 4:12. This alternative is acceptable to the applicant but is not the preferred option. P&Z Condition Applicant Response The perimeter landscaping on the north Sheet 5 provides a revised landscaping side of the property must be located on plan with the landscaping entirely within the the property and not in CDOT right -of- Walgreens property. way. Along with these revisions, we are submitting a request to extend the 2 year SRU approval of the Walgreens drive-through in perpetuity. This request is submitted under separate cover. Thank you for your time and consideration of the matter and we look forward to continuing to working with the Town of Avon to ensure a successful project. Should you have any questions, please do not hesitate to contact me at dominic@mpgvail.com or 970.376.3318. Sincerely, Dominic F. Mauriello, AICP Principal u Mauriello Planning Group September 19, 2011 Matt Pielsticker PO Box 975 Avon, CO 81620 RE: Walgreens Special Review Use (SRU) for a drive-through, located at 15 Sunroad / Lot 2, Sunroad Subdivision Dear Matt: Trinity-Sunroad LLC, represented by Mauriello Planning Group, is submitting a request to extend the 2 year approval of the Walgreens drive-through based on the Town of Avon's approval of Ordinance No. 11-10, Series of 2011, allowing Special Review Uses in perpetuity. At this time, we are requesting that the previously approved SRU for the drive-through at Walgreens be approved for the life of the structure. We have submitted a new Land Development Application for a Special Review Use. Other than the time frame for expiration, there are no changes associated with the drive-through use for Walgreens. Thank you for your time and consideration of the matter and we look forward to continue to working with the Town of Avon to ensure a successful project. Should you have any questions, please do not hesitate to contact me at dominic@mpgvail.com or 970.376.3318. Sincerely, Dominic F. Mauriello, AICP Principal BUILDING SIGNAGE & LIGHTING 134- 4' T/TOWER CHANNEL LETTER SET TkTR EXTERNAL WOU41ED C005ENECK LWRNG PREFINTSHED CEMENT BWD t5+ 906 7/MASONRY PREFWISNED STANONG SEAM METAL ROWNG. lml TYP HEAVY TIMBER FRAMNG ADDRESS ABOVE DOORWAY 100' 0' FIv SHED ROOF ROWK CUT FIELD SWHE STI • 7 - -i4 MCN -ILLUMINATED -1 CHANMEL LETTER SET WTMEXTERNAL M"WED GCOFEFIECK LWHTING PREnNISFiEi7 5M001H FACE 5i2 STONE UNITS 1 1� •� ■ MEN ......... . ■ ■ ■ ■♦ ALUMINUM STi$tEFRONT •MNDOWS ♦ • • • ARCHITECT DESIGN EAST ELI SCALE: 1/$SCALE: =F -D -D Walgreens -Avon, CO CR Commission No.: 511017 September 14, 2011 Page 2 of 12 c:� www.cr-architects.com W il LIGHTING Availability Arm Dimensions Shade Dimensions Color Options Arm Extension Shade Max Wattage T 7.5• � 14 1 �--24.7� A E 3 ff C N Usually ships in 1-2 weeks. 24.75" W x 14" H 12" Diameter, 12" Height C51 Arch Bronze AE3 ANG812 Incandescent Bulbs: 20OW Florescent Compact: 26, 32 or 42W* HID (MH and HPS): 35, 50, 70 or 100W* Call 888-919-7446 for ballast options Approximate Sign Coverage 4-4.5ft Arm Dimensions: 24.75' W x 14" H ;7.5" Radius, 5" bottom wall mount to shade mount Shade Dimensions: 12" Diameter, 12" Height Walgreens -Avon, CO CR Commission No.: 511017 September 14, 2011 Page 3 of 12 MONUMENT SIGNAGE & LIGHTING rOSIfD OR MONUMENT SIGN SCALE: lleGl'=Q' (TYP. CF 2) • • RHYTHM Flood Walgreens—Avon, CO CR Commission No.: 511017 September 14, 2011 Page 4 of 12 c N www.cr-architects.com 5' (N)x Q' { NI} NST-ILLUlA ATED CHANNEL LETTER SET WAIGR€EH5 NlpiluWIENT STGF! Wf g-, ♦■■■■■■■■■■y�i ■ f EMnERW4'LNEARLED n ILtIW LIGHT :EACH SIX _ ��51[!HG ♦ ■♦ Cir - � REUGH CUT 5fY _ ♦' - '' rirrrj STONE rOSIfD OR MONUMENT SIGN SCALE: lleGl'=Q' (TYP. CF 2) • • RHYTHM Flood Walgreens—Avon, CO CR Commission No.: 511017 September 14, 2011 Page 4 of 12 c N www.cr-architects.com H E UM L dli�4keAh�?3.�:yxk, C�rrydy Tm RHYTHM LINEAR LED FLOOD DESCRIPTION: Hydrol's Rhythm Series is a vorsaol[E and distanctLED-bas•_c range Df linaerflaodlights, providing designers unjimibed aptions tc iI •_ml7a'e and enhance the architecture for interior and exterior app icetiziis. Clean, sophisticated lines bland seamlessly wim architectural elements and create dramaticwashes of lightforspectacuIarEffects. Luminaire designs balance day farm w6 function while incarporat- ing the smallest surface mountable power LED's available today. De si g ned to optimize therm a I ma r ag ement. RhyMm lumina fres deliver industry hest lumen maintenance of 5.0.000 hours life at 815 rr widi M% lumen maintenance. SPECIFICATIONS, MATERIALS: Extruded 6093-T4 aluminum with die castA360 aluminum mounting. All fasteners are stainless steel. LENS: High strength optical grade clear acrylic. MOUNTING: Adjustable Surface Mount ASMI, Side Adjustable Surface dllountfSASMI and Knuckle Mount IKM). SOURCE : (luantity six 115I RebEIT^' LED's per linear foot, criver. a- 6T5 mA, with maximum power consumption of 13 watts per linear foot Lumen Maintenance of individual LED light sources have been independently tested to IESNA LM -80 standards. NOTE LM -90 does not cover measurement of luminaire. POWERSUPPLY: 60W powersupply is providEd sisndard whh NEMA rated enclosure,andmay he remotely located up to 20Aw­1 Two 121 BOW power supplies aed tw'o 121 NEMA rated enclos_res required fare' and T Iumineires.Optional NEMArsted powersLe_•1ies rated to IP66, are avedabla for use with the Rhythm. CONTROL: Available with 0-10voltdimmingopton.Dimming module mounted in SS$R surface box. VOLTAGE: MVOLTIT20-277VlSWfi0Hz OPERATING TEMPERATURE: -40'C t4 50'C DISTRMUTION: 5' Narrow Spot; 44' Medium Flood. 64` Flood,' 1? 2 Wide Flood, and Bq' Wall Wasti Distribution, All photometry tesr_e1 to IESNA LM -79 Standards. FINISH: Black anodized extruded aluminum. See order guide `,F accentcoloropbors- Custom 5rLishos mavbe available upon request. Mounting accessories and surface box are polyester ozve.cer scat. LISTING: CSA, CSAcs WARRANTY. Five 151 year Ii nited warranty. Cansult Factory for details. IP66 NAME .-del Pc rSupo( L€a Elul aft 0a 7011uhane Mounting Mounting Ooors Accessories Cad Set Length 0 ppt�3na-Fi�iah Accera mi& 1314 W?o EN I r� r— eh1-muddle Mount SASM - Side Adjustable ASIA- Adjustable Surface Mount Surface Mount X APPA 0 U.ALS Walgreens—Avon, CO CR Commission No.: 511017 September 14, 2011 Page 5 of 12 C:� www.cr-architects.com RHY 2 RHY 3 RHY 4 RHY 6 RHY B ActuallXJ 24.95" (634) 36.95" ;9331 48.35" (12431 72.95" 118531 96.95" (24631 APPA 0 U.ALS Walgreens—Avon, CO CR Commission No.: 511017 September 14, 2011 Page 5 of 12 C:� www.cr-architects.com RHYTHM ORDERING INFORMATION 60-H hlz Application PART NO. — EXAMPLE: Madel ❑ RHY2 ❑ RHV3 ❑ RHY4 ❑ RHYS ❑ RHYB LEC Calor ❑ WHTM White ❑ Wk%T41K White ❑ WWNK White L] RED Rad ❑ GAN Green ❑ BLU Blue Voltage ❑ MVDLT 12O.277VAC ❑ 12 12VDC 0558W Surface Bax F4101h ❑NRPB, NEMA Powar Supply ❑ UPS' LOBS Power Supply CBPCAB Polymeric Camao Box Aluminum Lid CBPCB' P.nlyrmnc CcmRo Box Brenm Lid c:� I Mounting' ❑ ASM Adjusta3le Surface Mount ❑ SASM Side Adjustable Surface Mount ❑ KM Knuckle Mount Distributions ❑ NSP Narrow Spat ❑ M'FL Madium Flood ❑ FLFlood ❑ WFL Mill; Flood ❑ WWI) Wall Wash Disttihutioli Acc®ssories options External Mounting Options Cord Length' Dimming ❑ EARM Extandad Arrn From EsxWre to driver Whiee Specify length ❑ CSL24 24' of cord 7O 6"12, 118 AWGi Ass ❑ EASRM_ Extended Arm P1HTE. Willi Strut 12". 'A", 24". 3V I Mounting' ❑ ASM Adjusta3le Surface Mount ❑ SASM Side Adjustable Surface Mount ❑ KM Knuckle Mount Distributions ❑ NSP Narrow Spat ❑ M'FL Madium Flood ❑ FLFlood ❑ WFL Mill; Flood ❑ WWI) Wall Wash Disttihutioli Acc®ssories options External ❑ LDiM1 0.10V ❑ HVSR Halfvisor Dimming ❑ FVSR FuIlVisor ❑ ETE End -to -End Accent Finish dntianal ❑RDA Red Accent ❑GNA Green Accant ❑RHA Blue Accant Lison 11 iEC International Eroctrotac hni ca I Commission www.cr-architects.com OBLA Black Arfodi2ad ❑CFA Custom Firl s h Ar:adi2ad LIGHT ENGINE SPECIFICATIONS Notn' LIPS requires remain 12V-r-5%DC Power Supply a! Site H UPS ttt9n 12 •equired. ' Quantity f21, Two Poker Supplies provided with RHYB & RHYB models. ' Tran ill horizontally ad[ustable mounting arms provided with RHY2. RHY3, and 8104. Three 131 arias provided with RHYB and RHYB. ' ft LDIM is ehossin, SSBR required. All fixtures shipped with 24` cord 118 AWG). " For ground mount applicatians only. Walgreens–Avon, CO CR Commission No.: 511017 September 14, 2011 Page 6 of 12 I Whiee REBEL ENO'x 7O a 75.61 Ass X2.56 P1HTE. While R€BEL 410a'K 70 a 79d 950 1258 WNT4tr l AT@o- REBEL 3000'K a5 a Jath 580 12.50 VA17Ux- BW REBEL O27 nm a S3.ta W 13.16 REDI Cwe.n :GRNI REBEL 560 nm a 75.94 ma 12.59 Bluo- iBLLt; REBEL 430 nm a lam 251) 12.56 Notn' LIPS requires remain 12V-r-5%DC Power Supply a! Site H UPS ttt9n 12 •equired. ' Quantity f21, Two Poker Supplies provided with RHYB & RHYB models. ' Tran ill horizontally ad[ustable mounting arms provided with RHY2. RHY3, and 8104. Three 131 arias provided with RHYB and RHYB. ' ft LDIM is ehossin, SSBR required. All fixtures shipped with 24` cord 118 AWG). " For ground mount applicatians only. Walgreens–Avon, CO CR Commission No.: 511017 September 14, 2011 Page 6 of 12 C:� IP66 END-TO-END SYSTEM (ETE) When spiiaifyir.g and -t_-.-,1 IETE) optcr, each luminaire will ship with one Single and one dual mounting configuration, Lnisunng Easc of specification and installation avarytime X Z_ SINGLE DUAL DUAL DUAL SINGLE Refer to lWusing chart oil first papa for acius, lerrgdIff. ETE - DUAL MOUNT DIMENSIONS 4' 3�1 2 KM-Knucke Mount IDUAL) J 41 W SASM -Side Adjustable Surface Vaunt (DUAL) NEMA RATED SURFACE BOX (SSBR) Evc I Dsure Constructio it: Designed to marry the day -form of the Rhythm wall mount plate, the SSSA Power supply enclosure is a wet location housing suitable for surface mounting. The SSBR box is available with side condult: entries or standard with back mounting over recessed OF JT 421,11 splice box. MATERIAL: Copper -free cast aluminum A360. All 1h" NFS JU] i aluminum materials treated prior to aroolizing- FINISH: Black powder coat i custom finishes may be 2W. available upon request. _L_ FASTENERS: Stainless steel tamper resistant LISTING: CSA, CSA, 2' ASM -Adjustable surraoe Mount (DUAL] Walgreens —Avon, CO CR Commission No. :511017 September 14, 2011 Page 7 of 12 Site Light Poles (Labels "A" & "F" on the Site Photometrics Plan) AST1-LED AerisTm LED Suspend Area and Roadway Lighting Intended Use Ideal for parking areas, street lighting, walkways and car lots. Construction Rugged, die-cast, single -piece aluminum housing with nominal wall thickness of .012". Die-cast door frame has impact -resistant, tempered, glass lens (3/16" thick). Door frame is fully gasketed with one-piece tubular silicone. Finish: Exterior parts are protected by a zinc -infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi -stage process ensures a minimum 3 mm thickness for a finish that can withstand extreme climate changes without cracking or peeling. Standard Super Durable colors include dark bronze, black, natural aluminum and white. Available in textured and non -textured finishes. Optics Precision acrylic refractive optics for optimum light distribution through the flat glass lens. Available with Type 2, Type 3, Type 4 and Type 5. Electrical High -efficiency nominal 4000K, 65 CRI LEDs mounted to a metal -core circuit board and aluminum heat sink, ensuring optimal thermal management and long life. Designed to provide more than 60,000 hours of performance (L85) at 25°C (77°F) ambient temperatures. Maximum ambient 40°C (1041F). Standard and dimming drivers are available in 120-277V and 347-480V; 50/60 Hz. Drivers have power factor >90% and THD <20%. Expected driver life is over 60,000 hours, matching the light engine life. Integral surge protection tested in accordance with IEEE/ANSI C62.41.2 to Category C Low. Walgreens -Avon, CO CR Commission No.: 511017 September 14, 2011 Page 8 of 12 C:� www.cr-architects.com Installation Integral arm for pole or wall mounting. C:� Listings CSA certified to U.S. and Canadian standards for 40°C (104°F) ambient. IP65 rated. US. Patent No. D447,59O. Canada Patent No. 94324. WARRANTY: Five-year limited warranty. PERFORMAVE DATA Nola I teAea:W LP, X79-2 sta'slaM : LUN G—E2.1PLATE S B K I_` v_..� Lav G.mirms� ari T a. rR x. eta _uga b a.. �¢ e..cs u.-rs-scn a pan c.s�s ce.• Walgreens—Avon, CO CR Commission No.: 511017 September 14, 2011 Page 9 of 12 '-arci itects.corn jwllli�wl ��000A� Nola I teAea:W LP, X79-2 sta'slaM : LUN G—E2.1PLATE S B K I_` v_..� Lav G.mirms� ari T a. rR x. eta _uga b a.. �¢ e..cs u.-rs-scn a pan c.s�s ce.• Walgreens—Avon, CO CR Commission No.: 511017 September 14, 2011 Page 9 of 12 '-arci itects.corn C:� Optional Alternate Site Light Poles (Labels "A" & "F" on the Site Photometrics Plan) MUNICI I SERIES Large Luminaires EK25RT GCSE SPFCIRCATIONS DESCRIPTION Th e I um na ire sha II consist of a bal last hou s- ing and skirt with internal reflector and horizontal lamp. Lens shall beflat sag, half sphere or drop globe, DIMENSIONS Dimensions shall be as detailed on the back page. MATERIALS The ballast housing and skirt sha 11 be cast aluminum. Ci lobe material shall be clear glass, flat or sag, or clear acrylic: half sphere or drop glob,-. The reflector shall be anodized and segmented for superior uniformity and con- trol. AJI hardware shall be stainless steel. INSTALLATION The luminaire shall have 1.5'f, -male, NPT at top for mounting to the Eurotique 5' diameter arms. The globe shall be gasketed www.cr-architects.com and mounted on an aluminum ring which is hinged to the skirt and furnished with a captive screw for easyrelamping- The ref! ec- tor shall pivot and be secured with a captive screw for Cary access to the ballast plate. The ballast and socket assembly shall be furnished with a quick disconnect plug and mounton a rem ovable ballast plate - El NISH late_ EINISH For finish specifications and color options, see 'Finish' section in catalog. Luminaires shall be fu mi shed with an H. LD. ballast and socket assembly. Luminaireshall bcUL listed and lab, -led as suitableforwct locations. Socket shall be glazed porcelain mogul baser with a copper alloy nickel plated screw shell and centercontact Ballasrshall be core andcoiI, high power factor, regulating ty pc. CERTIFICATION Upon request, manufacturer shall supply UL file* and listing information. PHOTOMETRY See "Eulotique PH OTOMETRICS' t3b in catalog. LU I TI COLI I=' Architectural Lighting Walgreens—Avon, CO CR Commission No.: 511017 September 14, 2011 Page 10 of 12 MILINICI { SERIES Large luminaires EUROTO UI" '1rrht Lural u4hting EM25W, EMEW ' sU �i r�a�CHs ,4m k1'h 'F 3a5'F 31Sk - 18.i� r �EMi2U7 l—) •Em1355T 1 FJA355T �P�+ c�er rc a€ L ern .3h + - EFn25FT DUWT EY35Ft Err25Fr Gly G{5G AfH3 4C6 77"F 26.411 di.5`h 3h31• Fllttiim: y-gliim3 K& a*_ r+ 3S1AlLrn1ivuin Piurnb Hawr1neELr3Uqul-5 Ann) 1.5�Alu nirum SxNEI Nipple(Eui otque' r'Atn)) Stalinless Sed Sett-t.%UcevN Dukk ❑isisan Kr Plug CastAluminum Ballast.. Housing H.I.P. Callas[ Cgrponeri1=. {F coalq R°e.01reai) RmK,able Bdast Plattewith () myhDk slLm and F,3eA5 Casr+Vumrnum Skirt Mick L1lswnnmTPlug hminum ReilKhv, PKvdng H9tli Capke Emw PorlalainMcgul Base 9mket. HirgK �d.1dultinurp Lere Ring Oth C3p1tNa51n�. LenEwiul Qentlruous jaslet a-lRDMING INFORMATION ErompL,E 125PT I6D9P409Gr9G SP2 120 AN of ir. trQ bd.dkn9--arg -31aW �1n yrxrawetlI ead wire n m the r�fecIDap OIr. Q u. 17.1X''47 , ®Fnigh, I I optam; E1.12 --PT MOM MOO 1e5—&FMtdrr,.1dr SM lryanmumn 120 AARK uaee H5 EM2SSi 400M MOts -w Maid HJ= SR3 IKDhtruullan 200 AN PB D.*en_am 4F 3rQa1 EMF2EFT }509 1410E 'ra war• Mard W1j' .311241 IU01FRbur4n 240 ANCA' oalk crxn OF M3mnv-A-P 2505 MCI' "A.'kd' 4P Reeve dna 394W lEa ambumn 277 ANUG �m c1o1x1 4004 MOG 'Ik" 3h ry, Rears -.I— SW6 lINDIF b rkl o 347 ANPP Prru Fdrlud a4 Y.�II M t ae[ere sn'larl 400 CM C.'i m 1 tm TB cs to-3;h- Lemm Vcfa Wl a� rmi•a I tit 9'1 s I'Ij1 >� l.YI 3I7Y y.1 GL[ a4T. 31 Te�J1 z' zArl f = 7 111 ?s<l GCF >k r�Aa Gc3G G.' gti 17 , _3..Ybli it M 9r PdYr it •IdAC A_r_ 3-lidr5l�l'Iec r -T T7_rdb,ass r ,a t,} 19rs 4pF.�rSd�a�tia*�rrt' p ,a=, ACD A.W_ 3aQG.P 5ths Lmet a+rlaw rd �n.z ".v TEM ffi��C� l•p,f 7$" 'r'r'Saxyr�',^" 4�''l�t Walgreens—Avon, CO CR Commission No.: 511017 September 14, 2011 Page 11 of 12 c:� www.cr-architects.com Specifications The nallast housing ana tefiec cr housing st*oO be coat caLrni- t um' seal -welded together for a ore-oece Uri`. Lers mraterial sball be clear fat glass (4 CF), or oleo sag glass ('c.C"aG1. All t,atdware Mag be sta%niess steel. The Iunr* a3re shad hove 34' or EV fe-nale- NPT at top for mounting to *uratkT jaT" arms. The Dens strall be gasketed and moterted on an aluminum ring which is hinged To the Musing and furnished with a captive screw for easy re-lomping. The refilecxor shall hinge and be secured with c captive sc rew for easy access m the ballast plate. The ballast paate shall t•ave S keyhole sots for easy removcab*ty The bm'ust and socket assembly shall be furnished w=th ouicx disconnect plugs. DAM -51011 {jam The Turk -Skies lurninahres utilize the Aeds' reflectors. Lhey are anodrxed and segmemea forsuperiar Lin;Formily and contTal. Reflectors are available in 5 nifferent disttaauticns ate inter- changeoble ani use a harizantal lamp Lurrm rn �es sfizall be furnisher) wnh aR H.I.D. ballast and socketassembly- Luminaires shall be lfL listed and Iabeleo as surtoble far we; lacexions. Sockets shag be glazed porcelai-�, medium or mogul base, with a r copper alloy nic kel-plated screw shell end center contact. Ballasts shall be core and ow, high power factor, regula*ing J -pe. Emm lir' `neat lin sh of the k,,•ninaires shall be powder Boated with a pre- mium TialC payester powder. liefcxe cock ing, the par's shoal be treated wirt a seven stage pre-reotmer* process'ir'rclud- �,g blas!ing. Hec-ec alkaline cleaner, rinse, phosp3uate coaT- ung, rinse. sealant. and a final rinse. Standctd colors are bloc k (AIVRq. dark bronze �AMDB3 . or dark green (ANDS). Custom Selectea colors can be ct+osev {tom a wide se�ectior of RAL odrors +and is represented by (CSS). Custom M€ -cfr is a color to mo'cf' a speclFc Bohai chip or color sample that is provided by the specifier and is represented by (CIV). For more information on finish, see The 'finish' sectoean in the ANTIQUEStreet Lamps caralog or contact A NTIElUE Street Lamps. Walgreens -Avon, CO CR Commission No.: 511017 September 14, 2011 Page 12 of 12 C:� www.cr-architects.com 132-8" T/TOWER EXTRUDED FORM, EXTERNALLY LIT SIGNAGE PREFINISHED CEMENT BOARD — _ �SIDING _ 116'-8" T/MASONRY PREFINISHED STANDING---- SEAM TANDING----SEAM METAL ROOFING, MR1 TYP HEAVY TIMBER FRAMING ADDRESS ABOVE DOORWAY 100'-0" FINISHED FLOOR ROUGH CUT FIELD STONE ST1 100,4'_ V" FINISHED FLOOR 122 EXTRUDED FORM,. - - - EXTERNALLY LIT - -_ - SIGNAGE - - - - - -- - -- sTz SMOOTH FACE 0 STONE UNITS PREFINISHED CEMENT BOARD cs1 SIDING 135-8"_ Ah T/MASONRY IV SMOOTH FACE STONE UNITS ST2 123'-8" Ah T/MASONRY IV 118'-0" T/MASONRY -" EAST ELEVATION - AVON RD 12 PREFINISHED CEMENT BOARD i 2 SIDING CS1 - - - - -- _ =I I - -7 Pf - - - -- n f. \_—ROUGH CUT FIELD STONE ST, WEST ELEVATION SCALE: 1/8"=11'-O" DOMESTIC WATER & GAS ENTRANCE architecture + d e s i g n IXWWVII VVI RLVlflll\VIMI .JIVLI,V� FIELD STONE WINDOWS sF1 ED SOUTH ELEVATION - SUN RD SCALE: 1/8"=1°-0" 05-09-11 CR Comm. #511017 ROUGH CUT FIELD STONE sr� CEDAR FENCING Z 132-8' _ T/TOWER PREFINISHED CEMENT BOARD SIDING CSi 116'-8' _ T/MASONRY PREFINISHED STANDING SEAM METAL ROOFING, TYP MR1 HEAVY TIMBER FRAMING ADDRESS ABOVE DOORWAY ROUGH CUT FIELD STONE ST1 102'-0" T/PLANTER 100'-0" FINISHED FLOOR SMOOTH FACE STONE UNITS sT2 138'-0" T/MASONRY PREFINISHED CEMENT BOARD SIDING cs1 EXTRUDED FORM, EXTERNALLY LIT SIGNAGE 138'-0" T/TOWER IV PREFINISHED CEMENT BOARD est SIDING 123'-8" _ T/MASONRY 12 -_ 14 1` 123'-8" T/MASONRY 116'-8" T/MASONRY 102'- 0" T/PLANTER _ 100'-0" FINISHED FLOOR 133-8 _ T/MASONRY PREFINISHED STANDING SEAM METAL ROOFING, TYP fu_pi�r HEAVY TIMBER FRAMING ROUGH CUT FIELD STONE ST1 1 WI I V Ll 1 V 11L ELECTRICAL SERVICE ENTRANCE 100'-o" _ _ FINISHED FLOOR MATERIAL LEGEND SUMMARY ANNODIZED ALUMINUM STOREFRONT W/ CLEAR sF� VISION GLAZING BY OLDCASTLE BUILDING 6.0 S.F. 0.00 S.F. ENVELOPE. COLOR: MEDIUM BRONZE ROUGH CUT FIELD STONE, SIMILAR TO VOGELMAN STl WEST STONE & MASONRY, COLOR/STYLE: 0 S.F. 0.00 S.F. VOGELMAN BROWN CHOPPED ST2 SMOOTH FACE STONE UNITS, SIMILAR TO ARRISCRAFT INTERNATIONAL RENAISSANCE 0.00 S.F. MASONRY UNITS. COLOR: SUNSET cs1 6" PREFINISHED CEMENT BOARD SIDING BY JAMESHARDIE COMMERCIAL PRODUCTS. COLOR STYLE: CEDARMILL LAP SIDING, CHESTNUT SITE SIGNAGE BROWN MR1 PREFINISHED STANDING SEAM METAL ROOFING BY TOTAL PROPOSED BERRIDGE MANUFACTURING COMPANY, COLOR: CHARCOAL GREY cF1 FIELD STAINED 6" CEDAR PICKET FENCING 108'-0" T/SIGN 100'-0" _ FINISHED GRADE SIGN AREA SUMMARY WEST ELEVATION "EXIT' DIRECTIONAL SIGN BOX (NOT INCLUDED IN TOTAL) TOTAL PROPOSED 6.0 S.F. 0.00 S.F. SOUTH ELEVATION NONE PROPOSED TOTAL PROPOSED 0 S.F. 0.00 S.F. NORTH ELEVATION SEE WEST AND EAST ELEVATIONS TOTAL PROPOSED 0.00 S.F. EAST ELEVATION 18'-4 1/4" WALGREENS SCRIPT SIGN 99.86 S.F. *'DRIVE THRU PHARMACY' DIRECTIONAL SIGN BOX (NOT INCLUDED IN TOTAL) 6.0 S.F. WALGREENS SCRIPT 'WSIGN 43.1 S.F. TOTAL PROPOSED 142.96 S.F. SITE SIGNAGE MONUMENT SIGNAGE 30.0 S.F. TOTAL PROPOSED 30.0 S.F. ENTRY TOWER ELEVATION WALGREENS SCRIPT 'W' SIGN TOTAL PROPOSED 43.1 S.F. 43.10 S.F. TOTAL SIGNAGE PROPOSED 216.06 S.F. TOTAL SIGNAGE ALLOWED 21TOO S.F. ALLOWABLE SIGNAGE: ONE (1) SQUARE FOOT OF SIGNAGE PER ONE (1) LINEAR FOOT OF BUILDING ALONG LOT FRONT. LOT FRONT CONSIDERED FRONTAGE ALONG AVON RD & SUN RD "H) x 6' (W) WALGREENS 2UDED FORM, BACK -LIT I MONUMENT SIGN SCALE: 1/4"=1'-0" (TYP. OF 2) NORTH ELEVATION SCALE: 1/8"= V- 0" nLMV i iimoLR FRAMING -INISHED CEMENT BOARD VG cs1 GH CUT sTi r' STONE PREFINISHED CEMENT BOARD SIDING cS1 PREFINISHED STANDING SEAM METAL ROOFING, TYP MR1 June Approved Plan - Elevations - Walgreens Avon Rd & Sun Rd, Avon, Colorado 135-8" _ T/MASONRY SMOOTH FACE STONE UNITS 5T2 36'-R P/MASOMRY 2 5ez SY00111 FACE PRErINISEO CEMENT BOARD 532-6- NEST ELEVATION AMNOCIZED ALUMINUM STOREFRONT IF/ CLEAR EXTRUDED FORM, STONE EMITS 2 ENKLOPECOLOR. MEDIUM BRONZE SOUTH ELEVATION___ SIDING t5t 5tI T/rDMER AN LOCELMBROWN CHOPPED EXTERNALLY LIT SMOOTH FACE STONE UNITS, SMkAR TO SEE WEST AM EAST ELEVATIONS TOTAL PROPOSED ARRS(`RAFI INTERNATIONAL RENAISSANCE MASONRY UNITS COLOR: SUNSET O57 EXTRUDED FORK __ t5-4 1/4' NALGREENS SCRIPT SIN ''RYE TINU PNARVACY DIRECTIONAL SIN DON (NOT NCLU0E0 N 1OTAL) WALGREENS SCRDI 'W SCN TOTAL PROPOSED JAMESHAROE COMMERCIAL PRODUCTS SIGNAGE P%rRI9E0 CEMENT BOARD - BROWNI M"UEMt SXMAGE EXTRUDED FORM, 1U.LT 111 TOTAL PROPOSED EXTERNALLY LIT _/J�{- SIGkACE CHARCOAL GREY SMOOTH FACE 6Ri STONE UNITS Y;�Z LINO., ! J„' /3.1 ST. 13.10 SF. SIGNAGE a G TOTAL SIGNAGE PROPOSED 216.06 S.F. TOTAL SIGNAGE ALLOWED 217.00 SF, ALLOWABLE SIGNAGE'. DIE (1) SUMARL FOOT O SIGNAGE PER ONE (1) LINEAR FOOT OF BUILONC ALOFK, tOr FRONT, LOT FAINT CONSIDERED FRONIACE ALONG AVON RD OR SUN RD _ PREFINISHED CEMENT DOARO.. - Q SUMOIlk_ CS7 1 _ - ' 123B' T%MASpNRx _ 176'-87 I/MASONR �I - - i.' It6'_6• PREITISED STANDINGr�IIASCNRr SEAM MEIA,LRROO�ORNG. Typ HEAVY TIMBER--=.,,�- � I - . FRAMING ADDRESSABOK -' - - -I s� '(S F•.•, I - . DOORWAr I _ r•'} W, •�, 1') - 1 { '•+Fl.T� t4 f� r/3ANffR -IDD'-O' FIN,_—SHID RppR RDLERI CUT ALUMINON STOREFRONT -- rf�p SCCUT FIEED 53 WNDDNS EAST ELEVATION - AVON RD , Ras•-B- T%MA5CNA'Y PRETiNISTED C[L[NT DMRC SMOOTH FACE - 9DMG Ose SICK UNITS 0 1 — SMOOTH FACE SICK LIMIS f:r2 Spa -O' FAUSHEO FLOOR MATERIAL LEGEND NEST ELEVATION AMNOCIZED ALUMINUM STOREFRONT IF/ CLEAR Svl NSON GLAZING BY OLDCASTLE BULDNO ENKLOPECOLOR. MEDIUM BRONZE SOUTH ELEVATION___ ROUGH CUT FIELD STONE, SINLAR TO VOEELMAN 5tI NEST STONE a MASONRY, COLCR/STriC: AN LOCELMBROWN CHOPPED Seg SMOOTH FACE STONE UNITS, SMkAR TO SEE WEST AM EAST ELEVATIONS TOTAL PROPOSED ARRS(`RAFI INTERNATIONAL RENAISSANCE MASONRY UNITS COLOR: SUNSET O57 6' PREFINISHED CEMENT BOARD SUNG BY t5-4 1/4' NALGREENS SCRIPT SIN ''RYE TINU PNARVACY DIRECTIONAL SIN DON (NOT NCLU0E0 N 1OTAL) WALGREENS SCRDI 'W SCN TOTAL PROPOSED JAMESHAROE COMMERCIAL PRODUCTS COLOR/STYLEr aDARUIL LAP SUING, CHESDAJI SITE SIGNAGE BROWNI M"UEMt SXMAGE PREDNISEO STANCMC SFAM METAL NOOFNO BY TOTAL PROPOSED BERROCE MAN.UFACIIMFRO COMPANY. MORN CHARCOAL GREY Irl FILO STAINED 6' CEDAR PICX(I FENCING SIGN AREA SUMMARY NEST ELEVATION '1EXIT' DIRECTIONAL STN 001 (NOT NCUIDED IN 10TAL( TOTAL PROPOSED Ti.O Sr, DOD SF. _ SOUTH ELEVATION___ NONE PROPOSED0 IOFAL POWOSI) SF. 0,00 SF, NORTH ELEVATION SEE WEST AM EAST ELEVATIONS TOTAL PROPOSED 0.00 S.F. EAST ELEVATION t5-4 1/4' NALGREENS SCRIPT SIN ''RYE TINU PNARVACY DIRECTIONAL SIN DON (NOT NCLU0E0 N 1OTAL) WALGREENS SCRDI 'W SCN TOTAL PROPOSED 99.86 S.F. 6,0 SF. 13.1 SF, I42.96 SF. SITE SIGNAGE M"UEMt SXMAGE 30.0SF. TOTAL PROPOSED 30,0 SF. ENTRY TOWER ELEVATION WAeiREENS SCRIPT 'W SON TOTAL PROPOSED /3.1 ST. 13.10 SF. TOTAL SIGNAGE PROPOSED 216.06 S.F. TOTAL SIGNAGE ALLOWED 217.00 SF, ALLOWABLE SIGNAGE'. DIE (1) SUMARL FOOT O SIGNAGE PER ONE (1) LINEAR FOOT OF BUILONC ALOFK, tOr FRONT, LOT FAINT CONSIDERED FRONIACE ALONG AVON RD OR SUN RD _ T/MA50NRY ,_., t/NASONFtx S' (H ) 6' (W) AUFREENS -LIT IIB -D- E%O•O FgRY, BACK SKu T/MASGItY IO_O. Ik PhEFIASE0 STANDNG SEAM MC1AL ROOFING. /EFGN T LTn _ _ _ _ _ _ �+ 1 c - _ wGNI$1E5 CEMENT BOARD .. .. ' - 'j_ ue PREF r_ .111I - _ ♦ :�! . . � ( �-.FRALNO�R `:� .. _ - --___ _—RSY.Ir.H CUT sa STONE 1 CIT STONE Flo 5=0NE 1n»oaEs SOUTH ELEVATION - SUN RD SCALE: I .1 -p 05.09.11 / Dq -1-4, .1\ CR Comm. #511017 architecture + - - -. FIN16HC0 TLOCS rIALSH[D liRApC CEDAR FERM S4a'+r-MONUMENT SIGN — SCALC I/A%1"-O' (1YP. OF 2) t4�- 3 / 0 CEMENT PREFINISIED CEMENT BOARD SMOOTH FACE ALLRnxul S�TOREIROHT r/WASGIRY 132-8 es, 90116 STONE UMTS whom tss, 7/TOWER - -PREFINIISH O CEMENT BOARD 123-0' ' . _. _ - _ SUNG cs7 I/MAICINWr - 71 VIII�IIIIoI�IIF -- - _ - - - -- SMOOTH FACE 'jhtl6'_6 _ _ - _ slow LN17S slz - PREPfRSEO STANDING SEAN METAL ROOFING. rYR ALP, RO” CUT FIELD STONE T' 117-C• -HEAVY TIMBER 511 ry.e .y "(/����-��' Y FRAAING f. S. - ADORE SS ADOK DOORWAY CUT ID2'-D' ' ' I I j - iislow }�L - ROUON CIT FIELD SFC[ CUT—/ CONCEPTUAL—Z Sal rEt1ODSTONE ELECTRICAL SERFia--HEAvr nu6fR F+REFIr;l5nf0 Sfu10.NG ENTRANCE NORTH ELEVATION RAM:NGAu MLTA1 Baa: . TISCBE: 1/B =1 -O F-0* tLtvAA v1 Qk44K =- Annk►MI m' '-r T-00 Avon Rd & Sun Rd, Avon, Colorado 2 137'-0"_ T/MASONRY SMOOTH FACE STONE UNITS ST2 123'-8" _ T/MASONRY 118'-0" _ T/MASONRY 100'-0" _ FINISHED FLOOR NON-ILLUMINATED CHANNEL LETTER SET WITH EXTERNAL MOUNTED GOOSENECK LIGHTING 5T2 SMOOTH FACE STONE UNITS—\ PREFINISHED CEMENT BOARD c5D SIDING 1 12 41 SMOOTH FACE 12 ST2 STONE UNITS 2 EAST ELEVATION - AVON RD SCALE: 1/8"=f -O" PREFINISHED CEMENT BOARD SIDING csD — ROUGH CUT FIELD STONE STD r—ROUGH CUT `—DOMESTIC WATER & `—CEDAR FENCING FIELD STONE WEST ELEVATION GAS ENTRANCE ci D ST1 SCALE: 1/8"=1'-O" 1 4 architecture + d e s i g n i ROUGH CUT FIELD STONE ST, SOUTH ELEVATION - SUN RD SCALE: 1/8"=l' -O" REVISED 09.14.11 CR Comm. #511017 _ WL 4 I.� �y ' / •jj il+'SARR'giii� ALUMINUM STOREFRONT WINDOWS E 134-4" T/TOWER PREFINISHED CEMENT BOARD SIDING csD — T/MASONRY PREFINISHED STANDING SEAM METAL ROOFING, TYP MR1 —HEAVY TIMBER FRAMING ADDRESS ABOVE DOORWAY ROUGH CUT FIELD STONE ST1 102'-0" T/PLANTER 100'-0" FINISHED FLOOR 141-4" T/MASONRY NON -ILLUMINATED CHANNEL LETTER SET WITH EXTERNAL MOUNTED GOOSENECK LIGHTING PREFINISHED CEMENT BOARD SIDING csD 123'-8" T/MASONRY 118'-0" T/MASONRY S SMOOTH FACE STONE UNITS sT2 141'-4" — T/TOWER 102'- 0" T/PLANTER _ 100'-0" — FINISHED FLOOR 133-8" T/MASONRY PREFINISHED STANDING SEAM METAL ROOFING, TYP fu_pi�, HEAVY TIMBER FRAMING PREFINISHED CEMENT BOARD csD SIDING - -- 123'-8" T/MASONRY 12 14 100'-0" _ _ FINISHED FLOOR I` ROUGH COT =s s FIELD STa1�� k r� - GG NO: r ROUGH CUT CONCEPTUAL FIELD STONE ELECTRICAL SERVICE GD ENTRANCE ST2 SMOOTH FACE STONE UNITS MATERIAL LEGEND SUMMARY 12 134-4" VISION GLAZING BY OLE BUILDING 14 ENVELOPE. COLOR: MEDIUM BRONZE ROUGH CUT FIELD STONE, SIMILAR TO VOGELMAN T/TOWER - - -_- NON-ILLUMINATED- sT2 SMOOTH FACE STONE UNITS, SIMILAR TO CHANNEL LETTER SET -_ 0.00 S,F. WITH EXTERNAL csD 6" PREFINISHED CEMENT BOARD SIDING BY MOUNTED GOOSENECK — LIGHTING- SITE SIGNAGE BROWN PREFINISHED CEMENT BOARD - TOTAL PROPOSED csD SIDING -- 118'-0„ - - T/MASONRY = - - -- - - PREFINISHED STANDING SEAM METAL ROOFING, - - _ - _ -_ TYP 12 - HEAVY TIMBER - FRAMING ADDRESS ABOVE DOORWAY - - - - La 100'-0", FINISHED FLOOR ROUGH CUT ALUMINUM STOREFRONT FIELD STONE 5FD WINDOWS TD 137'-0"_ T/MASONRY SMOOTH FACE STONE UNITS ST2 123'-8" _ T/MASONRY 118'-0" _ T/MASONRY 100'-0" _ FINISHED FLOOR NON-ILLUMINATED CHANNEL LETTER SET WITH EXTERNAL MOUNTED GOOSENECK LIGHTING 5T2 SMOOTH FACE STONE UNITS—\ PREFINISHED CEMENT BOARD c5D SIDING 1 12 41 SMOOTH FACE 12 ST2 STONE UNITS 2 EAST ELEVATION - AVON RD SCALE: 1/8"=f -O" PREFINISHED CEMENT BOARD SIDING csD — ROUGH CUT FIELD STONE STD r—ROUGH CUT `—DOMESTIC WATER & `—CEDAR FENCING FIELD STONE WEST ELEVATION GAS ENTRANCE ci D ST1 SCALE: 1/8"=1'-O" 1 4 architecture + d e s i g n i ROUGH CUT FIELD STONE ST, SOUTH ELEVATION - SUN RD SCALE: 1/8"=l' -O" REVISED 09.14.11 CR Comm. #511017 _ WL 4 I.� �y ' / •jj il+'SARR'giii� ALUMINUM STOREFRONT WINDOWS E 134-4" T/TOWER PREFINISHED CEMENT BOARD SIDING csD — T/MASONRY PREFINISHED STANDING SEAM METAL ROOFING, TYP MR1 —HEAVY TIMBER FRAMING ADDRESS ABOVE DOORWAY ROUGH CUT FIELD STONE ST1 102'-0" T/PLANTER 100'-0" FINISHED FLOOR 141-4" T/MASONRY NON -ILLUMINATED CHANNEL LETTER SET WITH EXTERNAL MOUNTED GOOSENECK LIGHTING PREFINISHED CEMENT BOARD SIDING csD 123'-8" T/MASONRY 118'-0" T/MASONRY S SMOOTH FACE STONE UNITS sT2 141'-4" — T/TOWER 102'- 0" T/PLANTER _ 100'-0" — FINISHED FLOOR 133-8" T/MASONRY PREFINISHED STANDING SEAM METAL ROOFING, TYP fu_pi�, HEAVY TIMBER FRAMING PREFINISHED CEMENT BOARD csD SIDING - -- 123'-8" T/MASONRY 12 14 100'-0" _ _ FINISHED FLOOR I` ROUGH COT =s s FIELD STa1�� k r� - GG NO: r ROUGH CUT CONCEPTUAL FIELD STONE ELECTRICAL SERVICE GD ENTRANCE ST2 SMOOTH FACE STONE UNITS MATERIAL LEGEND SUMMARY ANNODIZED ALUMINUM STOREFRONT W/ CLEAR sFD VISION GLAZING BY OLE BUILDING 6.0 S.F. 0.00 S.F. ENVELOPE. COLOR: MEDIUM BRONZE ROUGH CUT FIELD STONE, SIMILAR TO VOGELMAN 5T1 WEST STONE & MASONRY, COLOR/STYLE: 0 S.F. 0.00 S.F. VOGELMAN BROWN CHOPPED sT2 SMOOTH FACE STONE UNITS, SIMILAR TO ARRISCRAFT INTERNATIONAL RENAISSANCE 0.00 S,F. MASONRY UNITS, COLOR: SUNSET csD 6" PREFINISHED CEMENT BOARD SIDING BY JAMESHARDIE COMMERCIAL PRODUCTS. COLOR/STYLE: CEDARMILL LAP SIDING, CHESTNUT SITE SIGNAGE BROWN MR1 PREFINISHED STANDING SEAM METAL ROOFING BY TOTAL PROPOSED BERRIDGE MANUFACTURING COMPANY, COLOR: CHARCOAL GREY cFD FIELD STAINED 6" CEDAR PICKET FENCING 108'-0" — T/SIGN 100'-0" _ FINISHED GRADE ALUMINUM STOREFRONT WINDOWS sFD SIGN AREA SUMMARY WEST ELEVATION *EXIT DIRECTIONAL SIGN BOX (NOT INCLUDED IN TOTAL) TOTAL PROPOSED 6.0 S.F. 0.00 S.F. SOUTH ELEVATION NONE PROPOSED TOTAL PROPOSED 0 S.F. 0.00 S.F. NORTH ELEVATION SEE WEST AND EAST ELEVATIONS TOTAL PROPOSED 0.00 S,F. EAST ELEVATION 18'-4 1/4" WALGREENS SCRIPT SIGN 99.86 S.F. ''DRIVE THRU PHARMACY DIRECTIONAL SIGN BOX (NOT INCLUDED IN TOTAL) 6.0 S.F. WALGREENS SCRIPT 'W SIGN 43.1 S.F. TOTAL PROPOSED 142.96 S.F. SITE SIGNAGE MONUMENT SIGNAGE 30.0 S.F. TOTAL PROPOSED 30,0 S.F. ENTRY TOWER ELEVATION WALGREENS SCRIPT 'W SIGN TOTAL PROPOSED 43,1 S.F, 43.10 S.F. TOTAL SIGNAGE PROPOSED 216.06 S.F. TOTAL SIGNAGE ALLOWED 217.00 S.F. ALLOWABLE SIGNAGE: ONE (1) SQUARE FOOT OF SIGNAGE PER ONE (1) LINEAR FOOT OF BUILDING ALONG LOT FRONT, LOT FRONT CONSIDERED FRONTAGE ALONG AVON RD & SUN RD 'H) x 6' (W) -ILLUMINATED CHANNEL fER SET WALGREENS UMENT SIGN W/ _RNAL 4' LINEAR LED )D LIGHT EACH SIDE MONUMENT SIGN SCALE: 1/4"=1'-0" (TYP, OF 2) "INISHED CEMENT BOARD VG CSD GH CUT 5T1 D STONE NORTH ELEVATION HEAVY TIMBER \—PREFINISHED STANDING FRAMING SEAM METAL ROOFING, TYP MRD Alternate 2m.12/4m.12 Plan - Elevations -Walgreens Avon Rd &Sun Rd, Avon, Colorado — SMOOTH FACE STONE UNITS sT2 —PREFINISHED CEMENT BOARD SIDING csD — R/CANOPY CUT TONE K� LUMINAIRE SCHEDULE Description Symbol Avg Max Min Max/Min Avg/Min Lot Summary X 4.0 fc 12.9 fc 1.5 fc 8.6:1 2.7:1 No. Lobel Symbol Lobel Qty Cotolog Number Description Lomp File Lumens LLF Wotts E3> 25.0 227.1 AS1 LED 1 ASI LED WITH HLM ONE 1 LED, 4961.9 4370.3 25.0 25.0 -90.0 A 4 63B530/40K SR3 MODULE, 63 LED's, DOWN PTT ASI -LED-1 _6 Absolute 0.69 324,9 ° m' A 5062.2 4463.1 530mA DRIVER, 4000K 25.0 3B530_40K_S 0.0 5 D B' 4434,1 12.0 12.0 COLOR TEMPERATURE, 0.0 R3.ies D 4953.9 4434,1 12.0 12.0 180.0 0.0 TYPE 3 LENS D 4969.5 4434,1 12.0 12.0 180.0 0.0 8 ASW1 LED 1 ASW1 LED WITH HLM ONE 75 -WATT LED, 12.0 12.0 180.0 0.0 B D 7 63B350/40K SR3 MODULE, 63 LED's, AIMED DOWN POS. 90.0 Absolute 0.69 75 5012.9 4477,3 12.0 12.0 350mA DRIVER, 4000K 0.0 _63W1150EDOK_ D 5012.9 4492.8 12.0 12.0 90.0 0.0 COLOR TEMPERATURE, E SR3.ies 4557,1 25.0 25.0 0.0 0.0 13 E TYPE 3 LENS 4533.3 25.0 25.0 90.0 0.0 14 E 5013.0 EM17 175M MED EUROTIQUE ONE 175 -WATT CLEAR 90.0 0.0 15 E O E 5 GCF SR2 ARCHITECTURAL ED17 METAL HALIDE, EM17_175M_ 12800 0.72 213.5 25.0 25.0 0.0 0.0 LUMINAIRE WITH SR2 HORIZONTAL POS. MED_GCF_SR 4487,0 25.0 25.0 0.0 0.0 18 F REFLECTOR, CLEAR 4581,8 2.ies 25.0 63.1 0.0 19 C 5067,5 4438.0 FLAT GLASS LENS. 3.0 0.0 0.0 20 C 5069.4 4430.5 3.0 3100 LED WHT53K 8-27/32 DIA. X 22"H. 0.0 21 C 5085.5 4434.5 3.0 C 7 MVOLT SYM BOLLARD LUMINAIRE 16 60.3 WATT LED ARRAY 3100 -LED -WH Absolute 0.69 61,15 0.0 0.0 23 C COOL WHITE LEDS, 4440.6 T53K_MVOLT_ 3.0 0.0 0.0 24 C 5071.7 4439.0 FROSTED LENS BLACK 3.0 SYM.ies 0.0 25 C 5073.9 4432.1 3.0 3.0 PAINTED REFLECTOR 0.0 26 F 5027.3 4579.1 25.0 25.0 134,3 AS1 LED 1 ASI LED WITH Ls, ONE 108.3 -WATT LED, ` El F 3 63B530/40K SR3 MODULE,, 63 LED AIMED DOWN POS, ASI _LED_1_6 Absolute 0.69 216.6 c b.0 6 1.5 530mA DRIVER, 4000K 0. 3B530_40K_S El COLOR TEMPERATURE, R3.ies .5 '1.8 '1.2 b.8 b.4 TYPE 3 LENS b. b.1 b.1 b.0 LUMINAIRE LOCATIONS Description Symbol Avg Max Min Max/Min Avg/Min Lot Summary X 4.0 fc 12.9 fc 1.5 fc 8.6:1 2.7:1 No. Lobel X Locotion Y Z MH Orientotion Tilt 1 A 5054.0 4391,8 25.0 25.0 227.1 0.0 2 A 4961.9 4370.3 25.0 25.0 -90.0 0.0 3 A 4868.3 4404,4 25.0 25.0 -21,8 0.0 4 A 5062.2 4463.1 25.0 25.0 167.6 0.0 5 D 4938.5 4434,1 12.0 12.0 180.0 0.0 6 D 4953.9 4434,1 12.0 12.0 180.0 0.0 7 D 4969.5 4434,1 12.0 12.0 180.0 0.0 8 D 4985.0 4434,1 12.0 12.0 180.0 0.0 9 D 5012.9 4461.8 12.0 12.0 90.0 0.0 10 D 5012.9 4477,3 12.0 12.0 90.0 0.0 11 D 5012.9 4492.8 12.0 12.0 90.0 0.0 12 E 4988.0 4557,1 25.0 25.0 0.0 0.0 13 E 5013.0 4533.3 25.0 25.0 90.0 0.0 14 E 5013.0 4523.9 25.0 25.0 90.0 0.0 15 E 4978.7 4557.1 25.0 25.0 0.0 0.0 16 E 4969.4 4557.1 25.0 25.0 0.0 0.0 17 F 4881,8 4487,0 25.0 25.0 0.0 0.0 18 F 4915.6 4581,8 25.0 25.0 63.1 0.0 19 C 5067,5 4438.0 3.0 3.0 0.0 0.0 20 C 5069.4 4430.5 3.0 3.0 0.0 0.0 21 C 5085.5 4434.5 3.0 3.0 0.0 0.0 22 C 5078.4 4434.3 3.0 3.0 0.0 0.0 23 C 5075.5 4440.6 3.0 3.0 0.0 0.0 24 C 5071.7 4439.0 3.0 3.0 0.0 0.0 25 C 5073.9 4432.1 3.0 3.0 0.0 0.0 26 F 5027.3 4579.1 25.0 25.0 134,3 0.0 STATIS11CS b.4 Description Symbol Avg Max Min Max/Min Avg/Min Lot Summary X 4.0 fc 12.9 fc 1.5 fc 8.6:1 2.7:1 Spill Light Summary + 1.4 fc 12.9 fc 0.0 fc N / A N / A NOTES 1. Refer to luminaire schedule for total LLF. 2. Please refer to the "luminoire locations" table for mounting heights. 3. Product information con be obtained at www.Lithonio.com or through your local agency. 4. Due to project requirements for LED products we ore unable to comply to current Wolgreens criteria. b.0 b.0 b.0 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.2 b.2 b.1 b.1 b.1 b.0 b.0 b.0 b.0 b.0 b.0 b.1 b.1 b.1 b.1 b.2 b.2 b.2 b.1 b.1 b.1 b.1 b.1 b.2 b.2 b.3 b.3 b.3 b.2 b.1 b.1 b.0 b.0 b.0 b.0 b.0 b.1 b.1 b.1 b.2 b.3 b.4 b.4 b.3 b.3 b.2 b.2 b.3 b.4 b.5 b.4 b.6 b.6 b.5 b.3 b.2 b.1 b.1 b.0 b.0 b.0 b.0 b.0 b.1 b.1 b.2 b.3 b.4 b.6 b.8 b.7 b.6 b.6 b.7 b.6 b.6 b.9 '1.2 '1.2 '1.0 '1.1 '1.0 b.5 b.3 b.2 b.1 b.1 b.0 b.0 b.0 b.1 b.1 b.2 b.3 b.6 b.8 b.9 '1.1 '1.4 '1.7 '1.8 '1.6 '1.3 '1.5 '1.8 2.1 2.4 2.3 '1.5 '1.3 b.9 b.5 b.3 b.2 b.1 b.1 b.0 b.0 S = MON�� = ININI� b.0 b.0 b.1 b.1 b.2 b.4 b.7 '1.0 '1.8 2.5 2.7 2.7 2.7 2.4 2.2 2.3 2.7 3.1 3.5 3.5 3.0 7 '1 '1.0 b.5 b.3 b.2 b.1 b.0 b.0 o b.0 b.0 b.1 b.1 b.2 b.5 '1.1 3.0 0 3.9 3.8 3.4 3.�3'3 4 3.2 3.2 3.5 3.8 4.2 5.1 �.$� 3.21 '1.8 '1.2 b.7 b.4 b.2 b.1 b.1 b.0 b.0 b.0 b.1 b.1 b.3 b.9 '1.7 ,2.4 b.0 b.0 b.1 b.1 10.4 1.0 *1.7/ 1.7 2.4 b.0 b.0 b.1 b.1 b.1 b.2 b.7 '16 .7 b.0 b.0 b.1 b.1 b.1 b.2 b.7 '1.3 `1.6 b.0 b.0 b.1 b.1 b.1 b.2 b.3 b.9 , '1.5 `1.7 b.0 b.0 b.1 b.1 b.2 b.3 b.5 .8 2.0 b.0 b.0 b.1 b.1 b.3 b.5 b.6 , '1.7 2.1 2.1 b.0 b.0 b.1 b.1 b.3 b.7 b.9 2.0 2.7 2.5 b.0 b.0 b.1 b.2 b.3 b.6 '1. 2.4 e 'F2 --2.8 13 F-17 a lI b.0 b.1 b.1 b.2 b.3 b.7 '1.0 2.2 .0 12.7 III b.0 b.1 b.1 b.2 b.4 b.7 b.9 2.2 b.1 b.1 b.1 b.2 b.5 '1.3 �.7 2.4 I b.1 b.1 b.1 b.3 b.8 '1.4 '1.9 2. �-.9 -2.6 b.1 b.1 b.2 b.3 b.9 2.1 2.7 3.0 33 2.X b.1 b.2 b.3 b.5 2.4 3.2 3.3 3.4 2.7 b.1 b.2 b.4 b.7 2.7 .7 4.0 3\ 3.0 b.1 b.2 b.4 b.9 '1.3 0# '2.3 �. 4 3.8 `3 o A-3 b.1 b.1 b.3 b.7 '1.0 '1.6 3. 4.4 3.7 3.3 b.1 b.1 b.2 b.4 b.9 '1.3 ##4 3.2 3.3 2.9 b.1 b.2 b.3 b.8 b.9 *1.3\ 2.6----- 2.5 b.1 b.1 b.2 b.4 b.5 b.6 '10# '1.7 b.1 b.1 b.2 b.3 b.3 b.5 b.9 b.1 b.1 b.2 b.1 b.2 b.2 .2 b.7 b.4 b.2 b.1 b.1 b.0 O .6 b.7 b.4 b.2 b.1 b.1 b.0 O QWO .5 b.7 b.3 b.1 b.1 b.1 b.0 Q z0� .0 b.5 b.2 b.1 b.1 b.1 b.0 b.0 Zrt) .4 b.2 b.1 b.1 b.1 b.0 b.0 a b.4 b.2 b.2 b.1 b.1 b.0 b.0 b.0 b.5 b.3 b.3 b.2 b.1 b.1 b.0 b.0 .0 b.8 b.6 b.4 b.2 b.1 b.1 b.0 b.0 b.0 .8 '1 5 9 b.8 b.3 b.2 b.1 b.0 b.0 b.0 .5 11. '1.0 b.4 b.2 b.1 b.1 b.0 b.0 U O O 6 3.2 '1.5 b.9 b.5 b.2 b.1 b.1 b.0 b.0 Q Q N .2 3.8 '1.7 '1.2 b.6 b.3 b.1 b.1 b.0 b.0 � U � 3 4.8 3. 11. b.8 b.3 b.1 b.1 b.0 b.0 3 > a O o Z vi o .6 8 1.6 4.6 b.8 b.3 b.2 b.1 b.0 b.0 0 U ~ Q Y v .6 '$. 9.4 3. b. 3 b.2 b.1 b.1 b.0 .f-2 5/2`2/21 3 G Z ccoo m U .8 4.6 3.2 `1.5 5 b.2 b.1 b.1 b.1 b.0 .7 3.6 2.5 b.8 b.3 b.2 b.1 b.1 b.1 b.0 ` 3.0 b.6 b.2 b.1 b.1 b.1 b.0 6 1.5 0. .5 '1.8 '1.2 b.8 b.4 ♦ b. b.1 b.1 b.0 .7 '1.2 '1.0 b.6 b.3 ,,A.2 b.1 1 b.0 b.0 .2, U,@ --b b.3 .2 1001 b.1 b.0 b.0 b.0 .8 b.6 b.3 b.2 _ b.1 b.0 b.0 b.0 UL -i L -1- b.2 b.4 '0.7 '1.1 '1.1 '1.1 '1.1 b.7 '0.4 '0.3 '0.3 b.3 b.3 b.4 b.4 b.3 b.2 b.1 b.1 b.0 b.0 b.0 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.2 b.3 b.5 b.7 b.6 b.7 b.7 '0.5 b.3 b.2 b.2 b.2 b.2 b.2 b.2 b.1 b.1 b.1 b.0 b.0 b.0 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.2 b.2 b.3 b.3 '0.3 b.3 b.2 b.2 b.2 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.0 b.0 b.0 b.0 b.0 b.0 b.0 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.1 b.0 b.0 b.0 b.0 b.0 b.0 b.0 b.0 b.0 b.1 '0.1 b.1 '0.1 b.1 b.1 b.1 b.1 b.1 '0.1 b.1 b.1 b.1 b.0 b.0 b.0 b.0 b.0 b.0 b.0 b.0 b.o b.o b.0 b.0 b.0 b.o b.0 b.0 b.0 b.0 b.o b.0 b.0 b.0 b.0 b.0 SITE PHOTOMETRICS PLAN "y,�� SCALE: 1"=20'-0" ti LITHONIA LIGHTING Designer Jim Eads, LC Date August 31, 2011 Scale As Shown Drawing No. 80009311 A3 /PRELIMINARY NOT FOR CONSTRUCTION This document is partially complete. The information contained is not necessarily coordinated or correct. This drawing is for review purposes only. i I z + � ~ �c/5w ?o0�woz ~ � � W ~ U- 07 J W LL UuZZ) I_ol- �XoW=oZW I- WUZi-- C) g°zovi�oazo�o� UZI=o=LL°UQ i-- Lu Ci °Z) =°E z w�a JC/, c/)000U0> =oWo_co �aaQoLL ?3oaaw� rn z O U) LU o' O a Lz(o w z ° O cD W LU Z LL O 00 i 00 C/) 0::) v J � OU O M '1' W LU C-6 z O O QWO N Q O N J °� LL Q z0� Q) (D U) _ M J Zrt) V) o a a CD N � � o W N M a _ > O a Y N O 0 CO c U p co O U O O N N Q Q N N co � U � � Y E N N 6 '2 3 > a O o Z vi o O rn N Cfl 0 U ~ Q Y v Q Z Lu co v V' a> Z U > z Z 3 G Z ccoo m U Q) N U U /PRELIMINARY NOT FOR CONSTRUCTION This document is partially complete. The information contained is not necessarily coordinated or correct. This drawing is for review purposes only. i I z + � ~ �c/5w ?o0�woz ~ � � W ~ U- 07 J W LL UuZZ) I_ol- �XoW=oZW I- WUZi-- C) g°zovi�oazo�o� UZI=o=LL°UQ i-- Lu Ci °Z) =°E z w�a JC/, c/)000U0> =oWo_co �aaQoLL ?3oaaw� rn z O U) LU o' O a Lz(o w z ° O cD W LU Z LL 0 L0 0 z O U U 7 Z 4FF r 0 L6 0 En 0 Lu LU W On H tY C/) 0::) v J � OU 0 0 '1' W LU C-6 z OCD � OC'5 QWO ZQ LL O O Q W J °� LL Q z0� Q) I' U) _ O J 0 L0 0 z O U U 7 Z 4FF r 0 L6 0 En 0 Lu LU W On EXISTING CRAB- APPLE TREE TO REMAIN (TYP.) + 3 1 PPG PROPERTY L 2X BALL DIA. NOTES: MIN. 1. DECIDUOUS TREES TO BE PLANTED AT OR SLIGHTLY ABOVE FINISH GRADE. 2. WATER THOROUGHLY AT THE TIME OF PLANTING. DO NOT FERTILIZE AT THE TIME OF PLANTING. DO NOT PRUNE OR DAMAGE LEADER NYLON WEBBING STRAP BITUMINOUS IMPREGNATED TREE WRAP -FASTEN TOP $ BOTTOM (FALL INSTAL- LATION ONLY) 6' LONG METAL "T" POST PAINTED GREEN MULCH SAUCER RIM (SEE NOTES) FINISH GRADE EXISTING UNDISTURBED SUBGRADE REMOVE TOP 1/5 OF BURLAP $ ALL WIRE/METAL, ETC. BACKFILL AS SPECIFIED COMPACTED SPECIFIED BACKFILL FOR SETTING OF ROOTBALL THIS AREA HAS RCC�I OCiIQCr1 SUN ROAD J 2X BALL DIA. NOTES: MIN. OUTCROPPING COBBLE ON FILTER FABRIC (TYPJ PERENNIAL FLOWER5 AND GROUNDCOVER (TYPJ -PROPOSED MONUMENT SIGN -7� 02 �O �Q 3 PTA 1 VLM 6 SJF 3 SSU EXISTING COTTONWOOD TREE TO BE REMOVED //--I VLM EXISTING SCULPTURES 4 MSG I PPG EXISTING SPRUCE TREE TO BE REMOVED (TYPJ NOTE: EXISTING LARGE RIVER ROCK BOULDER AT CORNER OF AVON ROAD AND SUN ROAD TO BE REMOVED FROM SITE. DO NOT PRUNE OR DAMAGE LEADER. ANY PRUNING MUST F I RST BE APPROVED BY LANDSCAPE ARCHITECT 3 GUY WIRES AT 120 DEGREES O.G., USE NYLON WEBBING STRAP AT TREE FLAGGING 3-18" LONG METAL STAKES SET PERPENDICULAR TO WIRE AND FLUSH WITH FINISH GRADE SAUCER RIM FINISH GRADE EXISTING UNDISTURBED SUBGRADE REMOVE TOP 1/3 OF BURLAP 4 ALL AIRE/METAL, ETC. BACKFILL AS SPECIFIED COMPACTED SPECIFIED BACKFILL FOR SETTING OF ROOTBALL 3. SAUCER RIM IS TO BE ON DOWNHILL I. EVERGREEN TREES TO BE 3. SAUCER RIM IS TO BE ON DOWNHILL SIDE WHEN PLANTS ARE PLANTED PLANTED 5" ABOVE SIDE WHEN PLANTS ARE PLANTED ON SLOPES, BUT SHALL SURROUND FINISH GRADE. ON SLOPES, BUT SHALL SURROUND PLANT WHEN ON LEVEL GROUND. PLANT WHEN ON LEVEL GROUND. 2. WATER THOROUGHLY AT THE TIME OF PLANTING. DO NOT FERTILIZE AT THE TIME OF PLANTING. 0 IDCI[DL�OL�5 TREE PLANTING EVERGREEN TREE PL,4NTIN NOT TO SCALE (D NOT TO SCALE 2 55U 5 HSB STONE VENEER SEAT WALL SEAT HT. BOULDER "SLAB° PAVER "PLAZA" PLANT JC�4 DUL.E QTY. SYMBOL COMMON NAME BOTANIC NAME SIZE NOTES DECIDUOUS TREES 3 PAR RUSSIAN SAGE 7 GSC 0f PTA QUAKING ASPEN POPULUS TREMULOIDES 2"-3" CALIPER 1/2 MULTI -STEM 4 FPP PATMORE ASH FRAXINUS PENNSYLVANICA 'PATMORE' 3" GALIPER MATCHED SET 4 MRB RED BARRON CRABAPPLE MALUS 'RED BARRON' 2'' CALIPER MATCHED SET EVERGREEN TREES 10 MSG GRAZ I ELLA MAIDEN GRASS 6 PPS COLORADO SPRUCE PIGEA PUNGENS I0'-I4'5$E3 SEE PLAN FOR DECIDUOUS/ EVERGREEN SHRUBS 5 CLP PEKING COTONEASTER 6 VLM WAYFARING TREE 3 PAR RUSSIAN SAGE 7 GSC BAILEY REDTWIG DOGWOOD 12 SAW SILVER CREEPING WILLOW 3 SPN DWARF ARCTIC WILLOW 10 SJF FROEBEL SPIREA 6 57F FAIRY QUEEN SPIREA 30 SSU URAL FALSE SPIREA 10 MSG GRAZ I ELLA MAIDEN GRASS 52 HSB BLUE AVENA GRASS 23 PPG DWARF GLOBE BLUE SPRUCE 3 PPV MESA VERDE SPRUCE I PMM SLOAMOUND MUCO PINE GENERAL NOTE6 COTONEASTER LUGII )US VIBURNUM LANTANA PEROVSKIA ATRIPLICIFOLIA CORNUS STOLONIFERA 'BAILEYI' SAL I X ARENAR I A SALIX PURPUREA NANA SPIRAEA JAPONICA 'FROEBELLI' SPIRAEA TRILOBATA 'FAIRY QUEEN' SORBARIA SORBIFOLIA MISCANTHUS SINENSIS 'GRAZIELLA' HEL I GTOTRI LHON SEMPERV I RENS PIGEA PUNGENS 'GLOBOSA' PIGEA PUNGENS 'MESA VERDE' PINUS MUCO 'SLOAMOUND' 5 GAL. CONT. 7 GAL. CONT. 5 GAL. CONT. 7 GAL. CONT. 5 GAL. CONT. 5 GAL. CONT. 5 GAL. CONT. 5 GAL. CONT. 5 GAL. CONT. 5 GAL. CONT. I GAL. CONT. 6 GAL. CONT. 6 GAL. CONT. 6 GAL. CONT. LOCATIONS OF 14' TREES 1. LANDSCAPE CONTRACTOR SHALL SUBM 1 T A WRITTEN DOCUMENT REGARDING ITS POLICY ON PLANT GUARANTEE AND REPLACEMENT TO THE OWNER. EACH GUARANTEE SHALL CONFORM TO THE MINIMUM STANDARD OF REPLACING ALL MATERIAL INCLUDING LABOR, DUE TO SICKNESS, DEATH, OR UNSATISFACTORY CONDITION OF A PLANT FOR A PERIOD OF ONE YEAR FOLLOWING INSTALLATION. 2. CONTRACTOR TO HAVE HAVE UTILITIES LOCATED AND STAKED AT LEAST 45 HOURS PRIOR TO BEGINNING CONSTRUCTION. 3. FURNISH AND INSTALL PLANT MATERIAL AS NOTED. ALL PLANT MATERIAL SHALL BE APPROVED BY LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. SHOULD A DISCREPANCY IN QUANTITIES OCCUR, PLANT QUANTITIES ON PLAN SHALL TAKE PRECEDENCE OVER THOSE IN THE PLANT SCHEDULE. 4. PROVIDE A STAKED LAYOUT OF ALL PLANTING LOCATIONS FOR REVIEW BY LANDSCAPE ARCHITECT PRIOR TO BEGINNING WORK. 5. PLANTING BEDS SHALL BE MULCHED W/ 3" (DEPTH) SHREDDED CEDAR MULCH. PERENNIAL FLOWER AREAS TO BE MULCHED W/ I" (DEPTH) SOIL PEP. 6. GOBBLE MULCH AREAS, WHERE SHOWN, SHALL BE 4"-6" RIVER ROCK GOBBLE ON WEED BARRIER FABRIC. 7. LANDSCAPE CONTRACTOR SHALL AMEND PLANTING BED5 AND LAWN AREAS WITH 4 CU. YARDS EKO COMPOST PER 1000 5F. S. PLANTING BACKFILL MIX SHALL CONSIST OF 805yo NATIVE TOPSOIL, AND 20% EKO COMPOST. 0i. ALL LANDSCAPING SHALL BE IRRIGATED BY MEANS OF AN AUTOMATIC UNDERGROUND IRRIGATION SYSTEM. TREES, SHRUBS, AND ORNAMENTAL GRA55ES SHALL BE DRIP IRRIGATED. 7URF6RA55, PERENNIAL FLOWERS AND GROUNDCOVER, SHALL BE IRRIGATED WITH POP-UP 5PRAY HEADS. 10. ALL BOULDERS SHOWN ON PLAN SHALL BE COMPATIBLE AI TH STONE VENEER USED ON BUILDING AND RANGE IN SIZE FROM 4'-6' LENGTH BY 2'-4' WIDTH. SPECIFIC BOULDER TYPE T.B.D. LANDSCAPE ARCHITECT TO APPROVE ALL BOULDERS AND SUPERVISE ALL BOULDER PLACEMENT. II. STEEL EDGING, WHERE SHOWN, SHALL BE RYERSON OR PRO -STEEL, 4" WITH ROLLED EDGE. 2X BALL DIA. MIN. k 5I4RL�5 PLANTIN NOT TO SG,4LE 5" MULCH PLANT ROOTBALL GRADE WHICH SHRUB GREW IN NURSERY SAUCER RIM FINISH GRADE SUBGRADE ROOTBALL (REMOVE CONTAINER) BACKFILL MATERIAL UNDISTURBED SOIL ON BOTTOM OF ROOTBALL GRAPHIC LEGEND (EXIFING) SYMBOL DESGRIFTION ma.cDesign 1 LANDSCAPE 1 ARCHITECTURE IM 9W SITE PLANNING P.O. BOX 6446, AVON, CO 81620 970.513.9345 ISSUE: 8/4/2010 PRE. -APP. GHEGK 5ET 8/6/2010 SKETCH PLAN 5UBMITTAL 4/18/2011 EX I STING SPRUCE TREE TO REMAIN 5/0i/2011 FINAL DESIGN 0{/1/2011 REVISION 0i/8/2011 REVISION 0V12/2011 REVISION • J EXISTING ASPEN TREE TO REMAIN \ + EX I STING ORNAMENTAL TREE TO REMAIN SPRUCE TREE TO BE RELOCATED (QTY. 3) RELOCATED SPRUCE TREE (OTY. 3) 0 ASPEN TREE TO BE REMOVED (OR OTHER SPECIES WHERE I ND I GATED) SPRUCE TREE TO BE REMOVED ma.cDesign 1 LANDSCAPE 1 ARCHITECTURE IM 9W SITE PLANNING P.O. BOX 6446, AVON, CO 81620 970.513.9345 ISSUE: 8/4/2010 PRE. -APP. GHEGK 5ET 8/6/2010 SKETCH PLAN 5UBMITTAL 4/18/2011 FINAL DESIGN GHEGK SET 5/0i/2011 FINAL DESIGN 0{/1/2011 REVISION 0i/8/2011 REVISION 0V12/2011 REVISION O 20 (r Scale 1'' = 20'-0" North LANDS((AFE PLAN Staff Report — Major Design and Development Plan/AEC P October 4, 2011 Planning & Zoning Commission Meeting AHN Report date September 30, 2011 Project type New Residential Construction — 4 Single Family Residences Legal description Lot 9, Block 5, Wildridge Subdivision Zoning Planned Unit Development (PUD) — 8 Units Address 1015 W Wildwood Road Prepared By Jared Barnes, Planner Ig Summary of Requests The Applicant, Michael Pukas, representing WildAvon Enterprises LLC (the Owner), has submitted a Major Design and Development application, and an Alternative Equivalent Compliance (AEC) application for four (4) new single-family residences on Lot 9, Block 5 of the Wildridge Subdivision, also described as 1015 W Wildwood Road (the Property). The Applicant is proposing to develop Phase II of the Wildstar Development, which includes four (4) single-family residences with vehicle access from a shared private driveway. The Planning and Zoning Commission (PZC) approved Phase I of the Wildstar Development, which consisted of three (3) single-family units in March of 2010. A future Phase III is shown on the development plans for the eighth single-family home. The Applicant is also proposing an AEC application for building separation, required landscaping units and bicycle parking. Staff is recommending approval of the Major Design and Development Plan, as well as the Alternative Equivalent Compliance application with the following conditions: 1. Final approval of the proposed water service line configuration is required from Eagle River Water and Sanitation District (ERWSD) prior to building permit submittal; 2. All retaining walls over four (4) feet shall be designed and certified by a Colorado licensed professional engineer; and, 3. Approval of Phase II does not constitute approval of Phase III (Unit 4). Review Criteria §7.16.080(f), Development Plan (1) Evidence of substantial compliance with the purpose of the Development Code as specified in §7.04.030, Purposes; (2) Evidence of substantial compliance with the §7.16.090, Design Review. (3) Consistency with the Avon Comprehensive Plan; (4) Consistency with any previously approved and not revoked subdivision plat, planned development, or any other precedent plan or land use approval for the property as applicable; (5) Compliance with all applicable development and design standards set forth in this Code, including but not limited to the provisions in Chapter 7.20, Zone Districts and Official Zoning Map, Chapter 7.24, Use Regulations, and Chapter 7.28, Development Standards; and (6) That the development can be adequately served by city services including but not limited to roads, water, wastewater, fire protection, and emergency medical services. §7.16.090(f), Design Review (1) The design relates the development to the character of the surrounding community; or, where redevelopment is anticipated, relates the development to the character of Avon as a whole; October 4, 2011 PZC Meeting (2) The design meets the development and design standards established in this Development Code; and (3) The design reflects the long range goals and design criteria from the Avon Comprehensive Plan and other applicable, adopted plan documents. §7.16.120, Alternative Equivalent Compliance (1) The proposed alternative achieves the intent of the subject design or development standard to the same or better degree than the subject standard; (2) The proposed alternative achieves the goals and policies of the Avon Comprehensive Plan to the same or better degree than the subject standard; (3) The proposed alternative results in benefits to the community that are equivalent to or better than compliance with the subject standard; and (4) The proposed alternative imposes no greater impacts on adjacent properties than would occur through compliance with the specific requirements of this ordinance. Property Description The Property is 1.539 acres with frontage on W. Wildwood Road on both the eastern and western property lines. The Property slopes uphill from west to east with the steepest portions of the lot adjacent to both property lines and public ROWs. In addition to typical setbacks and easements, development is restricted by a Roadway Cut and Fill Slope Easement that runs parallel to the property lines on the east and west sides of Lot 9, Block 5, Wildridge. The surrounding uses are all multi -family structures, with the exception of the Eagle River Water and Sanitation District (ERWSD) property to the east of the property along W. Wildwood Road. The shared driveway and the three (3) single-family structures in Phase 1 are under construction. Policy Analysis The Comprehensive Plan includes two planning principals for District 24: Wildridge Residential District which are relevant to this application: a. Special care should be taken to ensure that all structures are compatible with one another and in harmony with the natural surroundings; and, b. Site buildings of varying size along the street to maximize sun exposure, protect views, be compatible with existing surrounding development, and break up building bulk. The previous approval and current proposal satisfies the intent of these sections of the Comprehensive Plan. Specifically, the applicant has responded to the concerns of the Staff and PZC by separating the proposed residences for solar access and views. The applicant has also provided more architectural consistency through the use of building materials, which helps create a more compatible design within the subdivision. Planning Analysis Allowed Use and Density: The proposal for four (4) single-family residences, in addition to the previously approved three (3) single-family residences, complies with zoning which permits eight (8) residential units on the Property. Lot Coverage, Setback and Easements: Building site coverage is nineteen percent (19%) and the buildings are all located within the required setbacks. The Roadway Cut and Fill Slope Easement is for the Town's benefit for the purpose of maintaining W Wildwood Road, and all development activity is prohibited in that easement. October 4, 2011 PZC Meeting Building Height: The maximum building height permitted is thirty-five feet (35').The proposed buildings heights are as follows: Unit 5 — twenty-five feet and ten inches (25'-10"); Unit 6 — thirty feet (30'); Unit 7 — twenty eight feet and nine inches (28'-9"); Unit 8 — thirty-two feet and one inch (32'-1"). Parking: Each unit is required to provide a minimum of three (3) parking spaces. The applicant is proposing four (4) spaces per unit (two (2) in each garage and two (2) outside each garage). The project also requires four (4) guest parking spaces to be accessed off the private driveway. The applicant is proposing four (4) guest parking spaces across the drive from Units 2 and 3 to comply with this regulation. §7.28.040(e)(5), Bicycle and Pedestrian Path Connectivity, requires all projects with twenty-five (25) or more parking spaces to provide adequate bicycle parking facilities on-site. With a total of thirty-two (32) parking spaces provided, this project results in the need for four (4) on-site bicycle parking spaces. The Applicant has proposed an AEC application to be exempted from this regulation, (Attachment D). The Applicant argues that the requirements are intended for multi- family and commercial projects where bicycles can't be stored or parked in individual units. In this case, adequate bicycle parking facilities, for residents and guests, are provided in each unit garage or adjacent to the unit. Outdoor Lighting: A single full cut-off wall sconce fixture is being proposed for Phase II, (Attachment B). The proposed fixture utilizes a forty (40) watt bulb and complies with the outdoor lighting requirements. Seven (7) fixtures are proposed for each unit; located on the lower and main levels of each building and adjacent to doors or garages. Engineering Analysis Driveways: The proposed driveway configuration, grading and drainage all meet the Town's minimum standards. Due to the proximity of the water service lines to the foundations of Units 5 and 6, approval from the ERWSD is required prior to issuance of a building permit for any portion of Phase II. Retaining Walls: A series of boulder retaining walls run along the west side of the proposed drive as well as between each unit and to the south of Unit 5. The retaining walls vary in height from two (2) feet to six and one-half (6.5) feet. All retaining walls over four (4) feet must be structurally engineered, prior to the issuance of a building permit. Subdivision Requirements: The project is being developed as a common -interest (condominium) community; with each home or unit being subdivided as condominium unit surrounded by common element open space and access from a private driveway. A condominium plat will be prepared for administrative approval after the foundations for each unit are completed. Design Standards Analysis Landscaping: The development is required to provide a minimum of twenty-five percent (25%) of the Lot in landscaped area. The project contains two (2) separate landscaped areas: a 21,832 square feet Landscaped Area which is proposed around the residences and driveway; and, the 17,055 square foot Roadway Cut and Fill Slope Easement. The proposed Landscaped Area results in thirty-three percent (33%)of the total lot, but when combined with the Roadway Cut and Fill Slope Easement, the two areas provide 38,887 square feet of landscaped area or fifty-eight percent (58%) of the total lot. October 4, 2011 PZC Meeting 3 The applicant has submitted an AEC application to reduce the required landscaping requirements for the project. §7.28.050(e), Landscaping Units, requires that a minimum of one (1) landscape unit be provided per fifty (50) square feet of Landscaped Area. As exhibited in Attachment D, the applicant is requesting that the area located within the Roadway Cut and Fill Slope Easement be removed from the calculations because it is a non -developable area of the property. If this easement area is included in the unit calculation, the project would need to include 778 landscaping units, but would not be able to plant those units within the easement area. If the easement area was removed from the calculations, the project would only be required to provide 437 landscaping units If the AEC application is approve, the reduced landscaping will still result in a sufficient amount of landscaped area to meet zoning requirements. The applicant is also proposing 369 landscaping units as trees, which is eighty-two percent (82%) of the proposed landscaping units. The applicant is proposing to irrigate 4,277 square feet with spray and drip irrigation which is less than the maximum of twenty percent (20%) irrigation area, as allowed by zoning. Site Design: The proposed development has been designed with the four (4) single-family homes accessed from a private court drive. The separation between the buildings is fourteen (14) feet, which does not comply with the Development Code's minimum fifteen (15) foot separation requirement. The applicant has submitted an AEC application (Attachment D) to reduce the separation to fourteen (14) feet, which is consistent with the building separation between Units 1-3 of Phase I. Building Materials and Colors: The primary building material for all four (4) units is stucco. The proposed stucco colors are: "Sandia" (STO 1616), "San Juan" (STO 2088), and "Suede" (STO 01006). Wood siding has also been incorporated into the elevations, with a Porter Stains "Dark Oak" (#725) color. Other building materials include wood fascia trim, stucco belly bands, asphalt shingles ("Hickory" color), wood decking, and aluminum clad windows and doors ("Brown" color). A photograph of the color/material board is provided as Attachment C. The full size board will be available for review at the meeting. Roofs: All roof pitches are either six -in -twelve (6:12) or four -in -twelve (4:12) and comply with the Design Standards. All overhangs are a minimum of one and one-half (1.5) feet which also complies with the Design Standards. Staff Recommendation Staff recommends approval of the Major Design and Development Plan and the Alternative Equivalent Compliance applications, for Lot 9, Block 5, Wildridge Subdivision, Phase II, with the following conditions: 1. Final approval of a water service line configuration for Phase II is required from Eagle River Water and Sanitation District (ERWSD) prior to building permit submittal; 2. Retaining walls over four (4) feet in height shall be designed and certified by a Colorado licensed professional engineer prior to building permit submittal; and, 3. Approval of Phase II does not constitute approval for Phase III (Unit 4). Exhibits A: Vicinity Map B: Light Fixture Cut Sheet C: Color and Material Board D: AEC Materials E: Reduced Plan Sets October 4, 2011 PZC Meeting 4 0 625 125 Attachment A Vicinity Map - Lot 9, Block 5, WR — Residential Streets Property Boundaries Ruo,„ Product Detail for 49059OZ KICHLER LIGHTING �\ Available Finishes: Brushed Nickel, Olde Bronze Technical Information Type Style Finish Group Weight Body Height Width Extension Height from Junction Box Outdoor Lights Lodge / Country Bronze 0.5 LBS 7.5 IN 8 IN 9.25 IN 2.5 IN Attachment B Ripley - Outdoor Wall 1Lt 49059OZ Outdoor Wall 1 Lt Dia./Width: 8.0 IN Body Height: 7.5 IN Bringing clean lines to a rustic look, the Ripley collection of outdoor lighting features an Olde Bronze finish that warms the smooth cone shape of this 1 light outdoor sconce. 8 inch width. Height 7.5 inches. Extension 9.5 inches. Rises 2.75 inches above the center of the wall opening. Uses 1 - 40W max (type R) or 1 - 60W (G type) bulb. UL listed for wet Locations. Dark sky compliant with use of R14 4OW bulb. Backplate Dimensions Bulb Included Primary Bulb Count Primary Max Watt Primary Lamp Type Voltage UL CSA Listed Body Material 5.125 DIA IN N 1 60W A15 120 Y ALUMINUM http://www.kichler.com/products/printDetail.do?prod_id=49059&order_id... 8/31/2011 spy;. s. Attachment C 0 m Alternative Equivalent Compliance August 29, 2011 Amended -September 28, 2011 Town of Avon Community Development PO Box 975 Avon, CO 81620 Attention: Matt Pielsficker Tel: (970) 748-4413 Fax: (970) 748-5749 mpielsticker@avon.org Regarding: Alternative Equivalent Compliance Application Wildstar Residences by Dantas Builders Phase 2 - Buildings 5, 6, 7, & 8 Attachment 0 mop design shop PO Box 288 095 Willowstone Place Gypsum, CO 81637 c 970-390-4931 michael@mpadesianshoa.com We are submitting an Alternative Equivalent Compliance Application along w/ the Major Development Application for the following items; 1. Building spacing to be 14' minimum at foundations a. For building 1, 2 and 3 of Phase 1 the building are spaced at 14' to the foundations. These building were designed and approved prior to the changes to the Town's Development Code. 2. Landscaping Units a. The Site and Landscape Plans and Landscape Unit Calculations being submitted under this application are for all 8 Buildings of Phases 1 and 2. b. Lot 9 has a Slope Maintenance, Drainage, and Snow Storage Easement that cannot be developed in anyway. c. We are excluding this area from the Landscaping Unit calculations. i. Total Lot Area - 67,047 sq ft / 1.5392 Acres ii. Required Landscape area Q 25%- 16,762 sq ft iii. Building Footprint Site Coverage - 9,500 sq ft iv. Driveway Area - 16,827 sq ft v. Walkways, Curbs, etc. Area - 1,833 sq ft A. Area Available for Landscaping - 38,887 sq ft A. Undevelopable Area - 17,055 sq ft viii. Developable Landscape Area Proposed - 21,832 sq ft ix. Landscape Units required 1 per 50 sq ft - 437 units x. Landscape Units Proposed - 448 units d. The Proposed Developable Landscape Area of 21,832 sq ft is greater than the minimum Required 25% of the entire lot of 16,762 sq ft. 1003_Danfas-Wlldstor_AEC_08'29-11.doo Page I of 2 Alternative Eauivalent Compliance mmpp design shop PO Box 288 095 Willowstone Place Gypsum, CO 81637 c 970-390-4931 michael@mr)odesianshoo.com 3. Bicycle Parking -Added September 27, 2011 a. We are requesting to be exempt from the requirements of §7.28.404(E)(5) and §7.28.020(j). b. We feel that the requirements for bicycle parking are intended for multi -family and commercial buildings. c. Our project consists of (8) single family homes each with their own driveway and two -car garage. (2) surface parking spaces and (2) covered parking spaces are provided for each house. Any visitor riding a bicycle, who will be visiting an individual home, or any home owner using a bicycle for commuting will be able to park a bicycle at the side of the house, in the driveway, or in the garage. Thank you for your consideration of these requests. SIGNED: Michael Pukas 1003_Dantas-Wlldstar_AEC _08-29-1 I.dac Page 2 of 2