Loading...
L9 B2 BMBC Duplex DesignTown of Avon Staff Report: Final Design Review September 19 Planning & Zoning Commission meeting Date 19 September, 1995 Legal Description Lot 9 ,Block 2, Benchmark Subdivision Project Type Duplex; new construction Zoning Residential Duplex (RD) Introduction This residential duplex will be located on a .25 acre site with a gentle (ten percent) north facing slope down and away from the road. Building materials include wood siding with stone accents and cedar shake shingles. The Commission reviewed the concept design at the September 5, 1995, and made generally favorable comments. The parking has been moved out of the 10 foot paving setback. A wider curb cut is proposed, with two surface parking spaces on the east side of the site. The buildings are in the same location proposed for the concept plan. Landscaped area has been increased. Design Review Considerations/Staff Comments According to the Commission's Procedures, Rules & Regulations, Section 6.10, the Commission shall consider the following items in reviewing the design of this project: 1. Conformance with the Zoning Code and other applicable regulations of the Town. • The proposed 34 foot building is within the 35 foot maximum height of the RD zone district • The 35% building lot coverage is within the 50 % maximum. • Fifty percent of the lot will be landscaped. Landscaping has been added in the front and back of the site. • The landscaping plan needs to include the key for all proposed trees, and the trees labeled "sp" should be clearly identified in the chart. • The driveway grade is less than three percent, and is within the maximum four percent grade between edge of pavement and property line. • Addresses and meter locations, and utility service lines are shown on the plan. • The building meets all setbacks and does not encroachment in any easements. a Snow storage area needs to be labeled. 0 Utility service lines need to be shown on the site plan. Lot 9, Block 2, Wildridge SuL ision, Final Design Review, page 2 September 19, 1995 Planning & Zoning Commission meeting Since the units are over 2,500 square feet, three parking spaces are required for each unit. These spaces are provided on the eastern side of the site. If the duplexes are subdivided, an easement will be needed to dedicate a parking space to the western unit. �. The suitability of the improvement, including type and quality of materials of which it is to be constructed and the site upon which it is to be located. The building site is small, which somewhat limits the design of the duplex. Although essentially a mirror image, the effect is minimized by slightly different garage door designs and roof lines. The building design includes a cedar shake roof and moss rock accents with wooden siding to be painted gateway gray with a Zeus trim. The materials are appropriate for the site and compatible with surrounding buildings. The compatibility of the design to minimize site impacts to adjacent properties. The building is located in the front of the lot in order to preserve the neighbor's views. The building design and materials are compatible with adjacent properties. 4. The compatibility of the proposed improvements with site topography The site is relatively level and the single -story building is compatible with a level site. 5. The visual appearance of any proposed improvement as viewed from adjacent aLld neighboring properties and public ways. The paved areas are landscaped and the building design is similar to others in the area. Although the 35 foot wide driveway is wider than is preferable, it is not out of character for the area. The landscaping and building materials present a pleasing view from Beaver Creek Boulevard. 6. The objective that no improvement be so similar or dissimilar to others in the vicinity that values, monetary or aesthetic will be impaired Though unique, the building conforms to the general development pattern of the area. It will not have a negative monetary or aesthetic impact on property in the vicinity. 7. The general conformance of the proposed improvements with the adopted Goals, Policies and Programs for the Town of Avon. The duplex conforms with the residential character of the area by the Comprehensive plan, and therefore conforms to the goal, policies, and programs for the Town. Staff Recommendation Staff recommends approval with the following conditions to be satisfied prior to submittal of building permit, Conditions of approval 1. The landscape chart be revised to include a key for the spruce tree. 2. A snow storage area be designated on the site plan. 9MBS. C Lot 9, Block 2, Wildridge Sup , ision, Final Design Review, page 3 September 19, 1995 Planning & Zoning Commission meeting 3. All utility service lines need to be shown on the plan. 4. A temporary pollution control plan be submitted. If you have any questions regarding this project or any planning matter, please call me at 949- 4280 (extension 131), or stop by the Community Development Department. Respectfully submitte , Kare nGriffith Town Planner 9B2BS.DOC Lot 9, Block 2, Wildridge SL _ tvision, Final Design Review, page 4 September 19, 1995 Planning & Zoning Commission meeting Planning & Zoning Commission Action ❑ Approved as submitted 3" Approved with conditions ❑ Denied ❑ Tabled ❑ Withdrawn by applicant Conditions (if applicable): 1. the landscape chart be revised to include a key for the spruce trees; 2. a snow storage area be designated on the site plan; 3. the applicant work with town engineer to relocate the entrance to the driveway further east to take advantage of larger turn around areas; 4. add six trees; 5. at the time of construction the applicant will put paint samples on the bldg. wi W the actu bldg, material and will be reviewed by Planning and Zoning Comm. Signed:4� " i and approved. Date Q 5 Jack Hunn, Attest: Date Sue Railton, Secretary 9B2BS.DOC