Loading...
PZC Packet 0501181 Agenda posted on Friday, April 27, 2018 at the following public places within the Town of Avon: -Avon Municipal Building, Avon Recreation Center, Avon Public Library, Town of Avon Website www.avon.org Please call 970-748-4023 for questions. Planning & Zoning Commission Meeting Agenda Tuesday, May 1, 2018 If you require special accommodation please contact us in advance and we will assist you. You may call David McWilliams at 970- 748-4023 or email cmcwilliams@avon.org for special requests. I. Call to Order – 5:00pm II. Swearing in of new Commissioner Alex Dammeyer III. Roll Call IV. Additions & Amendments to the Agenda V. Conflicts of Interest VI. Major Development Plan and Alternative Equivalent Compliance – 4254 Wildridge Road West - CONTINUED PUBLIC HEARING File: MJR18002 and AEC18002 Legal Description: Lot 21A Block 3 Wildridge Applicant: Jeff Manley Summary: Proposal to construct a new single-family house. This project requires an Alternative Equivalent Compliance application for the roof pitch under 4:12. The applicant has requested this item be continued to the May 15, 2018 PZC meeting. VII. Major Development Plan and Alternative Equivalent Compliance– 4561 Flat Point - PUBLIC HEARING File: MJR18004 and AEC18005 Legal Description: Lot 32 Block 3 Wildridge Applicant: Jeff Manley Summary: Proposal to construct a new single-family house. This project requires an Alternative Equivalent Compliance application for the roof pitch under 4:12. VIII. IX. Action on Records of Decision • MJR18001 and AEC18001 – 4254 Wildridge Road West • REZ18003 – Colorado World Resorts X. Action on Meeting Minutes • April 17, 2018 PZC Minutes XI. Staff Updates • PZC Homework – read and review 15.28 Sign Code XII. Adjourn To: Planning and Zoning Commission From: David McWilliams, Town Planner Date: May 1, 2018 Agenda Topic: PUBLIC HEARING for cases MJR18002 and AEC18002, Major Development Plan and Alternative Equivalent Compliance Lot 21 A Block 3, Wildridge 4254 Wildridge Road West SUMMARY: The Planning and Zoning Commission continued this application from the April 17, 2018 meeting, in order to allow the applicant to modify the roof forms to complement the existing Avon Municipal Code. Now, the applicant is requesting that the application be continued again until the May 15, 2018 PZC meeting. Staff recommends that PZC open and close the Public Hearing, and then continue the hearing until that date. RECOMMENDED MOTION: “I move to Continue files #MJR18002 and AEC18002, a proposal for a single family house on Lot 21A Block 3 Wildridge Subdivision, until May 15, 2018.” May 1, 2018 PZC Meeting – 4561 Flat Point 1 Staff Report – Major Development Plan & AEC May 1, 2018 Planning and Zoning Commission Meeting Case #MJR18004 and AEC18005 Project type Major Development Plan and Alternative Equivalent Compliance Public Hearing Required Legal Description Lot 32 Block 3Wildridge Subdivision Zoning Planned Unit Development (PUD) Address 4561 Flat Point Prepared By David McWilliams, Town Planner Staff Report Overview This staff report contains two applications for consideration by the PZC: Major Development Plan with Design Review for a new proposed single-family house; and an Alternative Equivalent Compliance for the roof pitch under the required 4:12 pitch. Summary of Request Jeff Manley (the Applicant) with Martin Manley Architects proposes a new house for Lot 32. The building is 2 stories, 3,947 s.f. of livable space and includes an 841 s.f. garage. The lower level is ground level at the garage side and located below grade on the uphill side of the house. It has shed roofs mainly at 2:12. The proposal is best described as mountain modern style with large shed roofs. Public Notice Notice of the public hearing was published in the April 20 edition of the Vail Daily in accordance with Sec. 7.16.020(d) of the Avon Development Code. Mailed notice is not required for this application type. Property Description Lot 32 is .39 acres located at the end of Flat Point at the top of Wildridge. It is zoned PUD and would accommodate a duplex per the PUD standards. It borders duplex and single-family houses and two vacant lots on the street side. Planning Analysis Lot Coverage, Setback and Easements: Lot 31 has a traditional Wildridge building envelope and easements: Front Side Back Drainage Easement 25’ 7.5’ 10’ 10’ on each side Building Height: The maximum building height permitted for this property is thirty-five feet (35’). The applicant is proposing a maximum building height of twenty-nine feet two inches and 7/16” (29' – 2 -7/16”) according to the development plans. Parking: The project is required three parking spaces, which are provided between the garage and the spaces in front of the garage. May 1, 2018 PZC Meeting – 4561 Flat Point 2 Design Standards Analysis Landscaping & Irrigation: The building is proposed to be landscaped primarily with aspen, spruce, crabapple, several deciduous shrub species, native grasses, ground cover, and mulch areas (sheet A1.2, attachment B). The Landscape Unit count provided is 204, with 191 required. The application includes a 50% Landscape Unit bonus for having 80% or more of the landscape area on temporary irrigation, however, it is missing the area calculation that demonstrates qualification. Staff suggests that this can be presented as a condition of approval and staff reviewed before building permits will be issues. The applicant proposes 2,700 square feet of undisturbed landscape, thus qualifying for a 10% Landscape Unit bonus. Permanent irrigation is proposed with micro spray for ground cover and drip irrigation for the trees. Hydrozones are not expressly demarcated on the irrigation plan. Staff considers this oversight rectifiable through a condition of approval and a staff review of the revised plan. Building Design, Building Materials and Colors: The primary exterior building materials are wood siding (stained brown) and stone tiles (Attachment B, sheet A3.0). Colors were reviewed for conformance with Sec. 7.28.090(j)(4)(viii), Building Materials, and determined to comply with the design standards. All materials are of high quality and compliment Avon’s built landscape. Retaining Walls: All retaining walls are proposed as boulder materials. There is a retaining wall on the north radiating from the garage, one on the east side radiating from the side of the house, and two surrounding the south deck to create positive drainage. They are between four (4’) and two (2’) feet tall. Roof Material and Pitch: The roof material and pitch were reviewed for compliance with Sec. 7.28.090(d)(3) Roofs. The applicant is proposing primarily 2:12 roof pitches. Pitches are required to be 4:12 or above, therefore an Alternative Equivalent Compliance review is necessary, found below. Exterior Lighting: The proposed lighting (Attachment C), recessed bronze fixtures and walkway lighting, is Dark Sky Compliant, and the locations and quantity are found to be compliant with lighting code. Major Development Plan & Design Review - Review Criteria § 7.16.080(f), Development Plan 1. Evidence of substantial compliance with the purpose of the Development Code as specified in §7.04.030, Purposes; Staff Response: The Application is in compliance with the applicable purposes outlined in the Development Code. Purpose (a) states, “Divide the Town into zones, restricting and requiring therein the location, erection, construction, reconstruction, alteration and use of buildings, structures and land for trade, industry, residence and other specified uses; regulate the intensity of the use of lot areas; regulate and determine the area of open spaces surrounding such buildings; establish building lines and locations of buildings designed for specified industrial, commercial, residential and other uses within such areas; establish standards to which buildings or structures shall conform; establish standards for use of areas adjoining such buildings or structures.” 2. Evidence of substantial compliance with §7.16.090, Design Review; Staff Response: This Major Design and Development Plan Application should be assessed for May 1, 2018 PZC Meeting – 4561 Flat Point 3 compliance with the Design Review criteria of the Development Code. The Design Review section seeks quality development and structures that are visually harmonious with the site and the surrounding vicinity. Conformance with this code section is discussed below and in Staff Analysis. The roof pitch deviation from the Development Code is included for Alternative Equivalence Compliance review, below. 3. Consistency with the Avon Comprehensive Plan; Staff Response: The site is located in the Northern Residential District (District 11 of the Comprehensive Plan), which states, “Due to the limited number of existing trees and shrubs and the open character of the property, special care should be taken to ensure that all structures are compatible with one another and in harmony with the natural surroundings.” This District includes principles that encourage minimal alteration to the natural environment and steep slope development. This Application generally proposes a design that is consistent with the Goals and Policies contained in the Comprehensive Plan, including, “Policy G.2.1: Identify and avoid development in environmentally sensitive areas or steep hillsides.” 4. Consistency with any previously approved and not revoked subdivision plat, planned development, or any other precedent plan or land use approval for the property as applicable; Staff Response: The application is in conformance with the accompanying requirements of the PUD zoning and the Development Code. 5. Compliance with all applicable development and design standards set forth in this Code, including but not limited to the provisions in Chapter 7.20, Zone Districts and Official Zoning Map, Chapter 7.24, Use Regulations, and Chapter 7.28, Development Standards; and Staff Response: The analysis contained in this staff report addresses all applicable Development Code standards. 6. That the development can be adequately served by city services including but not limited to roads, water, wastewater, fire protection, and emergency medical services. Staff Response: The proposal was referred to the Eagle River Water and Sanitation District for compliance with the property’s’ water allocation, and received no comment. All special services are well established in the subdivision. §7.16.090(f), Design Review 1. The design relates the development to the character of the surrounding community; or, where redevelopment is anticipated, relates the development to the character of Avon as a whole; Staff Response: The Application proposes a design that relates to the character of the surrounding community. 2. The design meets the development and design standards established in this Development Code; and Staff Response: The design is either compliant with the development and design standards contained in the Development Code, or seeks an Alternative Equivalent Compliance. May 1, 2018 PZC Meeting – 4561 Flat Point 4 3. The design reflects the long-range goals and design criteria from the Avon Comprehensive Plan and other applicable, adopted plan documents. Staff Response: Applicable adopted plans include the Avon Comprehensive Plan and provisions of the Development Code. The design has been evaluated for conformance with these plans and staff has determined the proposed design meets the requirements as proposed. 7.16.120 - Alternative Equivalent Compliance Alternative equivalent compliance is a procedure that allows development to meet the intent of the design-related provisions through an alternative design. It is not a general waiver or weakening of regulations; rather, this application procedure permits a site-specific plan that is equal to or better than the strict application of a design standard specified in the Development Code. This procedure is not intended as a substitute for a variance or administrative modification or a vehicle for relief from standards in this Chapter. Alternative compliance shall apply only to the specific site for which it is requested and does not establish a precedent for assured approval of other requests. Review Criteria. The PZC shall use the following review criteria as the basis for a decision on an application for alternative equivalent compliance: 1. The proposed alternative achieves the intent of the subject design or development standard to the same or better degree than the subject standard; 2. The proposed alternative achieves the goals and policies of the Avon Comprehensive Plan to the same or better degree than the subject standard; 3. The proposed alternative results in benefits to the community that are equivalent to or better than compliance with the subject standard; and 4. The proposed alternative imposes no greater impacts on adjacent properties than would occur through compliance with the specific requirements of this Title. AEC Request Specific design components require AECs for PZC consideration: • The Application proposes a minimum roof pitch of 1.5:12, with the primary forms 2:12, instead of the required 4:12 (3:12 for metal) on the roof sections, in deviation of AMC sec. 7.28.090(d)(3)(i). The summary of the request can be found in Attachment D. Staff Analysis The intent of mandating a 4:12 pitch is to create an attractive angled shape of the roof , and a unified aesthetic throughout town. Snow loading is another concern that the Municipal Code seeks to avoid by prohibiting low-pitched roofs. Home styles such as ranch houses feature only low-pitched roofs. Staff is not suggesting that the applicant is proposing a ranch house, only that the ranch style typically contains this typology, which is not a favored style in Avon. The type of home proposed is best described as “mountain modern,” which generally favors a lower pitched roof, unique structure shape, and large windows and doors. Staff acknowledges the prevalence of different roof forms in the neighborhood, however, the majority of houses in the area seem to use 4:12 or higher pitch on all elements. The PZC is instructed to review the alternative for achieving the intent of the subject design standard, which is in part informed by the Purposes section of Avon Municipal Code. Section 7.04.030 states, “(l) Promote architectural design May 1, 2018 PZC Meeting – 4561 Flat Point 5 which is compatible, functional, practical and complimentary to Avon's sub-alpine environment.” The applicant states that the roof design helps achieve a reduced overall mass of the building and achieves a better use of interior space. The applicant further states that the design is “tucked” into the topography to reduce the apparent height. The maximum height is twenty-nine feet two inches and 7/16” (29' – 2 -7/16”) and does not approach the thirty-five-foot (35’) height limit. The house relies on shed roofs, which create abrupt forms and angles on the house. The primary roof is massive and has a 2:12 pitch which juts in front of the livable portion of the house to shelter a large deck. The most prominent view of the house will be akin to the top-left image of A0.0 in Attachment B, where the large shed roof overhang is the most pronounced. The second most prominent roofs sheds away from the primary roof but does not attach to it. Between the two roofs is a 1.5:12 sloping roof section that runs to the back of the house. Combined, these forms may overpower the neighboring houses and be impactful to the neighborhood aesthetic. Overall, staff is concerned that this AEC application may not achieve the intent of the Municipal Code to the same degree as the 4:12 regulation does. Staff is not opposed to pitches under 4:12 or the mountain modern aesthetic, but wants the design to favorably compliment the adjacent properties and surrounding community. The PZC should carefully assess the application for compliance with the review criteria, listed above. Staff has outlined a recommended motion for denial of the AEC request. A favorable motion for the Major Design and Development Plan application is also included. Staff Recommendation: Staff recommends denial of the Alternative Equivalent Compliance application for Lot 32 Block 3 Wildridge Subdivision with the following findings: Findings: 1. The proposed application was reviewed pursuant to §7.16.080(f), Development Plan, §7.16.090(f), Design Review, and §7.16.120 Alternative Equivalent Compliance; 2. The AEC does not achieve the intent of the roof design standard to the same or better degree than the subject standard, due to the abrupt forms and angles of the house; 3. The AEC does not achieve the goals and policies of the Avon Comprehensive Plan to the same or better degree than the roof design standards; 4. The AEC does not result in benefits to the community that are equivalent to or better than compliance with the roof design standards; and 5. The AEC imposes greater impacts on adjacent properties than would occur through compliance with the specific requirements of the Avon Development Code, due to the house overpowering adjacent properties. Recommended Motion: “I move to deny Case #AEC18005, an application for Alternative Equivalent Compliance for Lot 32 Block 3Wildridge Subdivision together with the findings of fact recommended by Staff.” Alternative Action on AEC18005 Alternative Equivalent Compliance: Motion for approval of the Alternative Equivalent Compliance application for Lot 32 Block 3 Wildridge Subdivision with the following findings: May 1, 2018 PZC Meeting – 4561 Flat Point 6 Findings: 1. The proposed application was reviewed pursuant to §7.16.080(f), Development Plan, 2. §7.16.090(f), Design Review, and §7.16.120 Alternative Equivalent Compliance; 3. The AEC achieves the intent of the roof design standard to the same or better degree than the subject standard; 4. The AEC achieves the goals and policies of the Avon Comprehensive Plan to the same or better degree than the roof design standards; 5. The AEC results in benefits to the community that are equivalent to or better than compliance with the roof design standards; and 6. By limiting the height of the building, the AEC imposes no greater impacts on adjacent properties than would occur through compliance with the specific requirements of the Avon Development Code. Motion to Approve the Application: “I move to approve Case #AEC18005, an application for Alternative Equivalent Compliance for Lot 32 Block 3 Wildridge Subdivision together with the findings of fact outlined by Staff.” Staff Recommendation for MJR18004 Major Design & Development Plan: Staff recommends continuing the Major Development Plan application for Lot 32 Block 3 Wildridge Subdivision to a later date, pending the outcome of an acceptable roof pitch. Recommended Motion: “I move to continue Case #MJR18004, an application for Major Design and Development Plan for 32 Block 3 Wildridge Subdivision pending the outcome of an acceptable roof design.” Alternative Action: Motion for approval of the Major Development Plan for Lot 32 Block 3 Wildridge, with the following findings and conditions: Findings: 1. The proposed application was reviewed pursuant to §7.16.080(f), Development Plan, §7.16.090(f), Design Review. The design meets the development and design standards established in the Avon Development Code; 2. The application is complete; 3. The application provides sufficient information to allow the PZC to determine that the application complies with the relevant review criteria; 4. The application complies with the goals and policies of the Avon Comprehensive Plan; 5. The demand for public services or infrastructure exceeding current capacity is mitigated by the application; and 6. The design relates the development to the character of the surrounding community; Conditions: 1. A satisfactory irrigation plan demonstrating square footage coverage and hydrozones shall be presented to staff before a building permit will be issues; and 2. Temporary irrigation systems must be removed upon sufficient vegetation establishment, which shall not exceed one (1) year for ground cover, two (2) years for shrubs or three (3) years for trees. May 1, 2018 PZC Meeting – 4561 Flat Point 7 Motion to Approve the Application: “I move to approve Case #MJR18004, an application for Major Design and Development Plan for 32 Block 3 Wildridge Subdivision together with the findings of fact outlined by Staff.” Exhibits A. Application Materials B. Design & Development Plans C. Lighting Plan D. AEC Application Materials Date: 04-12-2018 RE: 4561 Flat Point Residence narrative Town of Avon Planning staff and P & Z Board Martin Manley architects and SaltBox LLP, is proposing a single family residence at 4561 Flat Point in Wildridge Sub. Lot 32, Block 3. The lot is generally flat, for the Wildridge area. The site is located at the end of a cul-de-sac. The primary views are to the south, but it will be looking over the future development on a lot to the south of the cul-de-sac. The house is proposed to be 3,947.3 s.f. in livable area with an 841.4 s.f. garage. We positioned the house to take advantage of the views at the south and west sides of the home. The dining room and roof edge is aligned in a manner to relate to the street. A mountain modern design is created that has low slung roofs. This will the height lower and help the neighboring homes to look over. We have graded the home to take advantage of the outdoor spaces in creating a windward and leeward decks. Roof forms are primarily at 2:12, with one portion at 1.5:12 slope. The house has a mountain modern design that keeps with a use of traditional wood materials and colors in a contemporary building form. WE will be asking for Alternative Equivalent Compliance for the low roof pitches of 2:12 for pitch, and 1.5:12 pitch. Section 7.28.090 Design standards, (d) General Applicable Residential Design Standards: (3) Roofs: (i) states a minimum roof slope of 3:12 for metal roofs. The design of lower pitched roofs helps keep the overall scale if the building down. The height would be higher if the roof pitch was increased to the minimum 3:12 slope. We feel that this this design limits the overall height appearance of the residence. Thank you, Jeffrey P Manley AIA Martin Manley Architects 970-328-1299 (direct) 970-688-0326 (cell) www.martinmanleyarchitects.com Attachment A ZONING INFORMATION Lot 32 , Block 3, Wildridge Subdivision 4561 Flat Point Zoning: Duplex lot, Proposed Building Single Family Residence Lot 32 Area = .39 acres = 16,988.4 s.f. Maximum Lot Coverage Allowed = 50% of Lot Area 16,988.4= 8,494.2 s.f. Minimum Landscape Area Allowed = 25% of Lot Area 16,988.4= 4,247.1 s.f. Proposed Building Height= 29'-2 7/16" (<35'-0" allowed) Proposed Livable Area = 3,947.3 s.f. (23.2%) Proposed Garage Area = 841.5 s.f. Proposed Lot coverage by building/footprint =2,533.5 s.f. (14.9% of LOT) Proposed Impervious area (Building ) 2,533.5 s.f. + (drive + walks+ terrace) 2,185 s.f. = 4,718.5 s.f. total (27.8%) Proposed Landscape area (Lot area= 16,988.4 s.f.)-(imperv. 4,718.5 s.f.) = 12,269.9 s.f. Landscape area ( 72.2 %) Parking Requirements: 3 spaces required Snow Storage: 20 % of 1,850 s.f. Drive = 370 s.f. of snow storage Exterior Lighting: Dark sky compliant,970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject No.:DateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:23 PMA0.0COVER1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620Flat Point Single Family Planning and Zonning Set Saltbox 4561 Flat Point Avon Colorado, 81620 04-12-18 Parcel Number:1943-352-05-037 Location: Subdivision: Wildridge Block: 3 Lot: 32 4545 Flat Point, Avon CO 81620 Class of Work: New Construction Building Type: Single Family Residence Type of Construction: Type V-B Type of Occupancy: R3 Levels: 2-story Fire Sprinklers: No Monitored alarm system: Yes Heating: In-floor radiant heat Furnace/boiler: Min. 92% efficiency, GAS 2015 International Residential Code (IRC) including Appendix F & G 12" = 1'-0" ZONING SUMMARY CONSTRUCTION DOCUMENTS NOTE: THESE CONSTRUCTION DOCUMENTS INCLUDING ARCHITECTURAL SHEETS HAVE BEEN PREPARED IN RESPONSE TO THE SPECIFIC BASIC SERVICES REQUESTED BY THE OWNER CONTEMPLATING CONTINUED INVOLVEMENT, SELECTIONS AND DECISION MAKING BY THE GENERAL CONTRACTOR AND OWNER THROUGH COMPLETION OF CONSTRUCTION. THESE DOCUMENTS INDICATE THE SCOPE OF ARCHITECTURAL DESIGN CONCEPTS APPROVED BY THE OWNER AND INCLUDE DIMENSIONS OF THE BUILDING, THE TYPES OF STRUCTURAL SYSTEMS AND AN OUTLINE OF THE ARCHITECTURAL AND STRUCTURAL ENGINEERING ELEMENTS OF CONSTRUCTION. THESE CONSTRUCTION DOCUMENTS PROVIDE THE SCOPE OF SERVICES AS OUTLINED IN THE AGREEMENT FOR ARCHITECTURAL SERVICES AND THEREFORE DO NOT NECESSARILY INDICATE OR DESCRIBE ALL MATERIALS REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE WORK. IT IS THE UNDERSTANDING OF THE ARCHITECT AND ENGINEER THAT THE GENERAL CONTRACTOR SHALL FURNISH ALL WORK REQUIRED FOR PROPER COMPLETION OF THE WORK AND THAT THE WORK SHALL BE OF SOUND AND QUALITY CONSTRUCTION IN ACCORDANCE WITH INDUSTRY STANDARDS AND ALL MANUFACTURERS SPECIFICATIONS, INSTRUCTIONS, AND WARRANTY REQUIREMENTS. THE CONTRACTOR, BASED ON THE FOREGOING, SHALL PREPARE FOR OWNER REVIEW A REALISTIC BUDGET WITH A LATITUDE OF PRICES BASED ON ASSUMPTIONS OF SCOPE OF WORK AND OWNER PRODUCT SELECTIONS. CONTRACTOR'S RESPONSIBILITIES: THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS, CONSTRUCTION DOCUMENTS, STRUCTURAL DOCUMENTS, MUNICIPAL AND/OR COUNTY ZONING CODES, PERTINENT IRC 2009 CODE REQUIREMENTS, AND GENERAL SPECIFICATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MECHANICAL AND ELECTRICAL ENGINEERING, DESIGN, SPECIFICATIONS AND DRAWINGS AS REQUIRED FOR BUILDING PERMIT AND APPROVAL BY OWNER AND ARCHITECT. COLOR BOARD No.DescriptionDate1 3D View 3 2 3D View 1 PROJECT TEAM INFORMATION Owner: SALTCAT LLP Nick Salter PO BOX 2987 EDWARDS, CO 81632-2987 970-376-7258 Project Location: 4545 Flat Point, Avon CO 81620 Architect:Martin Manley Architect Jeffrey P Manley AIA PO Box 1587 Eagle, CO 81631 970.328.5151 jeff@martinmanleyarchitects.com General Contractor: Nick Salter PO BOX 2987 EDWARDS, CO 81632-2987 970-376-7258 Attachment B DN 1682.3 SF Lower Level Area 851.5 SF Garage Area 2265 SF Main Level Area 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:25 PMA0.1AREA CALCULATIONS1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620No.DescriptionDate1/8" = 1'-0"1 A1.0 LOWER LEVEL 1/8" = 1'-0"2 A2.0 MAIN LEVEL Area Schedule (LIVABLE) Name Area Main Level Area 2265 SF Lower Level Area 1682.3 SF Grand total: 2 3947.3 SF Area Schedule (GARAGE) Name Area Garage Area 851.5 SF Grand total: 1 851.5 SF Attachment B 8498 8 5 0 0 8 5 0 1 850284 95.42 84 97.25 8497.09 8496.19 8496.76 84 98.62 8500.25 85 0 2.2 0 8504.39 DEC ID UOUS TR EE WA T ER VA LVE EDG E OF AS PHA LT R OADWAY P HO NE PED. S EW ER M AN HO LE RIM ELEV. = 8 502.4 6' EDG E OF AS PHA LT DR I VEW AY 18" C.M.P . INVE RT IN = 849 3.81' S P A A T C O R D IL L E R A S P A A T C O R D IL L E R A NY MOUNTAINTOP OF ARROWHEADT O P O F B E L L Y A C H E8527.5'FOUND A PLAI N No . 5 REBAR (ELEV. = 85 05.8 6') F OU N D No . 5 REB AR WIT H AN A LUMIN UM CAP P.L.S. No. 5 447 (ELE V. = 8 502.11') 0.48 A C RES 454 5 FLA T P OI NT 0 .39 ACR E S 4 5 6 1 FL AT P OI N T L O T 3 1 L O T 3 2 L O T 3 3 L O T 3 3 U TILITY & DRAI NAGE EAS EME NT S LOPE MAI NTENANC E, DR AI NAGE & SNO W STORA GE E ASE MENT N 17°47'35" W - 129.64'N 25°26'01" S 86°57'12" E - 93.43' ∆=6 °08 '0 5 " R =3 2 6.8 8 ' L =3 5 .0 0 ' C hB =S 75 °1 6 '2 8"W C hL=3 4 .9 8 ' S 7 8 °2 0 '3 0 " W - 1 1 0 .9 4 'N 03°25'54" E - 160.00'8 4 9 6 8 4 9 5 84978 4 9 8 849984998 5 0 2 8503 8 5 0 4 8 5 0 0 8 5 0 185028 5 0 3 85048 5 1 4 8 5 1 3 8 5 1 2 8 5 1 1 8 5 1 085098 5 0 8 8 5 0 7 8506 8 5 0 58500849584948496849784988499850185028503 8500 8 5 0184988497 7 '-6 "10'-0"1 0 '-0 "25'-0"10'-0"10'-0"1 0 '-0 "10'-0"7'-6" 7 '-6 "W V P H PH S S DN T.O. WALL B.O. WALL 3'-0" 8499'-6" GUEST PARKING SILT FENCING ALONG THE DOWNHILL SIDE LIMITS OF DISTURBANCE FENCING 8497'-6"SILT FENCING ALONG THE DOWNHILL SIDE 8500' - 0" 8498' - 0" 8497' - 7 9/16" DECK AT MAIN LEVEL 8509' - 2" 8497' - 11 1/2" 8499' - 6" 8497' - 0"2.5%2.88%8499' - 0" 8498' - 0" 8497' - 6" T.O. WALL B.O. WALL 3'-0" 8504'-0" 8501'-0" T.O. WALL B.O. WALL 4'-0" 8504'-0" 8500'-0"0.25:120.25:120.26:120.26:120.26:12 8499' - 11" 8499' - 9 3/4" 96' 97' 98' 2700 s.f. of undisturbed area 99'00'01' 01' 02' 03' 04' 05' 06' 07' 08' 08'07'06' 05' 04' 03' 04' 02' 01' 00' 02' 01' 00' 00' 01' T.O. WALL B.O. WALL 2'-0" 8499'-0" 8497'-0" 00' 97' 00' 00' 00' 99' 99' 98' 98' 97' 96' 18" GALV. CULVERT GRADING AND DRIVE ACCESS IMPROVEMENTS OUTSIDE PROPERTY LINE ARE SUBJECT TO A RIGHT-OF-WAY PERMIT DURING CONSTRUCTION A 6" DEEP x 12' WIDE x A LENGTH OF 20' PROVIDE A GRAVEL TRACKING PAD AT THE ACCESS POINT TO THE SITE OPEN 8" DRAIN PIPE WITH INVERT AT 8496'-9" OPEN 8" DRAIN PIPE WITH OPENING AT 8495'-9"WATERGAS METER ELEC METER CONSTRUCTION FENCING AT LIMITS OF DISTRUBANCE CONSTRUCTION FENCING AT LIMITS OF DISTRUBANCE 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:26 PMA1.1SITE PLAN1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 816201" = 10'-0"1 A0.0 SITE PLAN True North Project North No.DescriptionDateAttachment B 8498 8 5 0 0 8 5 0 1 850284 95.42 84 97.25 84 97.09 8496.19 8496.76 84 98.62 8500.25 8 5 02.20 DEC ID UOUS TR EE EDG E OF AS PHA LT R OADWAY P HO NE PED. E D G E OF A S P HA L T D R I VEW A Y 1 8 " C.M .P . I N V E RT I N = 8 4 9 3.8 1 ' S P A A T C O R D IL L E R A NY MOUNTAINTOP OF ARROWHEADT O P O F B E L L Y A C H E8527.5'FOUND A PLAI N N o. 5 RE B AR (ELEV. = 85 05.8 6') FOUND No . 5 REB AR WITH AN A LUMIN UM CAP P.L.S. No. 5 447 (ELE V. = 8 502.11') 0.39 AC RES 456 1 FLAT P OI NT L O T 3 2 L O T 3 3 L O T 3 3 U TILITY & DRAI NAGE EAS EME NT S LOP E MAI NTENANC E, DR AI NAGE & S NO W STORA GE E ASE MENT N 17°47'35" W - 129.64'N 25°26'01" E - 1S 86°57'12" E - 93.43' ∆=6 °08 '0 5 " R =3 2 6.8 8 ' L =3 5 .0 0 ' C hB =S 75 °1 6 '2 8"W C hL=3 4 .9 8 ' S 7 8 °2 0 '3 0 " W - 1 1 0 .9 4 'N 03°25'54" E - 160.00'8 4 9 6 8 4 9 5 84978 4 9 8 849984998 5 0 2 8503 8 5 0 4 8 5 0 0 8 5 0 185028 5 0 3 8 5 1 3 8 5 1 2 8 5 1 1 851 0 85098 5 0 8 8 5 0 7 8506 8 5 0 58500849584948496849784988499850185028503 8500 8 5 0184988497 7 '-6 "10'-0"1 0 '-0 "25'-0"10'-0"10'-0"1 0 '-0 "10'-0"7'-6" 7 '-6 "P H PH S S DN T.O. WALL B.O. WALL 3'-0" 8499'-6" GUEST PARKING SILT FENCING ALONG THE DOWNHILL SIDE LIMITS OF DISTURBANCE FENCING 8497'-6"SILT FENCING ALONG THE DOWNHILL SIDE 8500' - 0" 8498' - 0" 8497' - 7 9/16" DECK AT MAIN LEVEL 8509' - 2" 8497' - 11 1/2" 8499' - 6" 8497' - 0"2.5%2.88%8499' - 0" 8498' - 0" 8497' - 6" T.O. WALL B.O. WALL 3'-0" 8504'-0" 8501'-0" T.O. WALL B.O. WALL 4'-0" 8504'-0" 8500'-0"0.25:120.25:120.26:120.26:120.26:12 8499' - 11" 96' 97' 98' 2700 s.f. of undisturbed area 99'00'01' 01' 02' 03' 04' 05' 06' 07' 08' 08'07'06' 05' 04' 03' 04' 02' 01' 00' 02' 01' 00' 00' 01' T.O. WALL B.O. WALL 2'-0" 8499'-0" 8497'-0" 00' 97' 00' 00' 00' 99' 99' 98' 98' 97' 96' 18" GALV. CULVERT GRADING AND DRIVE ACCESS IMPROVEMENTS OUTSIDE PROPERTY LINE ARE SUBJECT TO A RIGHT-OF-WAY PERMIT DURING CONSTRUCTION A 6" DEEP x 12' WIDE x A LENGTH OF 20' PROVIDE A GRAVEL TRACKING PAD AT THE ACCESS POINT TO THE SITE OPEN 8" DRAIN PIPE WITH INVERT AT 8496'-9" OPEN 8" DRAIN PIPE WITH OPENING AT 8495'-9" Q A Q A Q A Q A Q A Q AQ AQ AQ AQ A Q AQ AQ AFC LLS P S P S P S P S P S P LLLLLLLLLLLLLLLLLLC E C E C ECE C E C E C E C ECE C E C E C E CONSTRUCTION FENCING AT LIMITS OF DISTRUBANCE CONSTRUCTION FENCING AT LIMITS OF DISTRUBANCE CS CS Landscape and Irrigation table AREA MATRIX: Lot 32 , Wildridge Subdivision Zoning: Duplex lot, Proposed Building Single Family Residence Lot 32 Area = .39 acres = 16,988.4 s.f. Maximum Lot Coverage Allowed = 50% of Lot Area 16,988.4= 8,494.2 s.f. Minimum Landscape Area Allowed = 25% of Lot Area 16,988.4= 4,247.1 s.f. Proposed Building Height= 29'-2 7/16" (<35'-0" allowed) Proposed Livable Area = 3,947.3 s.f. (18.8%) Proposed Garage Area = 841.5 s.f. Proposed Lot coverage by building/footprint =2,533.5 s.f. (14.9% of LOT) Proposed Impervious area (Building ) 2,533.5 s.f. + (drive + walks+ terrace) 2,185 s.f. = 4,718.5 s.f. total (27.8%) Proposed Landscape area (Lot area= 16,988.4 s.f.)-(imperv. 4,718.5 s.f.) = 12,269.9 s.f. Landscape area ( 72.2 %) Proposed Temp Irrigation only in reveg. seeded areas. Landscape Units = 12,269.9 s.f. -2700 s.f. of undisturbed area= 9,569.9 / 50 s.f. per unit =191.4 units 25% Landscape Units to be provided be trees = 25% of 191.4 units =47.8 units by trees Landscape Material (trees)New Existing retained Units Deciduous 1.5" -2.5" caliper/clump = 4 units per tree X 7=28 4 units per tree X 0 =0 28 units Deciduous 2.5" -4" caliper/clump = 7 units per tree X 7=49 9 units per tree X 1 =9 58 units Evergreen 6'-8' high =6 units per tree X 2 =12 11 units per tree X 0=0 12 units Landscape Material (shrubs)New Existing retained Units Shrubs, 5 gallon = 1 unit per shrub X24 =24 1.2 units per shrub X 0 =0 24 units Perennial Ground covers Units 1 unit per 400 s.f. 400 s.f. proposed / 400 s.f.=1 units 1.0 units Hardscape Material Units Awarded calculation Units Shredded Bark (mulch at planting beds around trees)1/500 s.f. 500 s.f. planting bed area/500 =1 1 Units subtotal 124 units Retained Existing Vegetation Mass Bonus Landscape Units Awarded 300+ square feet of native Vegetation 10% Proposed Undisturbed Native vegetation Area = 900 s.f.< 300 s.f. Bonus to be applied 10 % of 124 units = 12.4 12.4units subtotal 136.4 units Drip Irrigation Bonus Landscape Units Awarded 80% or more of total landscaped area on temporary irrigation 50% 50 % of 136.4 units = 68.2 Bonus to be applied 68.2 units Total Landscape Units Proposed (191.4 required)204.6 units QA Deciduous Trees Count QUAKING ASPEN (POPULUS TREMULOIDES) 1.5" to 2.5" CAL. Size 6 14 Symbol Name Deciduous Shrubs LL DWARF KOREAN LILAC (SYRINGA MEYERI 'PALABIN') OR Fendler ceanothus, mountain-lilac #5.8 24 CE #5 10COTONEASTER DAMMERI CORAL BEAUTY (COTONEASTER DAMMERI) GC Perennial Ground covers 400 square feet of cover. CS Conifer Trees 6'-8' tall 2 2 Colorado Spruce (Picea pungens) Mulched Areas SHREDDED BARK MULCHED AREA -AROUND TREES AND SHRUBS NOT COVERED BY GROUND COVER Natural Grass Areas (reveg) MULCH NG GROUND COVER NATURAL GRASS AREA IRRIGATION NOTE: 1 ALL RESEEDED AREAS ARE TO TEMPORARY DRIP IRRIGATION 2 THE GROUND COVER AND PLANTING BEDS ARE TO RECIEVE PERMANENT MICRO SPRAY AND DRIP IRRIGATION TOTAL OF PERMANENT DRIP AND SPRAY IRRIGATION AREA OF 1,500 S.F. SNOW IN SUMMER, STONECROP, CREEPING PHLOX, NATIVE LOW -GROW GRASSES, ROCKY MTN. FESCUE 500 square feet of cover. Q A CS LLS P C E #5SP 6SPIREA, ANTHONY WATERER (Spiraea japonica ‘Anthony Waterer’) FC FRUITLESS FLOWERING CRABAPPLE (Malus 'Spring Snow' ) (15' TALL MATURE HT) 2" CAL.1 FC Q A MULCH Soil Amendment notes. (A) Topsoil of irrigated grasses (including turf), shrubs, perennials, and annuals shall be a sandy loam to a depth of at least six (6) inches containing at least five percent (5%) organic matter by volume. (B) Amended tree soil should have a minimum planting hole diameter of two (2) times as large as the root ball diameter. Both topsoil and subsoil layers shall be sandy loam. The topsoil shall be at least six (6) inches and have five percent (5%) organic matter by weight and subsoil shall have at least one to three percent (1 -3%) organic matter by weight. (C) A minimum of four (4) cubic yards of organic matter soil amendment per one-thousand square feet of landscaped area shall be required as necessary to meet the five percent (5%) organic matter specification. (D) In all disturbed areas for reveg reseeding, soil must be prepared with tilling and the addition of decomposed organic matter such as, but not limited to, compost, composted horse manure or composted chopped straw or hay. Straw tackifier or matting on steep slopes is required to prevent soil erosion. The addition of decomposed organic matter is also required prior to turf installation. GUARANTEE OF INSTALLATION.Required landscape improvements shall be installed prior to issuance of a certificate of occupancy for all structures. MAINTENANCE.All landscape improvements shall be maintained and replaced by the property owner as necessary. All property owners shall be responsible for maintenance of landscape improvements within the public ROW between the back of curb or street pavements and the adjacent property. 2.5" to 4" CAL.7 MIX OF GRASSES AND FESCUE SEED. ARKANSAS VALLEY SEED COMPANY, NATIVE LOW GROW MOUNTAIN MIX.A SPRAY MIX OF FERTILIZER AND SEED WILL BE APPLIED TO ALL DISTURBED AREAS OF THE SITE AND BE TEMPORARY DRIP IRRIGATED. Area = 8,500 s.f. approx Temporary Drip Irrigation as needed to establish 2.5" TO 4" 1.5" TO 2.5" 2"970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:27 PMA1.2LANSCAPE PLAN1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620No.DescriptionDate1" = 10'-0"1 A0.0 LANDSCAPE PLAN 12" = 1'-0" LANDSCAPE UNITS 1/8" = 1'-0" LANDSCAPE LEGEND Attachment B 8495.42 8497.25 84 97.09 8496.19 84 96.76 84 98.62 85 00.25 8 5 02.20 D EC IDUOUS TREE E DG E OF ASP HALT ROA DWAY PHO N E PE D. E DG E OF AS P H A LT DR I V E W AY 1 8" C.M .P . I N VE R T I N = 8 49 3 .81 ' S P A A T C O R D IL L E R A NY MOUNTAINTOP OF ARROWHEADT O P O F B E L L Y A C H E8527.5'F OUN D A PL AIN N o. 5 RE B AR (ELE V. = 8505 .8 6') FOUND No . 5 REB AR W IT H AN ALUM INUM CAP P .L.S. N o. 544 7 (ELE V. = 8 502.11') 0 .39 ACR ES 4 561 FLAT P OINT L O T 3 2 L O T 3 3 L O T 3 3 UTIL IT Y & DR AINAG E EASEMENT S LOPE MAI NTENANC E, DR AI NAGE & S NOW STORAG E EASEME NT N 17°47'35" W - 129.64'N 25°2S 86°57'12" E - 93.43' ∆=6 °0 8 '0 5 " R =3 2 6 .8 8' L =3 5 .0 0 ' C hB =S 75 °1 6 '2 8"W C hL=3 4 .9 8 ' S 7 8 °2 0 '3 0 " W - 1 1 0 .9 4 'N 03°25'54" E - 160.00'8 4 9 6 8 4 9 5 84978 4 9 8 849984998 5 0 2 8503 8 5 0 4 8 5 0 0 8 5 0 185028 5 0 3 8 5 1 3 8 5 1 2 8 5 1 1 8 5 1 085098 5 0 8 8 5 0 7 8506 8 5 0 58500849584948496849784988499850185028503 8500 8 5 0184988497 7 '-6 "10'-0"1 0 '-0 "25'-0"10'-0"10'-0"1 0 '-0 "10'-0"7'-6" 7 '-6 " P H P H S S DN SILT FENCING ALONG THE DOWNHILL SIDE LIMITS OF DISTURBANCE FENCING SILT FENCING ALONG THE DOWNHILL SIDE 8500' - 0" 8498' - 0" 8497' - 7 9/16" DECK AT MAIN LEVEL 8509' - 2" 8497' - 11 1/2" 8497' - 0" 8499' - 0" 8498' - 0" 8497' - 6"0.25:120.25:120.26:120.26:120.26:12 8499' - 11" 96' 97' 98' 2700 s.f. of undisturbed area 99'00'01' 01' 02' 03' 04' 05' 06' 07' 08' 08'07'06' 05' 04' 03' 04' 02' 01' 00' 02' 01' 00' 00' 01' 00' 00' 00' 00' 99' 99' 98' 98' 97' 96' 18" GALV. CULVERT GRADING AND DRIVE ACCESS IMPROVEMENTS OUTSIDE PROPERTY LINE ARE SUBJECT TO A RIGHT-OF-WAY PERMIT DURING CONSTRUCTION A 6" DEEP x 12' WIDE x A LENGTH OF 20' PROVIDE A GRAVEL TRACKING PAD AT THE ACCESS POINT TO THE SITE OPEN 8" DRAIN PIPE WITH INVERT AT 8496'-9" OPEN 8" DRAIN PIPE WITH OPENING AT 8495'-9" Q AQ A Q A Q A Q AQ A Q AQ AQ AQ A Q AQ A Q AQ AQ AQ A FC LLS P S P S P S P S P S P LLLLLLLLLLLLLLLLLLC E C E C ECE C E C E C E C E AC CONTROLLER VALVE ASSEMBLYSLEEVE UNDER DRIVE PERMANENT MICROSPRAY IRRIGATION PERMANENT DRIP IRRIGATION PERMANENT MICROSPRAY IRRIGATION PERMANENT DRIP IRRIGATION CONSTRUCTION FENCING AT LIMITS OF DISTRUBANCE CONSTRUCTION FENCING AT LIMITS OF DISTRUBANCE THE IRRIGATION SYSTEM SHALL BE DESIGNED BY THE LANDSCAPE SUBCONTRACTOR. The design shall: (A) Prevent runoff, low head drainage, overspray, or other similar conditions where irrigation water flows onto non- targeted areas, such as adjacent property, non-irrigated areas, hardscapes, roadways, or structures. Restrictions regarding overspray and runoff may be modified if the landscape area is adjacent to permeable surfacing and no runoff occurs or if the adjacent non-permeable surfaces are designed and constructed to drain entirely to landscaping. (B) Conform to the hydrozones of the landscape design plan. (C) Have matched precipitation rates within a hydrozone, unless otherwise directed by the manufacturer's recommendations. (D) Meet the required operating pressure of the emission devices using valve pressure regulators, sprinkler head pressure regulators, inline pressure regulators, booster pumps, or other devices. The pressure and flow measurements identified at the design stage will be verified prior to the installation of the system. (E) Meet the requirements set in the American National Standards Institute (ANSI) standard, ASABE/ICC 802-2014 "Landscape Irrigation Sprinkler and Emitter Standard authored by the American Society of Agricultural and Biological Engineers and the International Code Council and verified by an independent third-party. (F) (not applicable-no turfgrass proposed) Achieve the highest possible sprinkler spacing distribution uniformity using the manufacturer's recommendations. All sprinkler head installed in the turfgrass areas shall have a distribution uniformity of 0.65 or higher using the protocol defined in ASABE/ICC 802-2014 standard. IRRIGATION NOTE: 1 ALL RESEEDED AREAS ARE TO TEMPORARY DRIP IRRIGATION 2 THE GROUND COVER AND PLANTING BEDS ARE TO RECIEVE PERMANENT MICRO SPRAY AND DRIP IRRIGATION TOTAL OF PERMANENT DRIP AND SPRAY IRRIGATION AREA OF 1,500 S.F. 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:27 PMA1.3IRRIGATION PLAN1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620No.DescriptionDate1" = 10'-0"1 A0.0 IRRIGATION PLAN 12" = 1'-0" IRRIGATION NOTES Attachment B 84 95.42 8497.25 8497.09 84 96.19 84 96.76 8498.62 8500.25 85 0 2.2 0 85 04.39 DEC ID UOUS TR EE W ATER VA LVE E DG E OF ASP HALT R OADWAY PHO N E PE D. SEWER M AN HO LE RIM ELEV. = 8 502.4 6' E DG E OF ASP HALT DR I VEW AY 1 8" C.M .P. INVE RT IN = 849 3.81' S P A A T C O R D IL L E R A S P A A T C O R D IL L E R A NY MOUNTAINTOP OF ARROWHEADT O P O F B E L L Y A C H E8527.5'FOUND A PLAI N No . 5 REBAR (ELE V. = 8505 .8 6') F OU ND No. 5 R EB AR W IT H AN ALUM INUM CAP P.L.S. No. 5 447 (ELEV. = 8 50 2.1 1 ') 0.48 AC RES 454 5 FLA T P OI NT 0 .39 ACR E S 4 56 1 F LA T P OI NT L O T 3 1 L O T 3 2 L O T 3 3 L O T 3 3 UTIL IT Y & DR AINAG E EAS EME NT SLO PE M AINTE NANC E, DR AINA GE & S NOW STORAG E EASEME NT N 17°47'35" W - 129.64'N 25°26'01"S 86°57'12" E - 93.43' ∆=6 °08 '0 5 " R =3 2 6 .8 8' L =3 5 .0 0 ' C h B=S 7 5 °1 6 '2 8 "W C h L =3 4 .9 8 ' S 7 8 °2 0 '3 0 " W - 1 1 0 .9 4 'N 03°25'54" E - 160.00'8 4 9 6 8 4 9 5 84978 4 9 8 849984998 5 0 2 8503 8 5 0 4 8 5 0 0 8 5 0 185028 5 0 3 85048 5 1 4 8 5 1 3 8 5 1 2 8 5 1 1 851 0 85098 5 0 8 8 5 0 7 8506 8 5 0 58500849584948496849784988499850185028503 8500 8 5 0184988497 7 '-6 "10'-0"1 0 '-0 "25'-0"10'-0"10'-0"1 0 '-0 "10'-0"7'-6" 7 '-6 " W V PH P H S S DN SILT FENCING ALONG THE DOWNHILL SIDE LIMITS OF DISTURBANCE FENCING SILT FENCING ALONG THE DOWNHILL SIDE 8500' - 0" 8498' - 0" 8497' - 7 9/16" DECK AT MAIN LEVEL 8509' - 2" 8497' - 11 1/2" 8497' - 0" 8499' - 0" 8498' - 0" 8497' - 6"0.25:120.25:1296' 97' 98' 99'00'01' 01' 02' 03' 04' 05' 06' 07' 08' 08'07'06' 05' 04' 03' 04' 02' 01' SEWER 02' 01' 00' 00' 01' 00' 97' 00' 00' 00' 99' 99' 98' 98' 97' 96' 18" GALV. CULVERT GRADING AND DRIVE ACCESS IMPROVEMENTS OUTSIDE PROPERTY LINE ARE SUBJECT TO A RIGHT-OF-WAY PERMIT DURING CONSTRUCTION A 6" DEEP x 12' WIDE x A LENGTH OF 20' PROVIDE A GRAVEL TRACKING PAD AT THE ACCESS POINT TO THE SITE OPEN 8" DRAIN PIPE WITH INVERT AT 8496'-9" OPEN 8" DRAIN PIPE WITH OPENING AT 8495'-9" TLT J O B S I G N A G EDUMPSTER S O I L S T O C K P I L E MATERIAL STAGING AND STORAGE IN DRIVE AND IN GARAGE S O I L S T O C K P I L E SEWER SEWER SEWERSEWERELEC METER W A T E R W A T E R WATERELECELECELECELECWATERWATERGAS METER PHONE/CABLEPHONE/CABLEPHONE/CABLEP H O N E /C A B L E P H O N E /C A B L E P H O N E /C A B L E CONSTRUCTION FENCING AT LIMITS OF DISTRUBANCE CONSTRUCTION FENCING AT LIMITS OF DISTRUBANCE 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:28 PMA1.4CONSTRUCT. MGMT1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620No.DescriptionDate1" = 10'-0"1 A0.0 CONSTRUCTION MGMT PLAN Attachment B 8 5 0 1 85028 4 9 5 .4 2 8 4 9 7 .2 5 E D G E O F A S P H A L T D R I V E W A Y 0 .3 9 A C R E S 4 5 6 1 F L A T P O I N T U TI L I T Y & D R A I N A G E E A S E M E N T N 03°25'54" E - 160.00'850210'-0" 1 0 '-0 "7'-6" A3.0 A3.1 A3.12 A3.0 1 1 2 13' - 11"5' - 6"12' - 5 1/2"1' - 1 1/2"1 A4.0 1 A4.0 7' - 8 1/2"3' - 3 1/2"tv 18' - 5" 5 1 /2 " 1 3 ' - 5 1 /2 " 5 ' - 6 "14' - 0"5' - 2"3' - 0"3' - 6"32' - 8"2' - 0"24' - 0"9' - 6"13' - 10 1/2"4' - 8"2' - 7"14' - 3"1' - 1 1/2" 13' - 11 1/2"12' - 6 1/2"Mech Mud Entry Garage Bdrm #1 Bdrm #2 Bdrm #3 Family d r y b a r 2 A4.0 3 A4.0 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:29 PMA2.0LOWER LEVEL PLAN1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620Project North No.DescriptionDate1/4" = 1'-0"1 A1.0 LOWER LEVEL Attachment B 8 5 0 1 8 4 9 5 .4 2 8 4 9 7 .2 5 E D G E O F A S P H A L T D R I V E W A Y 0 .3 9 A C R E S 4 5 6 1 F L A T P O I N T L O T 3 2 N 03°25'54" E - 160.00'850084978498849985018502850310'-0" 1 0 '-0 "7'-6" DN DN DN A3.1 A3.12 A3.0 1 2 8509' - 0" 1 A4.012' - 8"17' - 2 1/2"6' - 4" 8511' - 6"8509' - 0" 8500' - 0" 8509' - 0" 8509' - 2" 8509' - 2"8509' - 2"12' - 0"9' - 6"23' - 6 1/2"9' - 5 1/2"9' - 0"5' - 9"4' - 0"6' - 0"8' - 1"4' - 6 1/2"8' - 5 1/2"17' - 8"6' - 4"9' - 11 1/2"7' - 4"4' - 6 1/2"11' - 5 1/2"23' - 4"2 A4.0 8515' - 0" 8510' - 1" 3 A4.0 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:30 PMA2.1MAIN LEVEL PLAN1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620Project North No.DescriptionDate1/4" = 1'-0"1 A2.0 MAIN LEVEL Attachment B 8 5 0 1 85028 4 9 5 .4 2 8 4 9 7 .2 5 E D G E O F A S P H A L T D R I V E W A Y 0 .3 9 A C R E S 4 5 6 1 F L A T P O I N T L O T 3 2 U TI L I T Y & D R A I N A G E E A S E M E N T N 03°25'54" E - 160.00'8 5 0 58508484984998585028503 10'-0" 1 0 '-0 "7'-6" 7 '-6 "DN A3.0 A3.1 A3.12 A3.0 1 1 2 2:12 2:12 1.5:122:12 2 A4.0 NAT GRADE =8501'-6" NEW GRADE =8499'-6" RIDGE ELEV RIDGE HT.=28'-2 7/16" 00' 00' 99' 98'8497' - 7 9/16" 8524' - 10 1/16" 8527' - 8 7/16" 8527' - 8 7/16" 8527' - 8 7/16" NAT GRADE =8500'-6" RIDGE ELEV RIDGE HT.=27'-2 3/8" 8525' - 1" 8526' - 9" NAT GRADE =8500'-9" NEW GRADE =8499'-11" RIDGE ELEV RIDGE HT.=26'-10" NAT GRADE =8501'-0" NEW GRADE =8499'-9" RIDGE ELEV RIDGE HT.=25'-4"1.5:122:12 NAT GRADE =8499'-6" RIDGE ELEV RIDGE HT.=27'-3" 8526' - 9" 99' 01' 04' 07' NAT GRADE =8499'-6" NEW GRADE =8504'-0" RIDGE ELEV RIDGE HT.=15'-6" 8515' - 0" 8510' - 1" 8520' - 2" NAT GRADE =8503'-6" NEW GRADE =8505'-1" EAVE ELEV EAVE HT.=16'-8" 8518' - 9 3/4" NAT GRADE =8502'-6" NEW GRADE =8500'-6" EAVE ELEV EAVE HT.=18'-3 3/4" 8522' - 8" NAT GRADE =8497'-6" NEW GRADE =8499'-0" EAVE ELEV EAVE HT.=25'-2" 3 A4.0 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:30 PMA2.2ROOF PLAN1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620No.DescriptionDate1/4" = 1'-0"1 ROOF PLAN Project North Attachment B A2.0 MAIN LEVEL 8509' -0" A3.0 MASTER LEVEL 8511' -6" Plate Height 8521' -10" A1.0 LOWER LEVEL 8498' -0" A1.5 GARAGE 8500' -0" Plate Height-Main 8519' -4"10' - 4"11' - 0"2' - 6"2' - 0"11' - 6"2:12 2 :1 2 2 :1 2 16' - 8"26' - 9"29' - 8 7/16"8502' - 6" 8503' - 6" 8501' - 6"8501' - 9" 8499' - 0" 8500' - 6" 8496' - 6" existing grade 8501' - 0" 8499' - 9 1/2" 8497' - 7 9/16" 8500' - 0" 1x8 VERTICAL T&G OR SHIP LAPPED WOOD SIDING ALUMINUM CLAD WOOD WINDOWS STANDING SEAM METAL ROOFING SYSTEM ON FULL COVERAGE HIGH TEMP WAERPROOF MEMBRANE ON ROOF SHEATHING ON RAFTERS ALUMINUM FASCIA (COLOR MATCHED TO ROOFING) 30"x18" STONE TILES WITH THIN MORTAR JOINTS AND 3" STONE CAP OF MATCHING MATIERAL EXPOSED STEEL BEAM AND COLUMN (PAINTED FLAT BLACK) 1X8 (6" EXPOSED FACE) HORIZONTAL BEV-LAP/CLAPBOARD WOOD SIDING 1X6 T&G WOOD SOFFIT 1x8 VERTICAL T&G OR SHIP LAPPED WOOD SIDING ADDRESS NUMBERS WOOD CLADD DOORS WITH ALUM. FRAMED TOP GLASS PANEL ELEC METER ON SIDE OF GARAGE HORIZONTAL 1X8 MATERIAL AND VERTICAL JAMBS AROUND GARAGE DOOR, MATCHING COLOR OF VERTICAL SIDING 2x CORNER BOARD AT HORIZONTAL SIDING LOCATIONS 3 1/2" WOOD TRIM (WIDTH) WITH PROUD HEAD TRIM (FLASHING ABOVE ALL WINDOWS) (3) RECESSED LIGHT FIXTURE IN SOFFIT ABOVE GARAGE DOORS FLASHING AT WOOD TO STONE CAP TRANSITION A2.0 MAIN LEVEL 8509' -0" A3.0 MASTER LEVEL 8511' -6" A1.0 LOWER LEVEL 8498' -0" A1.5 GARAGE 8500' -0" 2 A4.0 11' - 0"11' - 6"2' - 6"2' - 0"ELEC METER GAS METER2:122:121 .5 :1 2 2:12W12X26 8496' - 6" 8499' - 0" E X I S T I N G G R A D E 8501' - 0" 8502' - 0"EXISTING GRADE 3 A4.0 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:35 PMA3.0EXTERIOR ELEVATIONS1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620No.DescriptionDate1/4" = 1'-0"1 SOUTH ELEVATION 1/4" = 1'-0"2 WEST ELEVATION Attachment B A2.0 MAIN LEVEL 8509' -0" A2.0 MAIN LEVEL 8509' -0" A3.0 MASTER LEVEL 8511' -6" A1.0 LOWER LEVEL 8498' -0" A1.0 LOWER LEVEL 8498' -0" A1.5 GARAGE 8500' -0" 8509' - 2" 8499' - 0" 8496' - 6" 8507' - 6" 8501' - 0" 8499' - 6" 8503' - 6" 2 :1 2 1.5:122:12 2:12 LARGE AWNING WOOD DECK WITH STEP TO GRADE AT EDGES 8501' - 0" 8505' - 1" BOULDER RETAINING A2.0 MAIN LEVEL 8509' -0" A2.0 MAIN LEVEL 8509' -0" A3.0 MASTER LEVEL 8511' -6" Plate Height 8521' -10" A1.0 LOWER LEVEL 8498' -0" A1.0 LOWER LEVEL 8498' -0"11' - 0"10' - 4"2' - 6"A1.5 GARAGE 8500' -0" Plate Height-Main 8519' -4" 2 A4.0 2:122:122:121.5:12 2:122:128500' - 10 1/2" 8506' - 0" 8507' - 6"2"1' - 6"8503' - 6" 8502' - 9" 8499' - 6" 8501' - 3" EXISTING GRADE EXISTING GRADE17' - 11 1/8"3 A4.0 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:39 PMA3.1EXTERIOR ELEVATION1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620No.DescriptionDate1/4" = 1'-0"1 NORTH ELEVATION 1/4" = 1'-0"2 EAST ELEVATION Attachment B A2.0 MAIN LEVEL 8509' -0" A3.0 MASTER LEVEL 8511' -6" A1.0 LOWER LEVEL 8498' -0" A1.5 GARAGE 8500' -0" Plate Height-Main 8519' -4" 15' - 9 1/4"20' - 8 3/4" A2.0 MAIN LEVEL 8509' -0" A3.0 MASTER LEVEL 8511' -6" Plate Height 8521' -10" A1.0 LOWER LEVEL 8498' -0" A1.5 GARAGE 8500' -0" Plate Height-Main 8519' -4"10' - 4"8501' - 6"3' - 0"A2.0 MAIN LEVEL 8509' -0" A1.0 LOWER LEVEL 8498' -0" A1.5 GARAGE 8500' -0" Plate Height-Main 8519' -4"970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONSNOT FOR CONSTRUCTION4/11/2018 4:26:40 PMA4.0BUILDING SECTIONS1803Flat Point Single FamilyPlanning and Zonning Set04-12-18Saltbox4561 Flat PointAvon Colorado, 81620No.DescriptionDate1/4" = 1'-0"1 BUILDING SECTION THRU STAIR AND MASTER BEDROOM 1/4" = 1'-0"2 BUILDING SECTION AT LIVING ROOM LOOKING NORTH 1/4" = 1'-0"3 BUILDING SECTION AT LIVING ROOM LOOKING SOUTH Attachment B Date: 04-12-18 RE: Exterior lighting locations 4561 Flat Point, Lot 32, Attachment C Attachment C Cart - 0 itemsWhat are you shopping for?Search Brands LBL Lighting Wall Sconces LBL Lighting OD1015LEDWDW LBL Lighting OD1015GRPLEDWDW Graphite Quadrate 13" Tall Integrated LED Outdoor Wall Sconce Item # bci3060991 Model # OD1015GRPLEDWDW Quadrate Collection Click to Zoom Return Policy Buy Now, Take 12 Months to Pay On orders of $1,000 or more With the Build.com Credit Card Apply Now LBL Lighting Spring Black Friday Sale Save 15% on all LBL Lighting. No coupon required. Prices already reduced. Offer Ends 04-18-2018 $116.96 Originally $258.00, You Save 55% 5 Finish: Graphite Free Shipping! Write a Review Special Order Would you like to be notified when this is in stock? Enter Email Address Notify Me Leaves the Warehouse in 2 to 3 weeks (Change Zip) Quantity: 1 Add to Cart People Who Viewed LBL Lighting OD1015LEDWDW Also Viewed Attachment C LBL Lighting OD10… (0) Starting at $82.96 LBL Lighting OD10… (0) Starting at $97.24 LBL Lighting OD10… (0) Starting at $142.80 Modern Forms WS-… (0) Starting at $179.00 Modern Forms WS-… (0) Starting at $159.00 Kichler 9244 (9) Starting at $75.65 Specifications Reviews Product Q&A Features • Color temperature dimming from 2200K - 3000K • Durable aluminum construction • Includes (2) 16 watt Integrated LED lighting • Capable of being dimmed • ETL rated for wet locations • Compliant with California Title 24 energy standards • Protected by a 5 year manufacturer warranty Dimensions • Height: 13" • Width: 5" • Depth: 4-13/16" • Extension: 4-13/16" • Product Weight: 3.1 lbs • Backplate Height: 13" • Backplate Width: 5" • Backplate Depth: 1-1/2" Electrical Specifications • Bulb Base: Integrated LED • Number of Bulbs: 2 • Bulbs Included: Yes • Watts Per Bulb: 8 watts • Wattage: 16 watts • Voltage: 120 volts • Color Temperature: 2200K - 3000K • Color Rendering Index: 90CRI • Average Hours: 35000 • Lumens: 383 Additional LBL Lighting Links • View the Manufacturer Warranty • Browse All LBL Lighting Products • LBL Lighting Quadrate Collection This product is listed under the following manufacturer number(s): *Denotes a finish or option that has been discontinued. • LBL Lighting OD1015BZLEDWDW* Bronze • LBL Lighting OD1015GRPLEDWDW Graphite Manufacturer Resources Specification Sheet Related LBL Lighting Categories LBL Pendants LBL Lighting Monrail LBL Lighting Bathroom Lights LBL Wall Sconces LBL Lighting Chandeliers LBL Ceiling Lights LBL Lighting Outdoor Lights Overview Attachment C Cart - 0 itemsWhat are you shopping for?Search Brands Lithonia Lighting Shop All Lithonia Lighting LK3GORB LED LPI M6 Lithonia Lighting LK3GORB LED LPI M6 Bronze Gimbal Recessed Kit 3" GU10 Adjustable Recessed Trim with CRI 80 Item # bci2635839 Model # LK3GORB LED LPI M6 Gimbal Recessed Kit Collection Click to Zoom Return Policy Buy Now, Take 12 Months to Pay On orders of $1,000 or more With the Build.com Credit Card Apply Now Save up to 45% during the April SPRING BLACK FRIDAY sales event Take advantage of every day low Prices. Prices already reduced. Offer Ends 04-30-2018 $26.59 Originally $40.00, You Save 34% 5 Finish: Bronze Free Shipping on orders over $49.00! Write a Review 1275 In Stock Leaves the Warehouse in 1 to 3 business days (Change Zip) Quantity: 1 Add to Cart People Who Viewed Lithonia Lighting LK3GORB LED LPI M6 Also Viewed Globe Electric 90964 (0) Starting at $41.25 Lithonia Lighting L… (0) Starting at $23.98 Globe Electric 90712 (0) Starting at $10.38 Lithonia Lighting L… (0) Starting at $12.20 Globe Electric 90733 (1) Starting at $77.50 Globe Electric 91144 (0) Starting at $19.25 Attachment C Specifications Reviews Product Q&A Features • Gimbal trim allows light to be directed almost any direction • Fully assembled fixture with no need to purchase a trim and housing separately • Housing is not ic-rated • Includes (1) 4.5 watt GU10 LED bulb • Capable of being dimmed • CSA rated for damp locations • Includes 3 years manufacturers warranty Dimensions • Height: 6" • Width: 4" • Depth: 7-1/8" • Product Weight: 1.3 lbs Electrical Specifications • Bulb Type: LED • Bulb Shape: MR16 • Bulb Base: GU10 • Number of Bulbs: 1 • Bulb Included: Yes • Watts Per Bulb: 4.5 watts • Wattage: 4.5 watts • Voltage: 120 volts • Color Temperature: 3000K • Color Rendering Index: 80CRI • Average Hours: 25000 • Lumens: 300 • Beam Spread: 30° Additional Lithonia Lighting Links • View the Manufacturer Warranty • Browse All Lithonia Lighting Products • Lithonia Lighting Gimbal Recessed Kit Collection This product is listed under the following manufacturer number(s): • Lithonia Lighting LK3GORB LED LPI M6 Bronze Manufacturer Resources Specification Sheet Related Lithonia Lighting Categories Lithonia Lighting Clearance Sale Lithonia Ceiling Lighting Lithonia Track Lighting Lithonia Lighting Troffers Lithonia Lighting Shop Lights Lithonia Lighting Linear Fluorescent and LED Lithonia Flood Lights Overview Attachment C Date: 04-12-2018 RE: AEC for 4561 Flat Point, Lot 32 Avon Community Dev. Planning Dept. and Planning and Zoning Board C/O David McWilliams Town of Avon The Project at 4561 Flat Point, Lot 32, will be asking for Alternative Equivalent Compliance for the low roof pitch and height. Section 7.28.090 Design standards, (d) General Applicable Residential Design Standards: (3) Roofs: (i) states a minimum roof slope of 4:12 and metal roofs of 3:12. The design of lower pitched roofs helps keep the overall scale if the building down. We feel that this this design with the low sloped roofs limit the overall height appearance of the residence. The following is a response to the Review Criteria. The review authority shall use the following review criteria as the basis for a decision on an application for alternative equivalent compliance: (1) The proposed alternative achieves the intent of the subject design or development standard to the same or better degree than the subject standard; Under Design Standards for Wildridge, the code reads: (1) Intent: (i) To preserve and enhance the aesthetic qualities of the natural hillsides by designing projects which relate to the slope of the land and minimize the amount of project grading; and (ii) To promote development which is visually compatible with the natural topography of the surrounding area. Response: The roofs are proposed to be at 2:12 and at 1.5:12 to keep the overall mass of the building lower. The development code’s design standard at 4:12 pitch and 3:12 for metal roof would make for an increase of building mass and larger wasted interior volumes. The design is tucked into the topography or positioned to reduce a tall appearance of the building. Using the flatter pitched roof forms (1.5:12 and 2:12 pitch) will make the mass overall smaller and more compatible with the natural site. (2) The proposed alternative achieves the goals and policies of the Avon Comprehensive Plan to the same or better degree than the subject standard; Response: The proposed AEC achieves the goals and policies by creating lower roof/smaller building mass, than would be achievable under the design standard of 3:12. (3) The proposed alternative results in benefits to the community that are equivalent to or better than compliance with the subject standard; and Response: The proposed AEC benefits the community by creating lower roof/smaller building mass, than the design standard. This allows neighboring homes to see over/past the project and better preserve their views to the south and west. (4) The proposed alternative imposes no greater impacts on adjacent properties than would occur through compliance with the specific requirements of this Title. Response: The proposed AEC creates less impact to the properties since the home has lower roofs and less overall mass. Thank you, Jeffrey P Manley AIA Martin Manley Architects 970-328-1299 (direct) 970-688-0326 (cell) www.martinmanleyarchitects.com Attachment D PZC Record of Decision: #MJR18001 & AEC18001 Page 1 of 2 PLANNING AND ZONING COMMISSION FINDINGS OF FACT AND RECORD OF DECISION DATE OF DECISION: April 17, 2018 TYPE OF APPLICATION: Major Development Plan & Alternative Equivalent Compliance PROPERTY LOCATION: Lot 21A Wildridge Subdivision FILE NUMBER: #MJR18001 and #AEC18001 APPLICANT: Jeff Manley CASE #AEC18001 This Record of Decision is made in accordance with the Avon Development Code (“Development Code”) §7.16.120(b): DECISION: Approval of the development plan with the following findings: FINDINGS: 1. The proposed application was reviewed pursuant to §7.16.080(f), Development Plan; §7.16.090(f), Design Review, and §7.16.120 Alternative Equivalent Compliance; 2. The application is complete; 3. The application provides sufficient information to allow the PZC to determine that the application complies with the relevant review criteria; 4. Through the street-facing elements of the roof form, the AEC achieves the intent of the roof design standard to the same or better degree than the subject standard; 5. The AEC achieves the goals and policies of the Avon Comprehensive Plan to the same or better degree than the subject standard; 6. The AEC results in benefits to the community that are equivalent to compliance with the roof design standards; and 7. The AEC imposes no greater impacts on adjacent properties than would occur through compliance with the specific requirements of the Avon Development Code. CASE #MJR18001 This Record of Decision is made in accordance with the Avon Development Code (“Development Code”) §7.16.080(c): DECISION: Approval of the development plan with the following findings and conditions: FINDINGS: 1. The proposed application was reviewed pursuant to §7.16.080(f), Development Plan, §7.16.090(f), Design Review. The design meets the development and design standards established in the Avon Development Code; PZC Record of Decision: #MJR18001 & AEC18001 Page 2 of 2 2. The application is complete; 3. The application provides sufficient information to allow the PZC to determine that the application complies with the relevant review criteria; 4. The application complies with the goals and policies of the Avon Comprehensive Plan; 5. The demand for public services or infrastructure exceeding current capacity is mitigated by the application; and 6. The design relates the development to the character of the surrounding community. CONDITION: 1. If an updated survey positively confirms encroachments, turf grass on the north edge of Lot 21A shall be removed and replaced with unirrigated native seed; and 2. Temporary irrigation systems must be removed upon sufficient vegetation establishment, which shall not exceed one (1) year for ground cover, two (2) years for shrubs or three (3) years for trees. THESE FINDINGS OF FACT AND RECORD OF DECISION ARE HEREBY APPROVED: BY:______________________________________ DATE: ___________________ PZC Chairperson PZC Record of Decision: #REZ18002 Page 1 of 1 PLANNING AND ZONING COMMISSION FINDINGS OF FACT AND RECORD OF DECISION DATE OF DECISION: April 17, 2018 TYPE OF APPLICATION: Rezoning PROPERTY LOCATION: Section 12, Township 5, Range 82 PCLIN, NW ¼ of SE ¼ FILE NUMBER: #REZ18002 APPLICANT: Colorado World Resorts LLC This Record of Decision is made in accordance with the Avon Development Code (“Development Code”) §7.16.050(b): DECISION: Approval with the following findings: FINDINGS: 1. The Application was reviewed in accordance §7.16.050, Rezonings, Avon Development Code; 2. The application and supporting documentation provides sufficient information for PZC to determine that the application complies with the review criteria and Avon Comprehensive Plan; 3. The Application is substantially compliant with the purpose statements of the Development Code by providing for the orderly, efficient use of the Property, while at the same time conserving the value of the investments of owners of property in Town; and 4. The Planning and Zoning Commission held a public hearing on April 17, 2018, and considered all written reports, referral comments, and public testimony, prior to making a formal recommendation to the Town Council. 5. The RH, OLD, and STRO districts are found to be compatible with adjacent residential development and open space surrounding the property. THESE FINDINGS OF FACT AND RECORD OF DECISION ARE HEREBY APPROVED: BY:______________________________________ DATE: ___________________ PZC Chairperson 1 Avon Planning and Zoning Commission Meeting Minutes for April 17, 2018 Planning & Zoning Commission Meeting Minutes Tuesday, April 17, 2018 I. Call to Order The meeting was called to order at 5:00pm II. Roll Call All Commissioners were present. III. Additions & Amendments to the Agenda There were no changes to the published agenda. IV. Conflicts of Interest None. V. Landscaping Condition of Approval for Major Development Plan - Classroom Building Addition – PUBLIC HEARING File: MJR18003 Legal Description: Lot 5, 2A, and 2B Buck Creek Subdivision Applicant: Stephanie Lord-Johnson Summary: Landscaping requirements for the construction of a classroom building. Public Comment: None. Action: Commissioner Nusbaum motioned to approve the Landscape Plan with the following findings and conditions: Findings: 1. The landscape plan elements presented satisfy the code requirements and properly address the additions requested by the PZC. 2. Removal of condition 8, which states, “stairs on north side of building be curvilinear in one steady arch,” is acceptable due to the stairs’ use, location, and screening by landscaping. Condition: 1. All temporary irrigation systems shall be above ground and must be removed upon sufficient vegetation establishment, which shall not exceed one (1) year for ground cover, two (2) years for shrubs or three (3) years for trees. Commissioner Howell seconded the motion. The motion failed with a 4-2 vote; 2 in favor and four opposing. Commissioner Nusbaum made a motion to approve the Landscape Plan with an added condition to read “A biowswale will be added between the southwest corner of the lower parking area and the detention pond”. The motion was seconded by Commissioner Glaner. The revised motion passed with a 6-0 vote. VI. Major Development Plan and Alternative Equivalent Compliance Applications – PUBLIC HEARINGS 2 Avon Planning and Zoning Commission Meeting Minutes for April 17, 2018 A. 4254 Wildridge Road West File: MJR18001 and AEC18001 Legal Description: Lot 21A Block 3 Wildridge Applicant: Jeff Manley Summary: Proposal construct a new single-family house. This project requires an Alternative Equivalent Compliance application for the roof pitch under 4:12. Public Comment: Clyde Hanks letter was referenced – attachment D to staff’s materials. Action No. 1: Commissioner Barnes made a motion to approve the AEC application for Lot 21A, citing the following findings: 1. The proposed application was reviewed pursuant to §7.16.080(f), Development Plan; §7.16.090(f), Design Review, and §7.16.120 Alternative Equivalent Compliance; 2. The application is complete; 3. The application provides sufficient information to allow the PZC to determine that the application complies with the relevant review criteria; 4. Through the street-facing elements of the roof form, the AEC achieves the intent of the roof design standard to the same or better degree than the subject standard; 5. The AEC achieves the goals and policies of the Avon Comprehensive Plan to the same or better degree than the subject standard; 6. The AEC results in benefits to the community that are equivalent to compliance with the roof design standards; and 7. The AEC imposes no greater impacts on adjacent properties than would occur through compliance with the specific requirements of the Avon Development Code. Commissioner Glaner seconded the motion and the motion carried 5-1 vote. Action No. 2: Commissioner Barnes made a motion to approve the MJR18001 application for Lot 21A, citing the following findings and conditions: Findings: 1. The proposed application was reviewed pursuant to §7.16.080(f), Development Plan, §7.16.090(f), Design Review. The design meets the development and design standards established in the Avon Development Code; 2. The application is complete; 3. The application provides sufficient information to allow the PZC to determine that the application complies with the relevant review criteria; 4. The application complies with the goals and policies of the Avon Comprehensive Plan; 5. The demand for public services or infrastructure exceeding current capacity is mitigated by the application; and 6. The design relates the development to the character of the surrounding community. Conditions: 1. If an updated survey positively confirms encroachments, turf grass on the north edge of Lot 21A shall be removed and replaced with unirrigated native seed; and 2. Temporary irrigation systems must be removed upon sufficient vegetation establishment, which shall not exceed one (1) year for ground cover, two (2) years for shrubs or three (3) years for trees. 3 Avon Planning and Zoning Commission Meeting Minutes for April 17, 2018 Commissioner Glaner seconded the motion and the vote passed with a 5-1 vote; Golembiewski opposed. B. 4250 Wildridge Road West File: MJR18002 and AEC18002 Legal Description: Lot 21B Block 3 Wildridge Applicant: Jeff Manley Summary: Proposal to construct a new single-family house. This project requires an Alternative Equivalent Compliance application for the roof pitch under 4:12. Public Comments: None Action No. 1: Commissioner Barnes made a motion to continue the MJR18002 application for Lot 21B, pending revised roof pitch information. The motion was seconded by Commissioner Nusbaum. The motion passed unanimously with a 6-0 vote. Commissioner Barnes made a motion to continue the AEC18002 application for Lot 21B; motion seconded by Commissioner Nusbaum. The motion passed unanimously with a 6-0 vote. VII. Rezoning – Colorado World Resorts – PUBLIC HEARING File: REZ18002 Legal Description: Section 12, Township 5, Range 82 PCLIN, NW ¼ of SE ¼ Applicant: Colorado World Resorts, LLC Summary: Proposed rezoning to Residential High Density (with Short Term Rental Overlay) on the Highway 6 frontage, and Open Space, Landscaping, and Drainage (OLD) on the steep hillside above the buildable area. Public Comment: No comments. Action: Commissioner Barnes made a motion recommending approval of file REZ18002 to the Town Council citing the following findings: 1. The Application was reviewed in accordance §7.16.050, Rezonings, Avon Development Code; 2. The application and supporting documentation provides sufficient information for PZC to determine that the application complies with the review criteria and Avon Comprehensive Plan; 3. The Application is substantially compliant with the purpose statements of the Development Code by providing for the orderly, efficient use of the Property, while at the same time conserving the value of the investments of owners of property in Town; and 4. The Planning and Zoning Commission held a public hearing on April 17, 2018, and considered all written reports, referral comments, and public testimony, prior to making a formal recommendation to the Town Council. 5. The RH, OLD, and STRO districts are found to be compatible with adjacent residential development and open space surrounding the property. Commissioner Golembiewski seconded the motion and the recommendation carried with a 6-0 vote. VIII. Action on Records of Decision • MNR18005 – addition - 2869 O’Neal Spur Action: Commissioner Barnes made a motion to approve the Record of Decision for MNR18005. Commissioner Golembiewski seconded the motion and it passed 6-0 vote. 4 Avon Planning and Zoning Commission Meeting Minutes for April 17, 2018 • MNR18006 - Re-roof -2637 Bear Trap Action: Commissioner Barnes made a motion to approve the Record of Decision for MNR18006. Commissioner Howell seconded the motion and it passed 6-0 vote. • MJR18003 AEC18004 – Walking Mountains Classroom Building Action: Commissioner Barnes made a motion to approve the Record of Decision for MJR18005. AEC18004 Commissioner Nusbaum seconded the motion and it passed 6-0 vote. IX. Action on Meeting Minutes • April 3, 2018 PZC Minutes Action: Commissioner Howell made a motion to approve the Record of Decision for MNR18005. Commissioner Barnes seconded the motion and it passed 6-0 vote. X. Staff Updates • May 1st Meeting • Town Owned Properties Planning including Hahnewald Barn • PZC Appointments & Training XI. Adjourn The meeting was adjourned at 7:30pm. Approved this 1st Day of May 2018 SIGNED: ___________________________________________ Lindsay Hardy, Chairperson