Loading...
PZC Packet 110601Town of Avon Planning & Zoning Commission Site Tour November 6, 2001 12:00 PM Town of Avon Municipal Building 400 Benchmark Road Meet in the Community Development Conference Room. Lunch is available to those Commissioners who RSVP by 10:00 a.m. I. SITE TOUR Posted on November 2, 2001 at the following public places within the Town of Avon: • Avon Municipal Building, main lobby • Avon Recreation Center, main lobby • Alpine Bank, main lobby • City Market, main lobby • On the Internet at http: / /www.avon.org Town of Avon Planning & Zoning Commission Work Session November 6, 2001 5:30 PM Council Chambers Town of Avon Municipal Building 400 Benchmark Road I. AGENDA Discussion of regular meeting agenda items. Posted on November 2, 2001 at the following public places within the Town of Avon: • Avon Municipal Building, main lobby • Avon Recreation Center, main lobby • Alpine Bank, main lobby • City Market, main lobby • On the Internet at http: / /www.avon.org Town of Avon Planning & Zoning Commission Regular Meeting November 6, 2001 9 1AW Council Chambers Town of Avon Municipal Building 400 Benchmark Road AGENDA I. Call to Order II. Roll Call III. Additions and Amendments to the Agenda IV. Conflicts of Interest V. Consent Agenda Approval of the October 16, 2001 Planning & Zoning Commission Meeting Minutes [Tab 11 VI. Design Review A. Lot 28, Block 3, Wildridge Subdivision [Tab 2] Project Type: Fence Application Applicant /Owner: Marjorie Marks Address: 4491 Wildridge Road West Posted on November 2, 2001 at the following public places within the Town of Avon: • Avon Municipal Building, main lobby • Avon Recreation Center, main lobby • Alpine Bank, main lobby • City Market, main lobby • On the Internet at http: / /www.avon.org Town of Avon Planning & Zoning Commission Regular Meeting November 6, 2001 6:00 PM Council Chambers Town of Avon Municipal Building 400 Benchmark Road AGENDA I. Call to Order 11. Roll Call III. Additions and Amendments to the Agenda IV. Conflicts of Interest V. Consent Agenda Approval of the October 16, 2001 Planning & Zoning Commission Meeting Minutes [Tab 1] .. VI. Design Review A. Lot 28, Block 3, Wildridge Subdivision [Tab 2] Project Type: Fence Application Applicant /Owner: Marjorie Marks Address: 4491 Wildridge Road West Posted on November 2, 2001 at the following public places within the Town of Avon: • Avon Municipal Building, main lobby • Avon Recreation Center, main lobby • Alpine Bank, main lobby • City Market, main lobby VII. OTHER BUSINESS A. Resolution No. 01 -19 [Tab 3] Design Guidelines B. Resolution No. 01 -20 [Tab 4] Town Center Plan C. Approval Conditions Memo [Tab 5] D. Staff Approvals: 1. Lot 67, Block 3, Wildridge Subdivision 4243 Wildridge Road West Shingle replacement 2. Lot C, Avon Center at Beaver Creek [Tab 6] Sheraton's Mountain Vista 160 West Beaver Creek Boulevard Entry truss E. Sign Permits 1. Lot 62/63, Block 2, Benchmark at Beaver Creek 137 Benchmark Road Vail /Beaver Creek Travel VIII. ADJOURN Posted on November 2, 2001 at the following public places within the Town of Avon: • Avon Municipal Building, main lobby • Avon Recreation Center, main lobby • Alpine Bank, main lobby • City Market, main lobby • On the Internet at http: / /www.avon.org Town of Avon Final Design Staff Report November 6, 2001 Planning & Zoning Commission meeting Report Date November 1, 2001 Project Type Fence Application Legal Description Lot 28, Block 3, Wildridge Sul)division Zoning DILIplex — PUD Address 4491 Wildridge Road West Introduction The applicant is requesting the approval of a split rail fence along the driveway. The fence proposed is a two-tier split rail fence. Attached you Avill find an outline and pictLires of the fence. Design Review Considerations According to the Commission's Procedures. Rules & Regulations, Section 4.10, the Commission shall consider the following items in reviewving the design of this project: 1. The conformance with setbacks, massing, access, land use and other provisions of the Zoning Code. • 1411oived use: Conforms to the allovved residential Use. • Lot Coverage: Tile split rail Fence does not impact the lot coverage. * Scthacks: The split rail fence will begin at the property line, which wvill encroach into the front snow storage and drainage easement. • Building Height: The applicant's request is consistent Nvith the Division of Wildlife recommendations tliat Fences should not exceed 48" in height. 0 Lamlscaping: The knee will be visible frorn the road and is intended as a VISUal barrier along the (Iriw ev. ay and street. 2. The type and quality of materials of NN'hich the structure is to be constructed. I , lie split rail fence is consistent -with the TOWII'S N�lUil-C111CIAS 601- lllatCrialS. 3. The appearance of proposed improvements as vieived f•orn adjacent and neighboring properties and public iNaNs, wi:itli respect to architectural style, massing, height, orientation to street, quality of materials, and colors. 'I lie split rail fence as designed, is intended as delineation ofthe drivewvay. 4. The of) Jective that no improvement be so similar or dissimilar to others in the w °icinity that monetary or aesthetic values NN ill be impaired. The fenced area as proposed, appears to he consistent wN Ith other fences In the area for the same purpose. As proposed, the t-cilce will not impair 111011ctarw° or aesthetic w blues. Tow) of Avon Community Development 7 (E r7 .4 I , ., I Fax 0470) 4T. Lot 2-8, Block 3,'i 7 ildrid,-,le Subdivision, Fence Application November 6, 2001 I'lanninu & Zoning Con-u►ission Meeting, Pace 2 ot'2 15. 'I'lie general conformance of the proposed improvements NVrith the adopted Goals, Policies and Programs for the Town of Avon. This tcue conforms with the adopted Goals, Policies and Pro(grams of the To\vn. Staff Recommendation Staff recommends approval of the fence application for Lot 28, Block 3, \Vildridge Subdivision. If Nrou have any qUeStiOlIS regarding this project or any, planning matter, please do not hesitate to call me at 748.4413 or stop by the Community Development Department. i Respectfully SLI 1111t)e d Eric Johnsor ,',,, ToWn of Avon Community Development 1:-)70) 748 4,,)'i( 7 U) 949 - 57 � . \ _ . » ' . / ~-T ' `� ' > / ' ' / ` � / � ` / / . . ,-. � N. ,�� � 'r �. :x r +� �; , �. d �+' TOWN OF AVON PLANNING & ZONING COMMISSION RESOLUTION NO. 01-19 SERIES OF 2001 A RESOLUTION APPROVING THE TOWN OF AVON RESIDENTIAL, COMMERCIAL AND INDUSTRIAL DESIGN GUIDELINES - PROCEDURES, RULES AND REGULATIONS WHEREAS, Section 2.16.070 of The Avon Municipal Code establishes the Planning and Zoning Commission for purposes of design review of the exterior design of all new structures and property development and additions to all existing structures and property development; and WHEREAS, Chapter 2.16 of The Avon Municipal Code grants authority to the Planning and Zoning Commission to enact `Design Review Guidelines' and specifically states: The objectives of the design review function of the Planning and Zoning Commission shall be as follows: a. To prevent excessive or unsightly grading of property which could cause disruption of natural watercourses or scar natural landforms; b. To ensure that the location and configuration of structures, including signs and signage, are visually harmonious with their sites and with surrounding sites and structure and that there shall be conformance to the Master Plan of the Town; c. To ensure that the architectural design of structures and their materials and colors are visually harmonious with the Town's overall appearance, with surrounding development, with natural and existing landforms, and with officially approved development plans, if any, for the areas in which the structures are proposed to be located; and WHEREAS, the Planning and Zoning Commission have reviewed the attached Town of Avon Residential, Commercial and Industrial Design Review Guidelines - Procedures, E Planning & Zoning Commission \Resolutions \2001 Resolutions \01 -19 DRG Adoption.doc Rules and Regulations (Exhibit A), as prepared and revised by Community Development staff, NOW, THEREFORE, BE IT RESOLVED, that the Planning and Zoning Commission hereby recommends to the Town Council the approval of these Town of Avon Residential, Commercial and Industrial Guidelines - Procedures, Rules and Regulations (Exhibit A) in order to replace and amend the existing Planning and Zoning Commission Procedures, Rules and Regulations as adopted January 27, 1998. ADOPTED THIS 6th DAY OF NOVEMBER, 2001 Signed: Date: Chris Evans, Chair Attest: Date: Paul Klein, Secretary FAPlanning & Zoning Comm ission\Resolutions\2001 Resolutions \01 -19 DRG Adoption.doc TOWN OF AVON PLANNING & ZONING COMMISSION RESOLUTION NO. 01 -20 SERIES OF 2001 A RESOLUTION APPROVING THE AVON TOWN CENTER PLAN AS A POLICY AND GUIDANCE MASTER PLANNING DOCUMENT FOR THE TOWN OF AVON WHEREAS, The Town of Avon recognized the potential for new development and redevelopment of an area of town known as the "Town Center" and developed basic concepts to guide development of this area in a phased approach; and WHEREAS, the Town of Avon prepared a conceptual development plan for the Town Center with the understanding that as property owners prepare to invest in development of this area the Town recognizes the benefit of a coordinated plan to best reinforce the sense of a cohesive Town Center focused on a redeveloped town pedestrian mall; and WHEREAS, the Planning and Zoning Commission have reviewed the attached Avon Town Center Implementation Plan (Exhibit A) as prepared and revised by RNL Design and Town Staff and the Town has held several public meetings to discuss the development of the Avon Town Center Implementation Plan; NOW, THEREFORE, BE IT RESOLVED, that the Planning and Zoning Commission hereby recommends to the Town Council the adoption of the Avon Town Center Implementation Plan (Exhibit A) in order to serve as a policy and guidance Master Plan for the beneficial coordinated development of this area known as the Town Center. ADOPTED THIS 6th DAY OF NOVEMBER, 2001 Signed: Date: Chris Evans, Chair Attest: Date: Paul Klein, Secretary F: \Planning & Zoning Commission \Resolutions \2001 Resolutions \01 -20 TownCenterPlan.doc d T Pi R� t7mrnO � o z ernTl o 0 m z n m 0 1 -u N _p I � d o 0 O N C-) n r z m 0 w rn s Il_ 1 C) -p Cl m aD x o 00 � m0 C Z m C13 M m m O 7C C co Z C7 —1 Z Z n a cn M rn N O h00 /D00 e +,.6nn n -6n n/ -n s> -4 o0 m• �$ LA - A n rn z� v �opD� CD n m rOn � m ti n 0 z az I Cn m 0 a z _ a O N x maw — � 100 C O D O � � Q �rn z 3HIU3311.)H' ZO CSiiZ69COC Xdd 99:Gt tnn�irn��� jadjeH W uwo e;7n:ni in Pn AOkl Nov 02 01 10:02a T - a �y Li I C O Y*1 � � O m � O m z n M 0 0 a O V / Cal I Cn N 0 U') n A r- m 9 d V J �m n� A m o C z rn m O f- CD r v —I n D C) C.) O � m � N O John M Harper �m Z3 II � 0 0 C7 A) 0 CO VJ C Q CD m CD d n r 970 949 9944 p.6 -� D I 00 O D Z CO m O pp M � C7 �C7 � m Z D --1 U) --q n M d r� Z C-) Z m M D M Lf) m --i O p D 0 n � = D D u D C) D 0 � C rrl Z U) r n 0 C O o -- C7 A D> D D m \ 0 r r ri -� r P W I K 0 r -� D I 00 O D Z CO m O pp M � C7 �C7 � m Z D --1 U) --q n M d r� Z C-) Z m M D M Lf) m --i O p D 0 n � = D D u D C) D 0 � C rrl Z U) r n 0 C O o -- C7 A D> D D m \ 0 r r ri -� r P W I K 0 Nov 02 01 10:02a John M Harper a a T o�v-o moCD 0 Fin m z m v I 0 CM cn � I � o d 0 o G] A • r Z � d D co z o a r w C/) m0 M Q > m O C z T11 m Om ; r�% c r Z O Z 0 rl LL � s i c�Q 3 m r s�4 970 949 9944 p.7 m Rid C O L O R A D O TowN of AvoN RESIDENTIAL, COMMERCIAL, AND INDUSTRIAL DESIGN REVIEW GUIDELINES PROCEDURES, RULES, AND REGULATIONS ADOPTED NOVEMBER 6, 2001 Table of Contents Sections 1/ Purpose and Intent Page 3 2/ Authority Page 4 3/ Definitions and Engineering Standards Page 5 -9 4/ Residential Development Guidelines A. Site Development 1 Page -15 B. Building Design Page 16 6 -18 C. Landscaping Page 19 -21 D. Miscellaneous Items Page 22 -23 5/ Commercial and Industrial Development Guidelines A. Site Development Page 24 -30 B. Building Design Page 31 -36 C. Landscaping Page 37 -39 D. Miscellaneous Items Page 40 -41 6/ Application Requirements and Processing Page 42 -43 7/ Planning and Zoning Commission Review Page 44 -46 8/ Miscellaneous Regulations Page 47 Appendices 1. Recommended Plant List Page 48 -50 2. Town of Avon Noxious Weeds Page 51 3. Sketch Design Plan/Final Design Plan Application & Checklist Page 52 -55 4. Pollution Control Plan Page 56 -59 5. Stormwater Control Plan Page 60 -66 6. Example Color Board Page 67 -68 7. Example Site Plan Page 69 8. Fee Schedule Page 70 Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 2 Adopted November 6, 2001 1. Purpose and Intent Design Philosophy The general design philosophy for the Town of Avon is to preserve and protect property values by creating an aesthetic quality throughout the built environment of our community. The Town should continue to be perceived as a contemporary mountain town, complementary to the natural landscape and unbuilt environs. The Town should appear as a cohesive unit comprised of simple building forms, subdued colors, and predominantly pitched roofs. In residential areas, the relationship between buildings and the natural environment should be harmonized rather than dominating. Landscaping should blend the surrounding natural environment and the home, not hide one from the other. Form, scale, proportion, and materials should support the natural environs and reinforce those characteristics that uniquely identify a neighborhood's built environ as it relates to the Town. Typical Wildridge Vista : From Wildridge Road East Looking South towards Beaver (.reek. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 3 Adopted November 6, 2001 2. Authority The authority to enact `Design Review Guidelines' is granted by Chapter 2.16 of The Avon Municipal Code, which specifically states: C. The objectives of the design- review function of the Planning and Zoning Commission shall be as follows: a. To prevent excessive or unsightly grading of property which could cause disruption of natural watercourses or scar natural landforms; b. To ensure that the location and configuration of structures, including signs and signage, are visually harmonious with their sites and with surrounding sites and structure and that there shall be conformance to the master plan of the town; c. To ensure that the architectural design of structures and their materials and colors are visually harmonious with the town's overall appearance, with surrounding development, with natural and existing landforms, and with officially approved development plans, if any, for the areas in which the structures are proposed to be located; d. To ensure that plans for the landscaping of property and open spaces conform with the rules and regulations as prescribed by the Town and by this chapter and to provide visually pleasing settings for structures on the same site and on adjoining and nearby sites (Ord. 83 -11). Purpose and Intent To establish procedures, riles, and regulations by which the Commission shall receive, review, and rule on applications for the design of any proposed alterations to real property, including land and any improvements on that land, within the Town of Avon. Scope The scope of these procedures for design review includes but is not limited to site grading, excavation or fill; the location and configuration of structures on a site; the architectural design of structures including color and materials; landscaping of sites including number, size, placement, species of plantings and provisions for maintenance systems of same. The Commission shall review and act upon the general design and appearance of any building, construction, paving, grading, or landscaping proposed on any lot or parcel of land within the Town, including municipal and other government projects. It shall be unlawful to begin any such work prior to approval by the Commission. Compatibility These Rules of Procedure are in accordance with Section 2.16.070 of the Avon Municipal Code, and details the procedures for approval of development plans required by Section 17.12.020 of the Avon Municipal Code. These Rules are intended to complement other ordinances of the Town, and shall neither duplicate nor supersede them. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 4 Adopted November 6, 2001 3. Definitions and Engineering Standards Access: The place, means, or way by which pedestrians and vehicles shall have adequate and usable ingress and egress to property, use, orparking space. Accessory Structures: An accessory structure (`building' or `use') means a subordinate building or use which located on the same lot on which the main building or use is situated and which is reasonably necessary and incidental to the conduct of the primary use of such building or main use. Access Grade: The slope of a road, street, driveway, or other means of access, as measured from the back side of pan along the centerline of the means of access. Annual High Water Mark: The visible line on the edge or a river, stream, lake, pond, spring or seep up to which the presence and action of water are so usual and long conditions (with a recurrence interval of one (1) year or less) so as to create a distinct character with respect to vegetation and the nature of the soil. Applicant: An owner or owner's representative who is authorized to represent and/or act upon any application or submittal. Architect: An architect licensed in the State of Colorado. Architectural Projection: When an architectural projection (i.e. roof eave, cupola) physically projects beyond the plane of a required limitation (i.e. height). Best Management Practice (BMP): A structural device designed to temporarily or permanently store or treat stormwater runoff in order to mitigate flooding, reduce pollution, and provide other amenities. BMP's include wet ponds, created wetlands, filters, and infiltration trenches and galleries. Berm: A mound of earth used to screen or separate one area from another to reduce visual, noise and similar impacts of development. Berm may also mean the act of pushing earth into a mound. Building Code: In the Town of Avon, the most recently adopted version of the Building Code shall apply. Building Envelopes: That portion of a lot within which all buildings are confined. A specified area that does not alter or otherwise affect existing setbacks or easements. Building Height: The distance measured vertically from the existing grade or finished grade (whichever is more restrictive) at any given point to the top of a flat or mansard roof or the highest ridgeline of a sloping roof. (Ord 91 -10 part 1). pro oseA goo C �rade /Utisfiin9 -79t Building Height is always measured from the most restrictive grade, either existing or proposed (finished) grade. All elevations must be labeled in numeric form. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 5 Adopted November 6, 2001 -'"- - 6 P. t'rm 810', _E 5KIN I, 6mc 8100 Building Setbacks: A line or location within a lot or site which establishes the permitted location of uses, structures, or buildings on a lot. Construction (Activity): Work done on a job site that produces an altered or new structure. Includes excavation, assembly, and erection of components. Construction Staging Plan: A site plan submitted with final design plans showing, at the minimum: contractor parking, construction materials storage, limits of site disturbance, snow storage, refuse storage, sanitation facilities, project signage, and construction trailer(s) location, as applicable. Development: A form of activity that requires some form of permit or other approval pursuant to these regulations, including: 1/ The building of a new residential, commercial, or industrial structure, 2/ The alteration or modification of an existing residential, commercial, or industrial structure, 3/ Grading or excavation activity that is intended to prepare a construction site. Drainage (System): A built system of pipes, channels, or trenches, or finished grades utilized to convey waste water or water borne waste in a collective and organized method. Driveway: A paved all- weather driving surface on private property which provides access to dwelling units. Duplex: A detached building containing two dwelling units, designed for or used as a dwelling exclusively by two families, each living as an independent housekeeping unit. Dwelling Unit: Any building or portion thereof for residential purposes, including single- family, two - family, duplex, multifamily dwellings, but not including hotel, motel, or lodge (accommodation) units. Easements: A conveyance or reservation of an incident of ownership in real property for one or more specific purposes, public or private. Exterior Storage: Storage outside of a building or dwelling unit. Exterior Walls: The outer wall surfaces of a building, structure, or dwelling unit. Fences: Enclosing framework for exterior areas, such as yards or gardens. Final Design Plan: A hard -line plan which meets the requirements indicated in Appendix 3. Frontage: The portion of a lot that fronts on a public or private street. Fireplace: Opening at the base of a chimney in which combustible material, such as wood or gas, can be safely burned to produce heat. Specific designations of fireplaces by type are as defined in Chapter 15.40 of the Town of Avon Municipal Code. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 6 Adopted November 6, 2001 Grade (existing): The existing or natural topography of a site prior to construction. Grade (finished): The grade upon completion of a construction project. Gross Floor Area: The total surface floor areas of a structure, including habitable and non - habitable areas unless specifically noted. Hard Line Drawing: An architectural or engineering drawing produced by the use of computer aided graphics, or other mechanical implement, which does not represent free -hand drawing. Landscape Area: The area of a site not covered by buildings, driveways, and covered walkways. Areas such as water features and other similar features appurtenant to natural landscape areas shall also be considered part of the landscaping area. Lot or Site: A parcel of land occupied or intended to be occupied by a use, building, or structure under the provisions of Title 17, Zoning Regulations, and meeting the minimum requirements of Title 16, Subdivision Regulations. A lot or site may consist of a single lot of record, a portion of a lot record, a combination of lots of record or portions thereof, or a parcel of and described by metes and bounds. Minor Project /Minor Modification: Certain forms of exterior development and improvement that are exempted from the public review process by the Director of Community Development. Multifamily Residence: A building containing three (3) or more dwelling units, not including hotels or lodges, but including townhouses, condominiums and apartments with accessory use facilities limited to an office, laundry, recreation facilities and off - street parking used by the occupants. Owner /Owner Representative: The owner of title to a property, or his /her designated appointee and representative for an application. Designation of a representative must be made in writing as part of any application. P.E. Stamped Design: A design that is stamped, signed, and date by a Colorado registered professional engineer. Planning and Zoning Commission: A commission established in the Avon Municipal Code 2.16.010, to operate in accordance with its own rules of procedure as provided for in Section 11.2 of the Town Charter. Retaining Wall: A wall designed to maintain differences in ground elevations by holding back a bank of material. Setback: The distance from a lot or site line, creek or stream measured horizontally to a line or location within the lot or site, which established the permitted location of uses, structures, or buildings on the site. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 7 Adopted November 6, 2001 Sketch Plan: The first formal application for design review. Sketch plan must be approved prior to applying for final design review, and after a pre- application meeting has been held with Community Development staff, an comply with requirements indicated in Appendix 3. Single Family Residence: A residence building.containing not more than one dwelling unit occupied exclusively by one family as an independent housekeeping unit. Site Coverage: The ratio of the total building and disturbed area on a site to the total area of a site, expressed as a percentage. Site Plan: A drawing that shows, at a minimum, property lines of a building lot, elevation information, compass direction, length and scale of property information, and the locations of structures to be built on the lot. See example site plan in Appendix 7. Snow Storage Area: An area equal to twenty percent (20 %) of impermeable surfaced area upon which aboveground construction does not occur shall be designated as a `snow- storage area' and not developed in a manner inconsistent with such use. Landscaping shall not be considered inconsistent with such use. Any designated snow storage area shall be not less than six feet (6') wide, shall be adjacent to the impermeable area from which the snow is to be removed, shall not be included in any parking area required by the minimum parking requirements, and shall be contained in such a manner that runoff is directed though a treatment facility (when required). See 17.50.100 `Snow Storage' of Avon Municipal Code for additional design requirements. Slope: Shall be established by measuring the maximum number of feet in elevation gained or lost over each ten feet (10') or fraction thereof measured horizontally in any direction between opposing lot lines. The relationship of elevation or vertical measure as divided by the horizontal measurement shall be expressed as a percentage as a means of quantifying the term "slope ". Staff: Town of Avon Community Development employees. Staff Approval: Approval on a minor project that is reviewed and issued by Staff, without public hearing. Survey: A land plat survey, stamped and signed by a registered Colorado Surveyor, showing contour intervals at engineering scale of 1 " =10'. No survey will be accepted that is older than 3 years from the receipt date of design review submittal. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 8 Adopted November 6, 2001 Table 1.0: Residential Access, Parking, and Engineering Standards Standard Single Family Duplex Multi Family Other: Driveway Min: 14 feet Min: 14 feet Min: 20 Over Duplex upon Curb cut Max: 18 feet Max: 18 feet Max: 24 review by Town Engineer Driveway 4% maximum for 4% maximum 4% maximum for Heated area may Grades first 20' adjacent for first 20' first 20' adjacent not encroach and adjacent and and perpendicular beyond property perpendicular to perpendicular to public way/ 4% line. public way/ 4% to public way/ maximum for first maximum for 4% maximum 20' adjacent to first 20' adjacent for first 20' garage/ 8% to garage / 10% adjacent to Maximum Maximum garage / 10% Maximum Permitted 1 Permitted 1 Permitted 1 Permitted (6 Additional points Curb Cuts DU's and under) of access must be approved specifically Parking 2 spaces per 2 spaces per Studio: 1 space See Zoning Code Requirements unit/ 3 spaces unit/ 3 spaces 1 Bedroom: 1.5 for specific per units over per units over spaces requirements 2,500 sq. ft (not 2,500 sq. ft (not All others: 2 (section inc. garage) inc. garage) 17.24.020) spaces Parking Stall 9'x 18' minimum 9'x 18' 9'x 18' minimum / See Zoning Code Size / 7.5' vertical minimum / 7.5' 7.5' vertical for specific Minimums clearance / 90 vertical clearance / 90 requirements degree parking clearance / 90 degree parking (section degree parking 17.24.020) & guest parking requirements Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 9 Adopted November 6, 2001 4. Residential Development Guidelines General Design Compatibility All design shall be compatible with existing built structures, the immediate unbuilt environment, and the design philosophy of the Town. It should not be inferred from these guidelines that all buildings are expected to have similar design. The overall objective of these guidelines is allow flexibility so that individual building sites can directly respond to the topography and unique features of the natural unbuilt environment. Buildings should be treated as an integral part of the site, rather than separate objects at odds with their surroundings. However, compatibility should be achieved through the use and proper consideration of the guideline criteria contained herein. On the Eagle River at Eaglebend, Filing No. 1. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 10 Adopted November 6, 2001 A. Residential Site Development Site design Site design and layout is critical to appropriate architectural development of a structure and its supporting improvements to the property. Buildings should blend in with natural settings, be stepped in appearance where practical, and be limited in the need for extensive site grading and slope retention. Buildings should be compatible with the site, and not appear to intrude or project from a lot with no relation to the surrounding landforms. Requirements: 1. Site layout and proposed improvements shall consider the use of passive and active solar use. 2. The location of structures and access shall complement the existing topography of the site. Excessive grading and/or the use of engineer - designed retaining walls is discouraged when an alternate site layout would minimize such disturbances. 3. Removal of vegetation, trees, and other significant landforms on a site will be limited and not extend beyond a demarcated site disturbance area identified on submitted plans. The identification and removal of noxious non - native vegetation and replacement with native vegetation shall be encouraged on properties regardless of where they exist on site (ie. outside site disturbance area). 4. All disturbed areas should be revegetated with recommended plant species listed in Appendix 1. The use of listed noxious weeds, as provided in Appendix 2, is prohibited. 5. Where no development has been identified, construction shall at a minimum avoid: all drainage and utility easements, development setbacks, areas over 30% in slope, and unique and sensitive natural site features. 6. Buildings on sloping lots shall be designed to step with the existing (natural) grades. Site Access Access to the building site requires consideration of topography and building orientation. Avoidance of steep slopes, the blending of access with the natural contours of a site, and sensitivity to solar orientation, are important in establishing a successful access. Where access drives connect to public streets, drainage and landscape maintenance are the responsibility of the owner. Additionally, heated driveways must not exceed the property line. Requirements: 1. Adequate distance from intersections and proper relation to other entrances. 2. Satisfactory width, grades, radii etc. as indicated in Table 1.0. 3. Turn lanes, if required by the Town Engineer, shall be designed in accordance with requirements indicated in Table 1.0. 4. Residential projects with 6 or fewer units shall be restricted to a single point of vehicle access from the public right -of -way. Additional points of access must be specifically approved by the Planning & Zoning Commission, with the finding that additional access points are required for the project to otherwise conform to these Design Standards and other applicable Town regulations. 5. The grade of the first 20 feet of driveway adjacent and perpendicular to the paved public way shall not exceed 4% grade. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 11 Adopted November 6, 2001 6. Parking lot grades should not exceed 6% and driveway grades should not exceed 8% for multi - family residential and commercial projects or 10% for small residential projects. 7. The grade of the first 20 feet of driveway adjacent to the garage or outside parking space shall not exceed 4% grade. 8. Project site plans shall include provisions for emergency vehicle access when required by Code or local emergency service provider. 9. Adequate maneuvering for vehicles on site must be provided. Parking and Loadinli Parking and loading location and design is significant in avoiding conflict in multi - family projects, and avoiding the potential of regular on- street parking in all neighborhoods. The intent of parking and loading design on site is to provide residents and guests suitable parking locations that are also durable and functional. Requirements: 1. Required spaces provided must be in compliance with standards set forth in the `Access, Parking, and Engineering Standards' Table 1.0. 2. All spaces must be accessible and meet minimum size requirements as outlined in the `Access, Parking, and Engineering Standards' Table 1.0. 3. Residential loading spaces properly located to function with improvements and accessible to delivery vehicles without restricting street traffic or on -site circulation. 4. Pavement design must be compatible with proposed use. All parking surfaces shall be asphalt, concrete, concrete pavers, or another impervious surface. Gravel is not an acceptable material. Easements Disturbance in drainage and utility easements should be avoided. Landscaping placed in easements may be subject to removal and are the responsibility of the property owner to replace and maintain. Trees placed in drainage easements paralleling public streets may be damaged or destroyed by Town maintenance operations. Requirements: 1. Dedicated easements shall remain unobstructed unless they are officially vacated. 2. Landscaping improvements shall avoid placement in easements whenever possible. Any landscaping improvements placed in easements shall be the responsibility of the property owner to maintain and replace should they be damaged or destroyed by the Town while doing drainage, snowplowing, or utility work. Site Grading Grading a property should be minimized, and only done as necessary for building improvement. Grading required in easements and setbacks is expected to be restored and revegetated to natural conditions before site construction is complete. Where finished grades require retaining wall placement, a series of lower retaining walls with landscaped terraces is preferable to a high wall with an unbroken vertical face. Requirements: 1. Site improvements should be designed to conform with existing site topography to minimize required grading and effect on adjacent properties. All grading shall occur within the property boundaries. Both existing and finished grades are required to be clearly Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 12 Adopted November 6, 2001 marked on the site plan submittal, to the extent specified on the Minimum Submittal Requirements (Appendix 3) checklist. 2. Maximum slope of disturbed slopes shall not exceed 2 feet horizontal to 1 foot vertical without special documentation and review. 3. Horizontal and vertical variations in grading cut and fill areas should resemble a natural configuration. Long slopes should be varied to avoid the appearance of flat surfaces, unless the original slope was in this configuration prior to grading. 4. Building siting and foundation excavation shall avoid the disruption of existing natural features such as mature trees whenever possible. 5. All grading, including utility connection, is required to be shown within the proposed `site disturbance boundary' on submitted application plan sets. 6. All grading shall require erosion control methods so that dirt and fill material does not leave the property on to the public right of way and adjacent properties. A surety may be required for the proper installation and maintenance of erosion control. 7. All graded areas shall be revegetated as soon as practicable during the construction process. Dust suppression and the prevention of noxious weed infestation is the responsibility of the developer. A well -sited home requires less extensive grading and creates a more natural `stepped' appearance on a slope, such as this home at Eaglebend, Filing 1. Drainage Adequate grading plans ensure that drainage is functional on a building site. Drainage easements must remain substantially unobstructed to accommodate drainage from a building site. Grading plans must adequately demonstrate positive drainage away from building structures. Requirements: 1. All drainage easements shall remain unobstructed. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 13 Adopted November 6, 2001 2. All structures shall be located above or be protected from the 100 -year floodplain, where identified by FEMA mapping. Where mapping is unavailable, the Town may require a qualified engineer to conduct an analysis of whether or not the proposed structures are proposed in a floodway or floodplain. 3. Minimum setback of thirty feet shall be maintained from mean annual high water mark of all continuously flowing streams. 4. All development shall conform to the Town of Avon Drainage _Design Manual, as part of the Master Drainage Study (Sept. 1994 /Appendix 5). 5. All construction projects shall conform to the Town of Avon Pollution Control Plan Manual. (Appendix 4). Snow Removal and Storage The Town of Avon receives varying amounts of precipitation depending on aspect and elevation, typically in the form of snow. However, all sites must be able to adequately accommodate and transport snow on site and in conjunction with approved drainage easements. Requirements: 1. An area equal to 20% of the total impermeable surfaced area of the site, upon which aboveground construction does not occur, shall be designated and developed as a snow storage area. 2. Designated snow storage areas shall be located and developed to be compatible with snow removal operations, not less than six (6') feet wide, and shall be adjacent to the impermeable area from which the snow is to be removed. 3. Runoff from snow storage areas shall be directed through a treatment facility as required for treatment of runoff from parking and driveway areas. 4. On -site snow storage requirements may be waived by the Planning and Zoning Commission upon the demonstration that an appropriate alternative snow - storage site is available and that arrangements have been made for the continuation of snow removal and off -site storage. 5. Excavation, retaining walls, or other structures within slope maintenance and snow storage easements adjacent to public rights -of -way shall be confined to those strictly required for effective site access. Water and Sewer, Trash Storage Each site design shall address the availability and design of water and sewer service, along with trash storage on the lot. Trash storage must be identified on the site plan, including design detail, for all multi- family units greater than a duplex. Requirements: 1. Each structure designed for human occupancy shall be connected with water and sewer facilities made available by existing water and sewer districts. Letters of commitment from the appropriate districts may be required. 2. No private wells or sewer systems shall be used within the Town except as provided in the Subdivision Regulations. 3. Each project shall have receptacles for the temporary storage and collection of refuse. The handling of trash for all projects larger than a duplex (ie. triplex) shall be noted on the site plan. When necessary, bear resistant trash receptacles may be required. 4. All trash receptacles shall be screened from public view and protected from disturbance. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 14 Adopted November 6, 2001 5. Refuse storage area shall be accessible by collection vehicles and should be incorporated into building design whenever possible. Non combustible receptacles only for ash. Sidewalks As necessary in certain subdivisions and planned unit developments, the inclusion of sidewalks on a property may be required by the Town to provide a neighborhood amenity. Requirements: 1. Sidewalks or walkways should be provided as necessary for efficient pedestrian circulation within the project and with neighboring properties. Walkways should be separated from vehicular traffic where possible. 2. Walkways should be constructed of attractive, durable materials such as decorative concrete or brick pavers. 3. Walkway widths should be compatible with anticipated uses, but in no instance, shall be less than 4' wide as a minimum standard. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 15 Adopted November 6, 2001 B. Residential Buildina Desian General Design Character In addition to the stated Design Philosophy, and General Design Compatibility, a residential building must conform to setback, building area ratios, and height limitations of the applicable zone district. Buildings should be oriented to take advantage of solar gain and view corridors, where possible. Additionally, building design and location should generally minimize impacts on solar and view corridors of neighboring properties. It is preferred that residential buildings be designed as a composition of mass elements rather than larger single `blocks' that appear unrelated in form and context. Building Height The height of structures, unless otherwise specified in a planned unit development, shall conform to the zone district limitations stated in Title 17: Zoning Regulations. The definition of height is set forth in the `Definitions' section of these guidelines. No exceptions to the height requirements shall be made, except for penetrations that add architectural variety such as flues, chimneys, cupolas, etc. A". , MC�4f1$frD FPo� �� . - MORP RVWCTWO Gw.U-_ -' 8Inti Building Height will be determined by utilizing the site development plan and elevations. All ridge elevations, and numeric existing and proposed grades must be labeled on the site plan to accurately determine height. Additionally, the elevation plans must show existing and proposed grades (also labeled in numeric form), such as the illustration above. Building Materials and Colors The intent of these guidelines is to provide architectural control to ensure that the architectural design of structures and their materials and colors are visually harmonious with the town's overall appearance, with surrounding development, with natural and existing landforms, and with officially approved development plans. These guidelines should represent the minimum standard to achieve this goal, without being so cumbersome as to not allow varied high - quality design that meets this intent. Requirements: 1. The use of high quality, durable building materials is highly encouraged. 2. The following materials and wall finishes will not ordinarily be permitted on the exterior of any structure: asphalt siding, imitation brick, asbestos cement shingles or siding, imitation log siding or plastic. Metal siding, concrete or concrete block will be permitted only with specific approval of the Commission. Each building must use a minimum of two materials. 3. Indigenous natural or earth tones required. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 16 Adopted November 6, 2001 4. All flues, flashing and other reflective materials shall be painted to match and /or appropriately contrast with adjacent materials. In some cases, physical screening may be required. 5. Electric and other utility meters shall be attached to the main structure and screened to minimize contrast with adjacent materials. Exterior Walls, Roofs and Architectural Interest The Town of Avon is not comprised of a singular and unified `neighborhood' theme, however, it does contain several architecturally distinct neighborhoods. Within these neighborhoods exist a variety of exterior wall types that typify the type of design that is appropriate to our community. Requirements: 1. Exterior wall colors should be compatible with the site and surrounding buildings. The appropriate use of predominantly indigenous building materials such as native stone, wood siding, and timbers is encouraged in our mountain community. 2. Projections such as deep eaves, overhangs, canopies, and other features that provide architectural interest are encouraged. Fenestration should be articulated on large exterior walls to break up massing. At a minimum, no single wall plane should exceed 70 % of the elevation of any exposure. Breaks in the wall plane should form at least a 2 -foot step /setback. 3. All roofs, except the flat portion thereof, shall have a rise of not less than 4- inches in 12- inches of distance. Primary roofs shall have a 4:12 minimum, and a 12:12 maximum. Secondary roofs shall have a 4:12 minimum, and metal roofs shall have a 3:12 minimum. There shall be no unbroken ridgelines allowed, except on pueblo roofs that are otherwise traditionally articulated. 4. Pitched roofs shall be oriented such that excessive snow and ice does not accumulate over, or drop onto pedestrian walkways, parking areas or drives. Special protection may be required for roofs so oriented. Overhangs are required on pitched roofs, and shall extend at least one and one -half feet from the point where the wall meets the roof. 5. Roofing materials should be durable, weather resistant and suitable for environmental conditions encountered in this area. Colors should be natural or earth tones. Large expanses of bright, reflective materials will not be acceptable, however, metal such as copper, cor -ten may be acceptable. Asphalt and fiberglass composition shingles must be of high quality and minimum weight of 300 pounds per square. Untreated shakes are not permitted. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 17 Adopted November 6, 2001 An example of expressive architectural interest on a Pueblo Revival home in Wildridge. Outdoor Lighting Access to a clear and visible night sky is a strong value to our community. Light pollution is a threat to our clear skies that are part of the heritage of the Rocky Mountain West. Night lighting on a site should generally be regulated to minimize the undesirable effects that `over- lighting' a site or residence can have on a community, neighbors, and guests. At the same time, lighting is desirable for safety and aesthetic purposes. Requirements: 1. Lighting should be considered as a design feature as well as providing illumination for aesthetic and safety purposes only. There shall be no exposed light source on a property, and all fixtures must utilize frosted or seeded glass. In any case, light fixtures shall not cause glare beyond the property. 2. Floodlights are not permitted. Light spillover to adjacent properties must be minimized. No exposed bulbs are permitted. 3. Lights that flash, move, revolve, rotate, flicker, blink, or vary in both intensity and color to emit intermittent pulsation shall be expressly prohibited as fixed light sources. This does not include holiday /seasonal lighting, which is temporary in nature for the holiday /season. Duplex Developments Duplex developments must be designed in a manner that creates an integrated structure on the site. Two single- family residences `bridged' by a breezeway or other non - structural and non - habitable connection does not meet the intent of a duplex design. Unified design shall include, but not be limited to, the use of compatible building materials, architectural style, scale, massing, detail, roof forms, and landscaping. While `mirror image' duplexes are not supported, the design intent should be one that creates a unified structure with enough variety and architectural interest to distinguish a duplex from a single family home. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 18 Adopted November 6, 2001 C. Residential Landscapin Design Character Landscaping should harmonize the building site with both the natural topography and existing vegetation. All materials used should be indigenous to an area, represented by adjacent properties, and not contain any noxious weeds or undesirable exotic plants. Requirements: 1. Landscaping design should be compatible with other site improvements and with neighboring properties. 2. Not less than 50% of the useable open space area required, shall consist of pervious landscaped areas. The remaining useable open space requirements may be satisfied by impervious patio or mall type areas containing seating, decorative fountains, planters, recreational amenities and similar type facilities. 3. Consideration should be given to use of landscape material for snow fencing, visual screening and wind breaks when applicable. 4. Plant materials should be adaptable to the area and selection and placement should include Consideration of function and color coordination. A list of recommended plant species that are compatible with various climate zones found in the Town is attached in Appendix 1. No noxious weeds, as listed in Appendix 2, shall be permitted for use in the Town. 5. All lots to be covered by grass lawns shall utilize healthy sod material for complete coverage. All grass sod shall extend to the property line or, where adjacent to a roadway, to the bottom of adjacent drainage ditch or back of curb, as applicable. Fire Resistant landscaping in areas with wildfires is required. 6. An automatic irrigation system is required to reduce losses and for ease of maintenance. The landscaping site plan must include, at a minimum, a note regarding the proper installation of an automatic irrigation system, its maintenance, and intended use. Good landscaping that utilizes native vegetation should accentuate, not hide the structure. Wildridge. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 19 Adopted November 6, 2001 Fencing and Screening Fencing is discouraged, and will only be permitted where it complements the character of the property, existing grades and landforms, and compliments the landscaping rather than contain the property. Fences that delineate property boundaries are not permitted. Requirements: 1. Fences, walls, or similar type barriers shall have a separate approval of the Commission, except that functional or decorative fences or walls may be approved as an integral part of a building and landscaping design. Wood fences are generally more acceptable than metal. Limited use of fences, such as to screen trash areas and utility equipment, is encouraged. 2. Fence materials shall be compatible with the site and the materials of the structures on the site. No chain link fences shall be permitted in residential areas, except for use as a temporary construction fences or for use in public recreational facilities. The use of chicken wire, or metal screening, with split rail fencing is discouraged. However, should the fencing comply with the requirements of this section, the fenced area must be less than 1/4 of the perimeter of the property and no more than 4 feet in height. 3. Where noted by the Colorado Division of Wildlife (CDOW), accepted wildlife corridors shall be accommodated to a reasonable degree on all properties when considering the layout of site disturbances. Fencing should not delineate property lines. This type offencing is no longer acceptable. Erosion Control Erosion control is essential at all building sites. Design plans must indicate the type, method, and placement of erosion control structures on the property. A surety may be required to ensure proper installation and maintenance of these items. Required erosion control techniques and Best Management Practices (BMP's) for small residential projects are listed in the Pollution Control Plan (Appendix 4). All other projects will need to reference the Avon Master Drainage Study, available in the Community Development Department. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 20 Adopted November 6, 2001 Retaining Walls The limited use of retaining walls is encouraged. Whenever possible, retaining walls should be utilized only in those areas of a site where finished grades cannot meet recommended standards. Small retaining walls using natural stone boulders are encouraged for use and design with site landscaping. Requirements: 1. Retaining walls shall be constructed of permanent type materials such as concrete, gabions, reinforced earth, etc. Railroad ties (6x6 treated timbers) are not acceptable. Retaining wall design details may be required for design review. 2. Walls over 4 feet high shall be structurally designed or certified by a licensed engineer (P.E.). 3. A series of lower retaining walls with landscaped terraces is preferable to a high wall with an unbroken vertical face. Well landscaped and structured retaining wall use along a driveway in Wildridge. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 21 Adopted November 6, 2001 D. Residential Miscellaneous Items Accessory Structures Requirements: 1. Temporary structures including construction storage and office trailers, and tents shall not be allowed except as may be determined to be necessary during construction. 2. Permits for allowed temporary structures may be issued by the Community Development Department as a minor modification/minor project without review by the Commission. Permits shall run concurrent with building permit. 3. Any accessory structures on the building site shall be compatible with the design and materials utilized for the main building structure. Permits for accessory structures may be issued by the Community Development Department as a minor modification/minor project without review by the Commission. 4. Accessory structures must be shown on the final design site plan, and should generally be attached to the main building. The method of attachment should be generally compatible with the overall architectural design. Non - attached accessory structures are discouraged from placement on the front and sides of the building. Signs Requirements: 1. No signs, billboards, or other advertising of any kind shall be erected constructed, or maintained on any lot or structure unless approved in accordance with the provisions contained in the Sign Code of the Town of Avon (Section 15.28.00). Communications & Satellite Dish Antennae Satellite dishes are permitted in residential areas, however, with restrictions on screening these dishes from neighboring properties. Screening may be accomplished through the placement on a building; however, a separately built fence /screen may not be used. Requirements: 1. All antennas shall be located so as to be screened from view from any public right -of -way or neighboring property. Screening may be accomplished by, or through the use of landscaping materials, existing structures, sub -grade placements or other means that both screen the antennas and appear natural to the site. 2. All wiring and cable related to antennas installation shall be installed underground or be incorporated entirely within the structure. 3. Color selection for dish antennas should blend with the site and structure. Unpainted surfaces and dish antennas with reflective surfaces shall not be allowed, and surfaces are required to be painted to match adjacent surfaces. No advertising, logos or identification shall be allowed on any dish antenna. Above Ground Tanks and Miscellaneous Structures Requirements: 1. Oil, gasoline or liquid petroleum gas tanks will not normally be permitted on or above ground. Temporary installations for a period not exceeding 2 years may be approved provided the installation complies with all applicable regulations and is fully screened from view from all public rights -of -way and neighboring properties. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 22 Adopted November 6, 2001 2. No outdoor clotheslines, trash receptacles, or storage areas will be permitted unless screened. 3. Screening details shall be reviewed and approved by the Commission prior to installation. 4. Flues, vents, chimneys, and other mechanical penetrations of a roof on any structure shall be fully enclosed and screened in such a manner as to conform to the overall design character, and equipped with spark arrestors. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 23 Adopted November 6, 2001 5. Commercial and Industrial Development Guidelines The overall design theme for the Town should be consistent with the dominant character of existing development, to establish and attractive appearance for visitors and residents, and yet be flexible enough to allow affordable design solutions. The architectural styles of the existing buildings vary greatly. However, most of them can be described as contemporary, having in common, pitched roofs, stepped facades, recessed windows, balconies, and subtle colors (gray, cream, tan and brown). In contrast, there are a few buildings that have vibrant blue or red roofs, or long blank, windowless walls. These buildings are the exception rather than `the norm'. A contemporary commercial building in downtown Avon. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 24 Adopted November 6, 2001 A. Commercial and Industrial Site Development Site design Buildings and other improvements should be individually designed for the site on which they are to be placed. The site and its relationship to other structures, scenic values, views, and climatic orientation should be the dominant factors in the design and sighting of buildings. Pedestrian access ways should be aligned and focused on architectural or aesthetic features. Requirements: 1. Site layout and proposed improvements shall consider the use of passive and active solar use, and the retention of neighboring properties `view corridors'. 2. The location of structures and access shall complement the existing topography of the site. Excessive grading and/or the use of engineer- designed retaining walls is discouraged when an alternate site layout would minimize such disturbances. 3. Buildings and improvements shall be designed and sited to conform to the natural terrain and to take advantage of views. Terraced buildings and parking will minimize site disturbance, and disturbed areas should be revegetated with recommended plant species listed in Appendix 1. The use of listed noxious weeds, as provided in Appendix 2, is prohibited. 4. Where no development has been identified, construction shall at a minimum avoid: all drainage and utility easements, development setbacks, areas over 40% in slope, and unique and sensitive natural site features. 5. The use of sun exposure- reducing elements such as overhangs, pergolas, canopies, eaves and awnings should be designed as integral components of the architectural design. Passive solar design is encouraged. However within these spaces, there should be a variety of sun and shade conditions to allow full use during the extreme heat of summer months and take advantage of warm winter days. North facing entries and outdoor space such as courtyards and plazas should be carefully considered because of winter conditions. F91 S&Vth&Act 6, ��.� c ow'tyi rd :!�'o %r Expesure Views 'rear /aceed buil4;n r Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 25 Adopted November 6, 2001 Site Access Access to the building site requires consideration of topography and building orientation. Avoidance of steep slopes, the blending of access with the natural contours of a site, and sensitivity to solar orientation, are important in establishing a successful access. Where access drives connect to public streets, drainage and landscape maintenance are the responsibility of the owner. Additionally, heated driveways must not exceed the property line. Requirements: 1. Adequate distance from intersections and proper relation to other entrances. 2. Satisfactory width, grades, radii etc. as indicated in Table 1.0. 3. Turn lanes, if required by the Town Engineer, shall be designed in accordance with requirements indicated in Table 1.0. 4. Residential projects with 6 or fewer units shall be restricted to a single point of vehicle access from the public right -of -way. Additional points of access must be specifically approved by the Planning & Zoning Commission, with the finding that additional access points are required for the project to otherwise conform to these Design Standards and other applicable Town regulations. 5. The grade of the first 20 feet of driveway adjacent and perpendicular to the paved public way shall not exceed 4% grade. 6. Parking lot grades should not exceed 6% and driveway grades should not exceed 8% for multi - family residential, mixed -use, and commercial projects or 10% for small residential projects. 7. The grade of the first 20 feet of driveway adjacent to the garage or outside parking space shall not exceed 4% grade. 8. Project site plans shall include provisions for emergency vehicle access when required. 9. Adequate maneuvering for all vehicles on site must be provided. Parkin! and Loadin Surface parking is discouraged in the pedestrian oriented commercial areas of the Town, except for short-term use and service functions. The predominant parking functions should occur in structured parking areas for large commercial projects. The more vehicular oriented commercial core area is designated for surface parking. Requirements: 1. Required spaces provided must be in compliance with standards set forth in Section 17.24.020 of the Town of Avon Zoning Code. 2. All spaces must be accessible and meet minimum size requirements as required in Section 17.24.020 of the Town of Avon Zoning Code. 3. All parking must be off - street. Ninety- degree stalls are encouraged. Complete vehicular circulation including back -up and turn- around areas must be provided. 4. Parking areas must be concrete or asphalt with spaces clearly marked. Two handicapped stalls per each 100 stalls is recommended. Snow storage areas equaling 15% of all parking areas are recommended. 5. Driveway or maneuvering areas within a parking lot must be designed to provide for safe and reasonable maneuverability of vehicles. 6. Parking areas should include landscaping and screen surface parking. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 26 Adopted November 6, 2001 Landtz -aP-cl bland TO Min. Parkins Arca Interior Landscaping vo i F_arih 8crrns Larth Serms d. Lands -arc. Pa rking L 01 SEIreeniny Easements Disturbance in drainage and utility easements should be avoided. Landscaping placed in easements may be subject to removal and are the responsibility of the property owner to replace and maintain. Trees placed in drainage easements paralleling public streets may be damaged or destroyed by Town maintenance operations. Requirements: 1. Dedicated easements shall remain unobstructed unless they are officially vacated. 2. Landscaping improvements shall avoid placement in easements whenever possible. Any landscaping improvements placed in easements shall be the responsibility of the property owner to maintain and replace should they be damaged or destroyed by the Town or local service district while doing drainage, snowplowing, or utility work. Site Grading Grading a property should be minimized, and only done as necessary for building improvement. Grading required in easements and setbacks is expected to be restored and revegetated to natural conditions before site construction is complete. Where finished grades require retaining wall placement, a series of lower retaining walls with landscaped terraces is preferable to a high wall with an unbroken vertical face. Requirements: 1. Site improvements should be designed to conform with existing site topography to minimize required grading and effect on adjacent properties. All grading shall occur within the property boundaries. Both existing and finished grades are required to be clearly marked on the site plan submittal, to the extent specified on the Minimum Submittal Requirements (Appendix 3) checklist. 2. Maximum slope of disturbed slopes shall not exceed 2 feet horizontal to 1 foot vertical without special documentation and review. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 27 Adopted November 6, 2001 3. Horizontal and vertical variations in grading cut and fill areas should resemble a natural configuration. Long slopes should be varied to avoid the appearance of flat surfaces, unless the original slope was in this configuration prior to grading. 4. Building sighting and foundation excavation shall avoid the disruption of existing natural features such as mature trees whenever possible. 5. All grading, including utility connections, is required to be shown within the proposed `site disturbance boundary' on submitted application plan sets. 6. All grading shall require erosion control methods so that dirt and fill material does not leave the property on to the public right of way and adjacent properties. A surety may be required for the proper installation and maintenance of erosion control. 7. All graded areas shall be revegetated as soon as practicable during the construction process. Dust suppression and the prevention of noxious weed infestation is the responsibility of the owner /developer. 8. Retaining walls shall be constructed of permanent type materials such as concrete, gabions, reinforced earth, etc. railroad ties are not acceptable. Retaining wall design details may be required for design review. 9. Walls over 4 feet high shall be structurally designed or certified by a licensed engineer (P.E.). Drainage Adequate grading plans ensure that drainage is functional on a building site. The builder is responsible for preventing erosion of the site both during construction and after the project is complete. Grading plans must adequately demonstrate positive drainage away from building structures. Requirements: 1. All drainage easements shall remain unobstructed. Drainage into common open space is not allowed except in existing natural drainage channels or drainage easements. Drainage swales should not surface drain across major walkways or trail systems. Parking bays and walkways should not slope toward the building without adequate provisions for draining stone water away from the structure. All paved areas must be sloped to drain. 2. All structures shall be located above or be protected from the 100 -year floodplain, where identified by FEMA mapping. Where mapping is unavailable, the Town may require a qualified engineer to conduct an analysis of whether or not the proposed structures are proposed in a floodway or floodplain. 3. Minimum setback of thirty feet shall be maintained from mean annual high water mark of all continuously flowing streams. 4. All development shall conform to the Town of Avon Drainage Design Manual, as part of the Master Drainage Study (Sept. 1994). (Appendix 5). 5. All construction projects shall conform to the Town of Avon Pollution Control Plan Manual. (Appendix 4). Snow Removal and Storage The Town of Avon receives varying amounts of precipitation depending on aspect and elevation, typically in the form of snow. However, all sites must be able to adequately accommodate and transport snow on site in conjunction with approved drainage easements. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 28 Adopted November 6, 2001 Requirements: 1. An area equal to 20% of the total impermeable surfaced area of the site, upon which aboveground construction does not occur, shall be designated and developed as a snow storage area. 2. Designated snow storage areas shall be located and developed to be compatible with snow removal operations, not less than six (6') feet wide, and shall be adjacent to the impermeable area from which the snow is to be removed. 3. Runoff from snow storage areas shall be directed through a treatment facility as required for treatment of runoff from parking and driveway areas. 4. On -site snow storage requirements may be waived by the Planning and Zoning Commission upon the demonstration that an appropriate alternative snow - storage site is available and that arrangements have been made for the continuation of snow removal and off -site storage. 5. Excavation, retaining walls, or other structures within slope maintenance and snow storage easements adjacent to public rights -of -way shall be confined to those strictly required for effective site access. Water and Sewer, Trash Storage Each site design shall address the availability and design of water and sewer service, along with trash storage on the lot. Trash storage must be identified on the site plan, including design detail, for all multi- family units greater than a duplex. Requirements: 1. Each structure designed for human occupancy shall be connected with water and sewer facilities made available by existing water and sewer districts. Letters of commitment from the appropriate districts may be required. 2. No private wells or sewer systems shall be used within the Town except as provided in the Subdivision Regulations. 3. Each project shall have receptacles for the temporary storage and collection of refuse. The handling of trash for all projects larger than a single - family unit (i.e. duplex, triplex) shall be noted on the site plan. When necessary, bear resistant trash receptacles may be required. 4. All trash receptacles shall be screened from public view and protected from disturbance. 5. Refuse storage area shall be accessible by collection vehicles and should be incorporated into building design whenever possible. Non - combustible receptacles only for ash. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 29 Adopted November 6, 2001 A well- screened and attractive service and trash enclosure at the Brookside Lodge. Sidewalks As necessary in certain commercial subdivisions and planned unit developments, the inclusion of sidewalks on a property may be required by the Town to provide a neighborhood amenity. Requirements: 1. Sidewalks or walkways should be provided as necessary for efficient pedestrian circulation within the project and with neighboring properties. Walkways should be separated from vehicular traffic where possible. 2. Walkways should be constructed of attractive, durable materials such as decorative concrete or brick pavers. 3. Walkway widths should be compatible with anticipated uses, but in no instance, shall be less than 4' wide as a minimum standard. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 30 Adopted November 6, 2001 B. Commercial and Industrial Building Desiqn General Commercial Design Character In addition to the stated Design Philosophy, and General Design Compatibility, buildings should be designed to maximize energy efficiency by limiting windows and doors on the north, and taking advantage of sun exposure on the south. Additionally, building design and location should generally minimize impacts on solar and view corridors of neighboring properties Building facades should be stepped to avoid long straight walls, and entrances should be recessed. All sides of buildings should receive equal architectural treatment. Windows should be placed to provide architectural interest. Large, uninterrupted glass areas should be avoided. At the pedestrian scale, buildings should contain quality design details that are harmonious with the overall building architecture. Rooftop equipment and vents, as well as trash disposal and service areas, should be concealed with a treatment that is complementary to the building architecture. It is preferred that buildings be designed as a composition of architectural elements rather than larger single `blocks' that appear unrelated in form and context. Building Height The height of structures, unless otherwise specified in a planned unit development, shall conform to the zone district limitations stated in Title 17: Zoning_ Regulations. The definition of height is set forth in the `Definitions' section of these guidelines. No exceptions to the height requirements shall be made, except as specifically approved for penetrations of certain architectural projections such as flues, chimneys, cupolas, towers or other elements that may have the potential to add architectural character and variety to the skyline. Solar access is of primary importance within the town core, and commercial designs may be required to provide solar access studies showing the effect of shading on adjacent buildings and outdoor spaces (Sun studies should be prepared on a site plan of a scale not less than 1 " =40' showing shadows at noon on March 21, June 21, September 21, and December 21). Building Height will be determined by utilizing the site development plan and elevations. All ridge elevations, and numeric existing and proposed grades must be labeled on the site plan to accurately determine height. Additionally, the elevation plans must show existing and proposed grades (also labeled in numeric form), such as the illustration above. Building Materials and Colors The intent of these guidelines is to provide architectural control to "ensure that the architectural design of structures and their materials and colors are visually harmonious with the town's overall appearance, with surrounding development, with natural and existing landforms, and with officially approved development plans ". These guidelines should represent the minimum standard to achieve this goal, without being so cumbersome as to not allow varied high - quality design that meets this intent. Requirements: 1. The use of high quality, durable, low maintenance building materials is highly encouraged. 2. The following materials and wall finishes will not ordinarily be permitted on the exterior of any structure: asphalt siding, imitation brick, asbestos cement shingles or siding, imitation log siding or plastic. Metal siding, concrete or concrete block will be permitted only with specific approval of the Commission. Each elevation must use a minimum of two materials (i.e. stucco, siding, wood). 3. Natural or earth tones are encouraged as the dominant color with brighter colors used for accent. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 31 Adopted November 6, 2001 4. All flues, flashing and other reflective materials shall be painted to match and /or appropriately contrast with adjacent materials. In some cases, physical screening may be required. 5. Electric and other utility meters shall be attached to the main structure and screened to minimize contrast with adjacent materials. Roofs Roof forms are strong determinants of architectural style. Due to climatic conditions, roof forms should be kept simple, with pitches limited to 6:12 to 12:12 for sloped roofs. Flat roofs are discouraged except for limited roof areas for the location of concealed mechanical equipment, or for architectural effect. Secondary shed -type roofs should,have pitches no less than 4:12. Valleys and complex roof forms are a potential source of ice buildup and water damage, and should be used carefully and sparingly. Requirements: 1. The use of dormers (shed, peaked, eyebrow, etc.) is encouraged to help break up large expanses of roof, to enhance the usability of attic spaces, and to add interest to the roof- scape. 2. Roofing materials should be durable, weather resistant and suitable for environmental .conditions encountered in this area. Colors should be natural or earth tones. Large expanses of bright, reflective materials will not be acceptable. Asphalt and fiberglass composition shingles must be of high quality and minimum weight of 300 pounds per square. Untreated shakes are not permitted. 3. In the Town Core unglazed concrete, copper, standing seam metal, or terne- coated steel are acceptable materials (Shake shingles, asphalt, and fiberglass roofs are generally discouraged). Tile should be used in a dull finish in colors. Metal roofs with a dull finish may also be considered, however colors should be muted to fit within the context. 4. All roofs, except the flat portion thereof, shall have a rise of not less than 4- inches in 12- inches of distance. 5. Pitched roofs shall be oriented such that excessive snow and ice does not accumulate over, or drop onto pedestrian walkways, parking areas or drives. Special protection may be required for roofs so oriented. Overhangs are required on pitched roofs, and shall extend at least one and one -half feet from the point where the wall meets the roof. Minimum overhang length is 18 inches. 6. Exposed metal flashing, gutters, downspouts or other building appurtenances must be copper, steel, iron, or aluminum, applied and fastened in a high - quality manner. When painted, these elements must be finished with a baked enamel paint, epoxy paint, or a silicon- modified alloy. 7. Snow shedding is a major concern that must be carefully considered in the designing roofs. Building entries, garage and service doors, shop fronts, and other points of entry must be located out of the path of shedding snow. Gable fronts, covered porches, balconies, and snow retention devices are all acceptable methods of dealing with snow shedding off of sloped roofs. Landscape features such as retaining walls or raised planters may also be used to direct pedestrians out of the way of snow or ice shed areas. Where removal of snow from roofs is anticipated, mechanical and safety devices should be provided, as well as easy access to the roof. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 32 Adopted November 6, 2001 Interesting roof forms add character, such as those found in the Westgate PUD. Exterior Walls The form of exterior walls in the commercial areas of the Town should grow out of a balanced response between the public spaces they front and the interior functions they enclose. Walls can be broken down in scale through the use of windows, doorways, recesses and setbacks. They should be further articulated through the use of different materials, patterns, ornament, texture, and color. Walls should also respond to solar exposure in their placement. Exterior walls should attempt to enclose exterior space and to create a sense of `street'. This encourages the linkage of one building to the rest, and the continuation of urban form as opposed to individual buildings in the landscape. Requirements: 1. Stucco and synthetic stucco are suitable on upper walls of buildings. Joints, variety or color, and changes in plan should create a sense of scale on stucco walls. 2. Stone elements should be used when appropriate on the base of larger buildings, up the walls, or in elements such as chimneys or towers. Roughly squared stone set in a random pattern is preferable to more formal uses of stone. In large walls, stone should be set with larger stones at the bottom gradually diminishing to smaller stones at the top. 3. Projections such as deep eaves, overhangs, canopies, and other features that provide architectural interest are encouraged. Fenestration should be articulated on large exterior walls to break up massing. At a minimum, no single wall plane should exceed 70 % of the elevation of any exposure. Breaks in the wall plane should form at least a 2 -foot step /setback. 4. Wood siding should be avoided in commercial building where it will be in contact with snow (at the base). The scale of wood siding (4 ", 6 ", 8 ", or larger) should be appropriate and complement the desired design of an exterior wall space. 5. Exterior elements such as porches, roof overhangs, dormers, and gables should utilize heavy timber when appropriate to create interest, give scale, and signify areas of architectural importance. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 33 Adopted November 6, 2001 6. Poured -in -place or pre -cast concrete may be used where appropriate as column and spandrel covers. At grade or poured -in -place walls with large stone aggregate are examples that may be acceptable use of concrete in some commercial structures. Windows Windows establish patterns, rhythms, and scale on the exterior walls. They respond to uses and needs on the interior and are recognizable indications of what goes on behind them. Variety in the use of windows is encouraged within certain limits. Commercial spaces must have large areas of glass opening onto public pathways, streets, or sidewalks (suggested goal is 75% glass). Hotels and other private uses should have more limited use of glass. In all cases, large uninterrupted areas of glass are discouraged. Division of windows by mullions and muntins adds character and gives scale to the building. Requirements: 1. Aluminum, steel, painted wood, or clad wood windows are permitted in all commercial areas. Mirrored glass, snap -in muntins, glass curtain walls, and other assemblies which are clearly out of character with the Town Core are prohibited. 2. Pedestrian level windows in commercial spaces require a minimum allowable glass area of 75% of walls opening on to the ground/pedestrian level. The maximum size of individual panes of glass is not to exceed 16 square feet without special review. In general, areas of glass unbroken by wall or structure should not exceed 150 square feet. 3. Pedestrian level windows in hotel or office spaces should be as open as possible and not less than 50% glass, unless it is a north exposure, in which case glass may be reduced to 40 %. The same restrictions apply to sizes of individual panes and areas of glass unbroken by wall or structure. 4. All upper levels of commercial, hotel, and/or office area have no requirements for percentage of window to wall, but are restricted to individual panes of a maximum of 10 square feet and a maximum overall glass area of 48 square feet per window opening. 1 W(/ 7r i f- .. own" !n Wes/ Wi'ndow5 Doors and Entryways J � AaX m Public doors and entryways within the Town should be a combination of glass and metal or wood, or solid wood. All -glass or all -metal doors are discouraged. Doors should be used to establish interest, character, and variety along the public right -of -way. Where possible, gates, courtyards, staircases, and bridges should be used to connect building sand create outdoor rooms and linkages. Service doors may be hollow metal or solid wood in hollow metal frames. Main entries should not be placed on the north side of buildings unless no other alternative exists. When a main entry occurs on a north fagade it should be covered with a porch or porte cochere. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 34 Adopted November 6, 2001 L800,wa yS Decks and Balconies and Exterior Walkways Decks and Balconies become part of the design palette used to enrich the character and create variety on the building exteriors. Where possible, balconies and decks should be located to take advantage of solar exposure, and should be used in combination with bay windows and other exterior projections. Long, linear balconies such as might appear on a common motel are discouraged in the Town. Care should also be taken in locating walkways to avoid placing them in areas which are in shadow all winter long. On the north side of buildings, sidewalks should either be covered or far enough away from the building to be out of its shadow for several hours each day. 7"hls Outdoor Lighting & A/S Lighting systems will serve functional and aesthetic roles in commercial areas. These roles are: to provide security and visual safety, to serve as directional indicators for both vehicular and pedestrian traffic; to provide extended outdoor use time, particularly in pedestrian gathering areas; and to reinforce the identity and character of a project through form, color and materials of fixtures, visual light quality, and placement. Access to a clear and visible night sky is a strong value to our community. Night lighting on a site should generally be regulated to minimize the undesirable effects that `over - lighting' a site can have on a community, neighbors, and guests. At the same time, lighting is desirable for safety and aesthetic purposes. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 35 Adopted November 6, 2001 Requirements: 1. Lighting should be provided for all parking, drive, and walkway areas and may be required as a condition of design approval. In all commercial, retail and office parcels, lighting must be designed and arranged so as not to reflect excessive light upon abutting or adjacent properties. Floodlights are not permitted. 2. Lighting should be considered as a design feature as well as providing illumination. Area lighting shall generally be a metal halide, cut -off type fixtures with a maximum mounting height of 15 feet for walkways and 25 feet for parking areas. There shall be no exposed light source on a property, and all fixtures must utilize frosted or seeded glass. 3. Pedestrian areas should utilize low -level light sources to accent or illuminate the ground plane. These design elements should provide light for safety and aesthetic effect. By day, the physical shapes and sizes lend animation and scale to pedestrian spaces. 4. Lights which flash, move, revolve, rotate, flicker, blink, or vary in both intensity and color to emit intermittent pulsation shall be expressly prohibited as fixed light sources. This does not include holiday /seasonal lighting, which is temporary in nature for the holiday /season. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 36 Adopted November 6, 2001 C. Commercial and Industrial Landscapin Design Character Plant material selection and placement must ensure safe sight lines to traffic and signs. Care should be taken that no hazards are created for pedestrians and vehicles by plant litter. Trees and shrubs with thorns should not be used in or near pedestrian areas. All landscape development for commercial projects, including specific landscaping elements such as planters, retaining walls and berms must be specifically approved. Landscaping should accentuate a project design, not hide it from public view. Requirements: 1. Landscaping design should be compatible with other site improvements and with neighboring properties. 2. Trees should be massed or grouped together whenever possible to provide a greater visual impact. Tree plantings may not interfere with utility or drainage easements, and their location should be based on a function such as screening, shade, view enframement or accent. Accent plantings should occur at locations such as building entries, parcel entries, or pedestrian areas. Evergreen locations should consider shading sidewalks in winter to avoid creating hazardous icing conditions, as well as avoiding south facing windows that may be impaired to solar access. 3. Not less than 50% of the useable open space area required, shall consist of pervious landscaped areas. The remaining useable open space requirements may be satisfied by impervious patio or mall type areas containing seating, decorative fountains, planters, recreational amenities and similar type facilities. 4. Consideration should be given to use of landscape material for snow fencing, visual screening and wind breaks when applicable. Hedges, in winter, become snow fences and must be placed accordingly. 5. Plant materials should be adaptable to the area and selection and placement should include Consideration of function and color coordination. A list of recommended plant species that are compatible with various climate zones found in the Town is attached in Appendix 1. No noxious weeds, as listed in Appendix 2, shall be permitted for use in the Town. 6. Grasses should be used close to pedestrian areas where visual relief from extensive pavement is desired, or, in large open areas as a soils stabilizing agent for visual effect (primarily viewed from vehicular traffic). All grass sod shall extend to the property line or, where adjacent to a roadway, to the bottom of adjacent drainage ditches or back of curb, as applicable. Fire Resistant landscaping in areas with wildfires are required. 7. In large open areas numerous grass mixes should be considered depending on water requirements and availability, maintenance requirements, potential fire hazard of dry grass, and visual effect desired. In these areas, rough grass mixes should be utilized. Native grasses and wildflower mixes require less water, less mowing and lend themselves well to the perimeter areas of the Town Center blending into the existing vegetation. An automatic irrigation system is required to reduce losses and for ease of maintenance. The landscaping site plan must include, at a minimum, a note regarding the proper installation of an automatic irrigation system, its maintenance, and intended use. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 37 Adopted November 6, 2001 Well placed landscaping on a commercial projects accentuates the project features. Fencing and Screening All commercial service areas are to be screened from adjacent land uses by architectural features such as solid four -foot or six -foot fences, and/or heavily massed plant materials. All fences, whether decorative or for screening must be constructed of wood; masonry walls will only be considered if they are designed as an integral component of the building's architecture. Buffering may be required by architectural features if excessive noise levels are anticipated or encountered. Requirements: 1. Loading and unloading facilities must be separated from employee, customer and visitor circulation and parking areas wherever feasible. All service areas, loading and unloading docks must be screened from public view. 2. Ground - mounted equipment such as power transformers and air handling equipment must be screened from public view by either materials integral with the building, a fence or landscaping, all of which must be specifically approved for the site. Trash dumpsters shall be screened by a six -foot fence or wall similar in character to the adjacent structure, with access gates as necessary. 3. Fence materials shall be compatible with the site and the materials of the structures on the site. Fencing may be used in combination with plant materials. In all cases, however, plant materials must be used to screen utility boxes. Meters, phone pedestals, and transformers will occur to the side and rear of the building whenever possible and be appropriately screened. 4. No wall, fence, or planter in excess of two -feet in height should be constructed or maintained nearer to the front lot line than the front building setback line. No front, side or rear fence, wall or hedge may be more than six -feet in height. 5. Fences should be either one of three types in commercial areas: two (split) rail open fences, four -foot solid fence, or a six -foot solid fence. No chain -link permitted. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 38 Adopted November 6, 2001 r�rr a VIEW. IV TWO FairOren Erosion Control 11114fllllllllllll {IfAlllilllll� � �Iillllll IIIlllllll� �'IIIIIIIIIIIiIIIIIIIUUINIII Erosion control is essential at all building sites. Design plans must indicate the type, method, and placement of erosion control structures on the property. A surety may be required to ensure proper installation and maintenance of these items. All commercial projects will need to reference the Avon Master Drainage Study, available in the Community Development Department for minimum requirements. Retaining Walls The limited use of retaining walls is encouraged. Whenever possible, retaining walls should be utilized only in those areas of a site where finished grades cannot meet recommended standards. Small retaining walls using natural stone boulders are encouraged for use and design with site landscaping. Requirements: 1. Retaining walls shall be constructed of permanent type materials such as concrete, gabions, reinforced earth, etc. railroad ties are not acceptable. Retaining wall design details may be required for design review. 2. Walls over 4 feet high shall be structurally designed or certified by a licensed engineer (P.E.). A series of lower retaining walls with landscaped terraces is preferable to a high wall with an unbroken vertical face. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 39 Adopted November 6, 2001 D. Commercial and Industrial Miscellaneous Items Accessory Structures Requirements: 1. Temporary structures including construction storage and office trailers, and tents shall not be allowed except as may be determined to be necessary during construction. 2. Permits for allowed temporary structures may be issued by the Community Development Department as a minor modification/minor project without review by the Commission. Permits shall run concurrent with building permit. 3. Any accessory structures on the building site shall be compatible with the design and materials utilized for the main building structure. Permits for accessory structures may be issued by the Community Development Department as a minor modification/minor project without review by the Commission. 4. Accessory structures must be shown on the final design site plan, and should generally be attached to the main building. The method of attachment should be generally compatible with the overall architectural design. Signs Well- designed and constructed signs attract attention, create a sense of quality and contribute to the overall urban character of the Town. In general, all signs must conform to the Town of Avon sign code unless otherwise conforming to another approved Master Sign Program. All building mounted signs should be located on a fascia or architectural detail designed for such purposes. Freestanding identification signs should reflect the architectural character of the building. Flush mounted signs are encouraged with projecting signs allowed to any adjacent walkway or pedestrian mall. Requirements: 1. No signs, billboards, or other advertising of any kind shall be erected constructed, or maintained on any lot or structure unless approved in accordance with the provisions contained in the Sign Code of the Town of Avon (Section 15.28.00). Communications & Satellite Dish Antennae Satellite dishes are permitted in commercial areas, however, with restrictions on screening these dishes from neighboring properties and prominent views. Screening may be accomplished through the placement on a building, however, a separately built fence /screen may not be used. Requirements: 1. All antennas shall be located so as to be screened from view from any public right -of -way or neighboring property. Screening may be accomplished by, or through the use of landscaping materials, existing structures, sub -grade placements or other means that both screen the antennas and appear natural to the site. 2. All wiring and cable related to antennas installation shall be installed underground or be incorporated entirely within the structure. 3. Color selection for dish antennas should blend with the site and structure. Unpainted surfaces and dish antennas with reflective surfaces shall not be allowed, and surfaces are required to be painted to match adjacent trim surfaces. No advertising, logos or identification shall be allowed on any dish antenna. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 40 Adopted November 6, 2001 Above Ground Tanks and Miscellaneous Structures Requirements: 1. Oil, gasoline or liquid petroleum gas tanks will not normally be permitted on or above ground. Temporary installations for a period not exceeding 2 years may be approved provided the installation complies with all applicable regulations and is fully screened from view from all public rights -of -way and neighboring properties. 2. No outdoor clotheslines, trash receptacles, or storage areas will be permitted unless screened. 3. Screening details shall be reviewed and approved by the Commission prior to installation. 4. Flues, vents, chimneys, and other mechanical penetrations of a roof on any structure shall be fully enclosed and screened in such a manner as to conform with the overall design character, and equipped with spark arrestors. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 41 Adopted November 6, 2001 6. Application and Processing Submittal and Review Process The Design Review process is broken down into three distinct tiers: Pre - application Meeting, Sketch Plan Review, and Final Design Review. Community Development shall review all material submitted for either of the three design review tiers to determine whether an applicant has met the minimum submittal requirements prior to the scheduling of a meeting or public hearing. Minimum submittal requirements are attached as a `checklist' for each required application, and should be reviewed carefully. For Sketch and Final Design Review, if the application and supporting material is found to be inadequate, the Community Development Department shall not schedule the application for consideration by the Commission but shall notify the applicant of any inadequacies. Such notice will be provided in writing within 7 days of receipt of application. The following outlines the entire design review application process: Pre - application Meeting The applicant shall prepare at least two (2) copies of the following for staff review and comment prior to Pre - application Meeting: 1. A Survey of the property, prepared by a licensed surveyor, showing property boundaries, area, easements, building setbacks, building envelopes, topography (at 2' intervals @ 1 " =20' eng. scale), and any significant natural features such as watercourses, mature tree stands, and rock outcroppings. 2. A Conceptual Site Plan, Architectural, and Elevations (1/4 " =1'0" arch. scale) including all property boundaries, proposed building footprints, easements, and driveways. The applicant is requested to bring the specific information requested above to a scheduled pre - application meeting with staff for review. The intent of this meeting is to provide sufficient direction for the applicant to be prepared to submit a Sketch Plan that meets all requirements. Sketch Plan Review The applicant shall submit four (4) hard line copies of the following for a Sketch Plan Review: 1. A Survey of the property, prepared by a licensed surveyor (stamped and signed), showing property boundaries, area, easements, building setbacks, building envelopes, topography (at 2' intervals @ 1 " =20' eng. scale), and any significant natural features such as watercourses, mature tree stands, and rock outcroppings. 2. A Site Plan (1 " =20' eng. scale) which clearly indicates existing and proposed grades, all property boundaries, proposed building footprints, easements, driveways and proposed driveway grades, limits of site disturbance, all building ridgeline elevations, and any proposed detention structures. 3. Architectural Drawings (at 1/4 " =1'0 arch. scale) which clearly indicate dimensioned floorplans, exterior elevations with all ridge and grade elevations labeled, roof plans, material placement and use, overall building dimensions, and building height calculations. A specific `Minimum Sketch Plan Review Submittal' (Appendix 3a) checklist is provided with the application, and the applicant is requested to review and check each item carefully to ensure a complete application prior to submittal. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 42 Adopted November 6, 2001 Final Design Review The applicant shall submit four (4) hard line copies of the following for a Final Design Review: 1. A Survey of the property, prepared by a licensed surveyor (stamped and signed), showing property boundaries, area, easements, building setbacks, building envelopes, topography (at 2' intervals @ 1"=20' eng. scale), and any significant natural features such as watercourses, mature tree stands, and rock outcroppings. 2. A Site Plan (1 " =20' eng. scale) which clearly indicates existing and proposed grades, all property boundaries, proposed building footprints, easements, driveways and proposed driveway grades, limits of site disturbance, temporary/construction trailers, all building ridgeline elevations, and any proposed detention structures. 3. An Architectural Plan (at 1/4 " =1'0 arch. scale) which clearly indicates dimensioned floorplans, exterior elevations with all ridge and grade elevations labeled, roof plans, material placement and use, overall building dimensions, and building height calculations. 4. A Landscaping Plan (1 " =20' eng. Scale) which clearly indicates existing and proposed grades, all proposed landscaping locations, landscaping materials employed, irrigation system (noting minimum use and approximate area), erosion control placement and type, and any required revegetation for disturbed areas (by type and placement). 5. A Color Board that clearly indicates all materials employed on the exterior of the stricture, including but not limited to: siding, stucco, wood, finishes, paints and stains, roof materials, window and door type and casement colors, and soffit and fascia treatments. All materials will be indicated with a representative sample from the manufacturer, including the model number /name, and shall be keyed to placement on the Architectural Plan elevations. Color Board must be no larger than 81/2 x 11(Please reference Appendix 6). 6. A Lighting Fixture Cut - Sheet, provided by the manufacturer of the product, which clearly indicates the type of fixture being used. All lighting shall be keyed to placement on the Architectural Plan. 7. A colored elevation of the design submittal, as closely as possible representing the type, placement, and accurate representation of materials being employed. A specific `Minimum Final Design Review Submittal' (Appendix 3b) checklist, in addition to minimum requirements of the Pollution Control Plan and Stormwater Control Plan/Drainage Design Manual, is provided with the application, and the applicant is requested to review and check each item carefully to ensure a complete application prior to submittal. Applicants are encouraged to ask staff for direction or clarification with the minimum submittal requirements at any time. Additionally, the minimum submittal checklist may be updated on occasion, so applicants are encouraged to contact the Community Development Department to ensure that they are utilizing the most recent checklist available. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 43 Adopted November 6, 2001 7. Planning and Zoning Commission Review The Planning and Zoning Commission shall consider the application and supporting material and shall approve, conditionally approve, deny approval or continue the design review of the project within 45 days of the date of the meeting at which the complete application and supporting material is first reviewed by the Commission. If the Commission determines that advice or assistance of professional consultants is needed, or that additional information is required from any source, an additional 45 days shall be permitted for action by the Commission. General Approval Criteria All applications must meet the following general regulatory and planning criteria to be approved: 1. The project complies with the Town of Avon Zoning Regulations, 2. The project has general conformance with Goals and Policies of the Town of Avon Comprehensive Plan, and any sub -area plan which pertains, and 3. There exist adequate development rights for the proposed improvements. Sketch Plan Approval Criteria The Commission and Staff shall evaluate the design of all sketch plan projects utilizing the specific Design Standards, and by using the following general criteria: A. The conformance with setbacks, massing, access, land use and other provisions of the Zoning Code. B. General conformance with Sections A through D of these guidelines, the design philosophy, and design intentions listed herein. Sketch plan approvals shall not be vested, but may be applied towards the submittal of a final design plan for up to six (6) months. Final Design Plan Approval Criteria The Commission shall evaluate the design of all final design plans utilizing the specific Design Standards, and by using the following general criteria: A. That the final design plan is in compliance with all sketch plan approval criteria and with all final design plan submittal requirements. B. The compatibility of proposed improvements with site topography, to minimize site disturbance, orient with slope, step building with slope, and minimize benching or other significant alteration of existing topography. C. The appearance of proposed improvements as viewed from adjacent and neighboring properties and public ways, with respect to architectural style, massing, height, orientation to street, quality of materials, and colors. D. The objective that no improvement be so similar or dissimilar to others in the vicinity that monetary or aesthetic values will be impaired. E. The general conformance of the proposed improvements with the adopted Goals, Policies and Programs for the Town of Avon. Final Design Plan approval shall be valid for a period of two (2) years from the date of approval, with an one -time extension permitted for up to one year at the applicant's request. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 44 Adopted November 6, 2001 Basis for approval or denial of project design If the design of any project is found to comply with the purposes prescribed in these Guidelines, Regulations, and any applicable Ordinances of the Town of Avon, and the design guidelines review criteria prescribed in Section 7 of these Regulations, the Planning and Zoning Commission shall approve the project. If the Commission determines that a conflict exists with the purposes, the design guidelines, or any other provision of those Regulations or any Ordinance of the Town of Avon, which would prevent approval of such project, the Commission shall disapprove the project. If the Commission determines that conflicts exist which are subject to correction, the Commission may conditionally approve or request changes to conform with the design guidelines or other provisions of those regulations. Any disapproval, conditional approval or request for changes shall be in writing and shall specifically describe the purpose, statement, or design guidelines with which the design of the project does not comply and the manner of noncompliance. Notification of an application decision shall be made by the recording secretary and transmitted in writing to the applicant within 7 days of said meeting. Compliance Deposit At such time as the Final Design Plan is approved by the Planning and Zoning Commission, and before a building permit is issued for the same project, a compliance deposit shall be required to be deposited with the Town of Avon to provide security for the Owner's full and binding performance to the approved Final Design Plan. The amount of the compliance deposit shall be equal to either: 1) Two percent (2 %) of the valuation cost of construction as submitted in the building permit application, or, 2) A minimum of $5,000 dollars. Additionally, the compliance deposit shall be submitted as cash, certified check, or letter of credit. Time limitations The time limitations contained in these Regulations shall be interpreted as requiring the Commission to conduct a review or make the determinations or decisions required by these Regulations. Failure of the Commission to act within the prescribed time limitations shall be considered as conditional approval for design of the project subject to conformance with all applicable rules and regulations of the Town of Avon. Scheduling The length of the development review process from the acceptance of a complete application by Staff to the actual hearing, shall provide the Town with a minimum review time of 21 working days. Scheduling requirements, timelines, and commitment goals are available in the office of Community Development, and may be updated periodically. A `fast track' review process is available to those plans that are determined by the Community Development Staff to be in compliance with the Town's development standards at the pre - application meeting. Meetings The Commission shall regularly meet on the first and third Tuesdays of each month at the time and location designated on the official meeting agenda. The Chairman may call special meetings of the Commission when deemed necessary. A notice and agenda of each meeting shall be posted in the official posting places of the Town at least 48 hours prior to any meeting of the Commission. All meetings of the Commission shall be open to the public. The printed Record of Proceedings, Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 45 Adopted November 6, 2001 prepared by the Recording Secretary and approved by vote of the Planning & Zoning Commission, shall constitute the only official record of Commission meetings. All records, including proceedings of meetings, applications for review, plans, reports and resolutions shall be maintained in the Community Development Department by the Recording Secretary of the Planning and Zoning Commission. Notification of Action by Commission Within 10 working days following action of the Planning and Zoning Commission, the Commission's decision to approve, conditionally approve, deny approval or continue design review of a project, shall be forwarded to the applicant and his designated agent by first class mail, and posted in a conspicuous manner in the Community Development Department. The decision shall become final if no written appeal is made to the Town Council by any aggrieved person within 30 days following the decision of the Planning and Zoning Commission. Scope of Approval All approvals are site specific. Variations and changes, without Commission approval, are not allowed, except as otherwise provided in these regulations. Appeals A decision of the Planning and Zoning Commission may be appealed to the Town Council by the applicant or any aggrieved person or at the request of the Mayor at any time before the decision becomes final (within 10 days after a hearing). Not more than thirty (3 0) days following the filing of an appeal, the Town Council shall review the action of the Planning and Zoning Commission. The Town Council shall, in writing, confirm, modify or reverse the decision of the Commission within thirty (30) days following the commencement of review. If it deems insufficient information is available to provide the basis for a sound decision, the Town Council may postpone final action for not more than thirty additional days. Failure of the Council to act within thirty additional days shall be deemed a granting of the approval, unless the applicant consents to a time extension. Any decision by the Town Council, which results in disapproval of the Planning and Zoning Commission decision, shall specifically describe the reasons for disapproval. Term of Design Approval Final design approval for a project, as prescribed by these regulations, shall lapse and become void two (2) years following the date of final approval unless a building permit for project construction is issued. If a building permit expires more than 2 years following final design approval, the final design approval also lapses and becomes void. The applicant may apply only once to the Planning and Zoning Commission for approval of a maximum extension of one (1) year for any final design approval. Sketch plan approvals may not be renewed, since they represent only conceptual plans that shall not be considered valid towards a final design submittal beyond six (6) months from the date of approval. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 46 Adopted November 6, 2001 8. Miscellaneous Requlations Application Submittal Checklist Community Development staff shall review all application material submitted for design review to determine whether an applicant has met the requirements outlined above. If the material is found to be adequate, the application and supporting material will be placed on the next available agenda and presented to the Planning and Zoning Commission in accordance with Section 2.30. If the application and supporting material are found to be incomplete or inadequate, the application will not be placed on the agenda. The applicant will be notified of the inadequacies within 7 days of the date application is received. Special Submittal Requirements For Residential, Industrial, and Commercial Projects The Commission may require the submittal of a mass model, samples of proposed exterior building materials and color finishes, charts, graphs and other exhibits to determine impact of proposed project on solar and view corridors of adjacent properties, and any additional studies or information required for a complete review of the application. Models and other special submittals must be available for review by Community Development staff at least one week prior to the Planning & Zoning Commission meeting. Enforcement & Fines The Department of Community Development, the Police Department of the Town of Avon, and the Eagle River Fire Protection District shall be responsible and are both hereby jointly charged with the enforcement of the provisions of these regulations. Fines of $100 per violation of any term or condition of these regulations or any final design approval may be imposed by the Town of Avon. The owner shall pay any fine imposed under these regulations within one week (7 days) after written notice has been received. Amendment These Procedures, Rules and Regulations and any proposed amendments thereto shall be submitted by the Commission to the Town Council who, through publicly held meeting, shall approve the Rules or Amendment and direct their adoption by the Commission or disapprove the proposal with directions for revision and resubmission. Adoption The Commission shall adopt and promulgate these Procedures, Rules and Regulations as well as any Amendments thereto immediately following the approval of these Design Guidelines Procedures, Rules, and Regulations by the Town Council. Severability If any provision of this Regulation or the application thereof to any person or circumstance is held invalid by a court of law, such invalidity should not affect other provisions or applications of this Regulation which can be given effect without the invalid provisions or application and to this end the provisions of this Regulation are declared to be severable. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 47 Adopted November 6, 2001 Appendix 1: Recommended Plant List Evergreen Trees minimum planting height 6 feet Engleman Spruce Picea englemanni Colorado Blue Spruce Picea pungens Not for extremely dry locations Bristlecone Pine Pinus aristata Pines need well drained soils Lodgepole Pine Pinus contorta latifolia Ponderosa Pine Pinus ponderosa scopulorum Rocky Mountain Juniper juniperous scopulorum & var. Available in native form or a wide selection of varieties offering different size, shape and foliage colors Deciduous Trees minimum planting size 2 inch caliper Amur Maple Box -elder Acer ginnala Acer negundo Norway Maple & varieties Acer, platanoides & var, Silver Maple Acer saccharinum European Birch varieties Betula pendula & var. Common Hackberry Russian Olive Green Ash Thornless Honeylocust Varieties: Shademaster, Skyline, Imperial Crabapple varieties Varieties: Hopa, Dolga, Sargents White Poplar Quaking Aspen Cottonwood Species Shubert Chokecherry European Mountain Ash Evergreen Shrubs Pfitzer Juniper Celtis occidentalis Elaeagnus angustifolia Fraxinus pennsylvanica lanceolata Gleditsia triacanthos inermis Malus var. Populus alba Populus tremuloides Populus sp. Species: augustifolia & sargentii Prunus virginiana "Shubert" Sorbus aucuparia Juniperous chinensis "Pfitzeriana" Chinese Juniper varieties Juniperous chinensis var. There are other more desirable landscape trees, but may be useful in difficult growing conditions In protected locations with adequate deep soil moisture Mass plantings not recommended Survival of young trees may be questionable in exposed situations Group plantings only Most dependable large trees Survival of young trees may be questionable in exposed situations minimum planting size: 5 gallon Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 48 Adopted November 6, 2001 Prostrata Juniper Juniperous horizontalis var. Snow cover may be desirable for winter varieties hardiness Tammy Juniper Bird's Nest Spruce Swiss Mountain Pine Mugho Pine Deciduous Shrubs Serviceberry Japanese Barberry varieties Siberian Peashrub Red Osier Dogwood Peking Cotoneaster Winged Euonymus Juniperous sabina tammariscifolial Picea abies nidifomis Pinus mugo Pinus mugo mughus Amelanchier Berberis thunbergi var. Caragana arborescens Cornus stolonifera coloradensis Cotoneaster acutifolia Euonymus alatus minimum planting size: 5 gallon Wintercreeper Euonymus Euonymus vegetus 'Coloratus' Forsythia Common Privet Zabel Honeysuckle Tatarian Honeysuckle Oregon Grape Potentilla varieties Purple- leaved Sand Cherry Nanking Cherry Russian Almond Skunkbush Sumac Alpine Currant Harison's Yellow Rose Redleaf Shrubrose American Elder Ural False Spirea Froebel Spirea Thunberg Spirea Vanhoutte Spirea Snowberry Forsythia intermedia Ligustrum vulgare Lonicera korolkoui "Zabel" Lonicera tatarica Mahonia aquifolium Potentilla var. Prunus cistena Prunus tomentosa Prunus tenella Rhus trilobata Ribes alpinum Rosa harisonii Rosa rubrifolia Sambucus canadensis Sorbaria sorbifolia Spiarea bumalda Spiraea thunbergi Spiraea vanhouttei Symphoricarpos albus laevigatus Hardiness may be questionable in exposed situations Need good mulch or snow cover to insure winter hardiness Hardiness may be questionable in exposed situations Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 49 Adopted November 6, 2001 Indian Currant Coralberry Persian Lilac Common Lilac Wayfaringtree viburnum European Cranberrybush Ground Covers Carpet Bugle Goutweed Snow -in- Summer Leadwart Wintercreeper Euonymus Mint Goldmoss Stonecrop Orange Sedum Two -Row Stonecro White Clover Lawn Grasses Common Kentucky Bluegrass Merion Kentucky Bluegrass Park Kentucky Bluegrass Manhattan Perennial Ryegrass Pennfine Perennial Ryegrass Fescue Varieties: Creeping Red Fescue, Pennlawn. Symphorearpos orbiculatus Syringa laciniata persica Syringa villosa Viburnum lantana Viburnum opulus Ajuga reptans Aegopodium variegatum Cerastium tomentosum Ceratostigma plumbaginofdes Euonymus vegetus "Coloratus" mentha spicata Sedum acre Sedum kamtschaticum Sedum spurium Trifolium repens Poa pratensis Poa pratensis " Merion" Poa pratensis "Park" Lolium perenne "Pennfine" Lolium perenne "Pennfine" Festuca rubra commutata Most ground covers will require snow cover or mulch to insure winter hardiness Most ground covers will require snow cover or mulch to insure winter hardiness Use only as a mix with Kentucky Bluegrass Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 50 Adopted November 6, 2001 APPENDIX 2: Town of Avon Prohibited Noxious Weeds Common Name Scientific Name USDA Code Leafy Spurge Euphorbia esula L. EUES Russian knapweed Centaurea repens L. CERE6, ACRES Diffuse knapweed Centaurea diffusa Lam. CEDI3 Spotted knapweed Centaurea maculosa L. CEMA4 Musk thistle Carduus nutans L. CANUM2 Canada thistle Cirsium arvense (L.) Scop. CIAR4 Plumeless thistle Carduus acanthoides L. CAAC Scotch thistle Onopordum acanthium L. ONAC Houndstongue Cynoglossum officianle L. CYOF Whitetop /Hoary cress Cardaria drabs L. CADR Yellow toadflax Linaria vulgaris P. LIVU2 Dalmatian toadflax Linaria damatica (L.) LIDAM Wild caraway Carum carvi L CACA19 Scentless(Corn) chamomile Anthemis arvensis L. ANAR6 (All above listed weeds are required management in Eagle County through the provisions of The Colorado Weed Management Act, Title 35, Article 5.5 -107 and through Eagle County Resolution No. 2000 -45) Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 51 Adopted November 6, 2001 APPENDIX 3(a): AVO N C O L O R A D O Sketch Desian Plan Aaalication & Checklist SKETCH PLAN Sketch Plan Fee: S Applicant: Mailing address: City: State: Zip: Phone #: Fax #: Cell #: Owner of Property: Mailing Address: City: State: Zip: Phone #: Fax #: Cell #: Lot: Block: Subdivision: Project Street Address: Project Name: ❑ Addition ❑ Single Family ❑ Duplex ❑ Multi- Family ❑ Commercial ❑ Industrial ❑ Other: Please Describe Your Project (arch. style, sq. ft., height, materials, colors, unique features): We (1) represent that all intorniation provided to the Town of Avon in connection with this application as true and con-ect, that we (1) understand the Town of Aeon regulations applicable to tills project, and understand that incomplere submittals iv-ill delay application review. Owner designates Applicant as indicated to act as owner's representative in all application submittals related to this project. Applicant: (Print Name): Date: Owner: (Print Name): Date: Communily Development Department, P.O. Box 975 Avon, CO 51620 (970)7=45 - -40:10 Fax (970)949-5749 Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Adopted November 6, 2001 Page t of 22 Page 52 Pro LoBlock. Subdivision: ❑ Site ❑Floor plans • Topographical survey with signed RLS stamp ❑ Four (4) - 24" x 36" plan sets (all areas over 40% slope shaded) ❑ Eighteen (18)11" x 17" plan sets - one week prior ❑Building elevations (all elevations) to P &Z meetings r ❑North arrow & scale (1 =10' or20') ❑ Proposed grading (solid lines) • Vicinty map with adjacent lots ❑ Existing structures ❑Title block ❑ Driveways, parking and turnarounds • Property lines wlbearings and distances ❑ Streams, if applicable • Setback lines (labeled and dimensioned) ❑ Riparian zone/wetlands, if applicable • Easements (labeled and dimensioned) ❑ Walkways, stairs (dimensions) • Adjacent rights -of -way ❑ Fencing, retaining walls (including specific • Existing topography (dashed lines) materials & colors, T.O.W. & B.O.W. elevations) extended throw h buildin • Current zoning ❑ Off - street parking spaces required and proposed • Number of dwelling units ❑ Area and % of site > 40% slope • Building height allowed and progosed Building Elevations and Floor ❑ Floor plans, dimensions and areas ❑ Natural and finished grades for all elevations (numeric) ❑ Building elevations (labeled) ❑ Numeric elevation of all roof ridgelines Reviewed by: ❑ Complete ❑ Incomplete Date: Community Development Department, P.O. Box 975 Avon, CO 81620 (970)748 -4030 Fax (970)949 -5749 Page 2 of 2 Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 53 Adopted November 6, 2001 Reviewed by: ❑ Complete ❑ Incomplete Date: Community Development Department, P.O. Box 975 Avon, CO 81620 (970)748 -4030 Fax (970)949 -749 Page 2 of 2 Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 55 Adopted November 6, 2001 40 t: Lot: Blocks Subdivision: r • an ❑ Four (4) - 24" x 36" plan sets raphical sun ey with signed RLS stamp ❑ Color board 81/2" x 11" (all areas over 40% slope shaded) ❑ Exterior lighting fixture cut sheets • Floor plans ❑ Eighteen (18) 11 " x 17" plan sets - one week prior • Building elevations (all elevations) to P&Z meetings • Landscape plan ❑ Colored elevations - one week prior to P&Z meetings • Construction stagin lan W I '� - ❑North arrow & scale (1 =10' or 20') ❑ Existing utility lines, manholes, transformers,etc ❑ Vicinty map with adjacent lots ❑ Driveways, parking and turnarounds ❑Title block ❑ Driveway grades (spot elevations) • Property lines w/bearings and distances ❑ Streams, if applicable • Setback lines (labeled and dimensioned) ❑ Riparian zone /wetlands, if applicable • Easements (labeled and dimensioned) ❑ Fire hydrants (location on site or distance and • Adjacent rights -of -way direction from a known point) • Existing topography (dashed lines) ❑ Culverts, ditches, detention, etc. extended through building ❑ Utility service lines (general locations) • Proposed grading (solid lines) ❑ Snow storage area (include sq. footage) • Limits of site disturbance ❑ Walkways, stairs (dimensions) • Building footprint with roof plan and ridgeline ❑ Building and area lighting, by type elevations and driplines (dimensioned to p,l.) U Fencing, retaining walls (including specific • On -site detention structures, if applicable materials & colors, T.O.W. & B.O.W. elevations) • Significant landforms /outcroppings ❑ Trash enclosures ❑ Existing structures ❑ Wall sections (if retaining walls proposed) Site Plan Summary t on Plan sheet) • Current zoning ❑ Garage and surface parking spaces available • Number of dwelling units ❑ Area and % of site > 40% slope • Floor area for each dwelling unit ❑ Area and % of building lot coverage • Total floor area of all units ❑ Area and % of site landscaped • Building height allowed and proposed ❑ Area and % of paved surface • Off -street parking spaces required and proposed Building Elevations ai ' plan • Floor plans, dimensions and areas ❑ Location of address(es) on building or site • Building elevations (labeled) ❑ Location of exterior lighting fixtures, by type • Natural and finished grades for all elevations (numeric) ❑ Materials and colors labeled on elevations • Numeric elevation of all roof ridgelines ❑ Summary table of specific materials and colors • Utility meter locations Landscape Plan:(separate sheet in plan set) • Location of plantings ❑ Plantings summary table • Location of existing shrubs and trees ❑ Sprinkler system type and description ❑ Existin ve etation, general Polution Control Plan:(separate sheet in plan set) ❑ Polution Control Plan that conforms to Appendix 4 of the Design Review Guidelines Reviewed by: ❑ Complete ❑ Incomplete Date: Community Development Department, P.O. Box 975 Avon, CO 81620 (970)748 -4030 Fax (970)949 -749 Page 2 of 2 Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 55 Adopted November 6, 2001 APPENDIX 3(b): Final Design Plan Application & Checklist a of the VALLEY C O L O R A D O FINAL DESIGN Final Design Fee: Applicant: Mailing Address: City: State: Zip: i Phone #: Fax #: Cell #: Owner of Property: Mailing Address: City: State: Zip: Phone #: Fax #: Cell #: Lot: Block: Subdivision: Project Street Address: Project Name: ❑ Addition ❑ Single Family ❑ Duplex ❑ Multi- Family ❑ Commercial ❑ Industrial ❑ Other: Please Describe Your Project (arch. style, sq. ft., height, materials, colors, unique features): We (l) represent that all in forniation provided to the Town of Avon in connection with this application as true and correct, that we (I) understand the Town ofAvon regulations applicable to this project, and understand that incomplete submittals will delay application review. Owner designates Applicant as indicated to act as owner's representative in all application submittals related to this project. Applicant: — (Print Name): Date: Owner: (Print Name): Date: Community Development Department, P.O. Box 975 Avon, CO 81620 (970)743 -4030 Fax (970)949 -5749 Page I of 2 Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 54 Adopted November 6, 2001 Appendix 4: Pollution Control Plan POLLUTION CONTROL PLAN SMALL RESIDENTIAL PROJECTS Temporary Pollution Controls are Required for all construction projects which disturb the existing ground surface. SUBMITTAL REQUIREMENTS Prior to commencement of any construction, a pollution control plan must be submitted to, and approved by, the Town of Avon. Temporary Pollution Con trol Plan for small residential projects shall consist of a plan sheet illustrating the location and type of the temporary pollution controls. The plan shall describe both the management practices and physical controls which will be followed during construction. The Pollution Control Plan shall protect existing drainage strictures and waterways such as culverts and storm sewer inlets from sedimentation. See Figures 4 -1, 4 -2, and 4 -3, for an example of a small residential project Pollution Control Plan. Pollution Control Plan shall be prepared by a Licensed Professional Engineer for Development sites which: 1. Disturb more than'/ acre; 2. Have 50 or more surface parking spaces; or 3. Have slopes greater than 15 %. TEMPORARY POLLUTION CONTROL FACILITIES SRALL BE INSTALLED AND APPROVED PRIOR TO START OF CONSTRUCTION. Poct (4 ire Bnr 97) 400 Benchmark Road 970 - 748 -9000 970 - 999 -W-49 ru:t 970-05 770 1 7TY Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 56 Adopted November 6, 2001 rev NV TES oV.'GL_� A75'r STAKE F -5WXRJ ^REVOUSLY 11VU SAtP' 30twb'a OALFS PLAa7.3 ON GLWTOb'R t-hO ,%9ASRS S T EU P GYE7r _ CR 2'x2' SrAIKf.- t 'A. TO 2' WTO 7:'E L`,-74 0VU. ROW "} WTr1OAL ,rAa5 t, f&cs shall be placed of tha .1ae of a zlop7 oe av tha cortoU and kr a now with ands UghJy oDalt,aq the edpoant balms . B.-Jes &W/ be security anchored ,n Race by etthor- two ,sfehes ar rebus driven thravgh the bole. The ,first slake S-i aar�6 beta Mat be de em f-awaref iWa prcviwzry IoiW bai`o at on or& to force the befes togather, ,I Oa= to r rrmZ7 .0 plcca wrIN xgaatiarr is fvt(y aseabtrslard an upgrodient area., ¢, Pay bates shall be con"luously ,ma:' -Wted duretg sit* cntstrucffat etc:Wh" S Bales Mcd be rrmowd whint May hoya served trek vzok -mass rd os not to Wack or kmpedo stami Sow rx drainage. NA Y &ALE INSULL49MW MASTER DFAINACiE .STu10;1 TO W. 1 OF A VON FACLF COUNTY, CDLOPA-1-10 • - - 93026E CRAMHc H2' 4-2 Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 57 Adopted November 6, 2001 L LIC A r lf.�' L"K"WiSMEAU UAW C-,O- C;PAaM EX/1UPLE' - RESIDENVAL POLLUPON C MA S TER DR,4 INA L;E- SW%D r TIO l`V/V CV-7 A, VC,11/ A oGL r- . cbwn,, cozapAoc qo ULM -1671 -- I - I t y A Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 58 Adopted November 6, 2001 CL 0:111 AIC6H (:�P6YjV11V ~ is- (41N)m���� _ 4o��m�7 -j- ~--`- ' M1711-0 "LJA ullf&.#iRaroEARTH Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 59 Adopted November 0.2UO1 Appendix 5: Stormwater Control Plan Introduction The objective of this manual is to provide design professionals with the Town of Avon's drainage requirements. Drainage systems shall be designed to protect public and private property, minimize maintenance costs and preserve the appearance of roadways and property. This manual outlines the basic engineering procedures to be used to design and construct stormwater structures and systems. Designers should use this section as a guideline when preparing drainage plans and reports for the Town of Avon. If designers feel that the methods outlined in this section are not applicable, another method may be used if approved by the Town. Design Standards — Runoff Drainage structures and facilities in the Town of Avon shall be designed to handle the 25 -year rainfall storm event. Facilities shall also be designed so there will be no major structural damage or loss of life from the 100 -year storm event. Drainage structures beneath or adjacent to arterial (i.e. I -70 and U.S. Highway 6) and collector streets (i.e. Beaver Creek Blvd., Nottingham, Avon and Metcalf Roads) shall be designed for the 100 -year rainfall event. Developers of lots adjacent to the Metcalf Gulch, Buck Creek and Swift Gulch (see plan sheets) drainage pathways are required to maintain the drainage pathway to pass the 100 -year storm. The Town of Avon may require additional drainage requirements for any site which it believes has special conditions. Snow Melt The addition of snow melt runoff is required for stormwater control only. The 25 -year snow melt runoff event shall be used. All other drainage designs can disregard the addition of runoff from snow melt. Stormwater Control A stormwater control plan and facility is required for sites with: 1. 25,000 square feet of impervious surface, or 2. Having fifty or more surface parking spaces. Sites shall be designed so the 25 -year developed flow rates do not exceed the historic. Detention facilities should be designed for the major and minor storm event. The major event will be the 100 - year storm and the minor event is the 25 -year storm. The facility shall be sized to store volume created from the difference in historic and developed 25 -year storm event. The release rate from the facility shall not exceed the 25 -year historic flow rate. The facility shall have an emergency spillway or additional outlet for the 100 -year storm. Estimating Runoff Several methods are available for estimating runoff. Designers should select a method based on the size of the drainage area and the output information desired. The Town of Avon will accept the following methods: 1. Rational Method (sites less than 5 acres) 2. Technical Release 55 (TR -55) Another method may be used provided it is approved in advance by the Town of Avon. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 60 Adopted November 6, 2001 Rational Method The rational method may be used to size storm sewers, channels, and other drainage structures which handle runoff from drainage areas less than 5 acres. This method should not be used for routing stormwater through a basin or for developing a runoff hydrograph. Drainage basin characteristics should be fairly homogeneous. Figure 3 -1 illustrates the rainfall intensity- duration curve to be used in the Town of Avon. Technical Release 55 (TR -55) TR -55 (210- VI -55, Second Edition, June 1986) is a method developed by the USDA -Soil Conservation Service to estimate runoff. The Soil Conservation Service has supplemented the TR -55 manual for Colorado to handle its unique drainage conditions. "Procedures for Determining Peak Flows in Colorado" is in the SCS manual to be used when estimating runoff with TR -55 in Colorado. There are two methods discussed in TR -55, Peak Discharge and Tabular. Designers need to decide which method is the most appropriate. The Peak Discharge Method is usually used for small homogenous watersheds and the Tabular Method is used when a watershed is divided into subareas and a hydrograph is needed. Twenty -four (24) hour rainfall amounts to be used in Worksheet 2 of TR -55 are listed in Table 3 -1. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 61 Adopted November 6, 2001 RAINFALL IN 1M51 TY- OURA 77CW CI R VE FOP A VOIV +,s {r S l ,? OPA11''4 6E S JVO Y r'V 11'71 OF A VO N , SOLE COOi'V T Y., COL ORALCO f +iautr riaw 9.3026E G +Yrt pl: 'f M DAM :{U'MH: Mtlt 3-1 Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 62 Adopted November 6, 2001 TABLE 3 -1 24 -HR RAINFALL AMOUNTS Frequency 24 Hr Rainfall (P) 2 — year 1.3 — inches 5 — year 1.6 — inches 10 — year 1.9 — inches 25 — year 2.3 — inches 50 — year 2.6 — inches 100 — year 2.8 — inches Estimating Snow Melt The snow melt runoff coefficient to be used for the 25 -year event is 0.067 cfs /acre. This coefficient is needed only for stormwater control facilities. Stormwater Control Stormwater control is required for sites with 25,000 square feet of impervious surface or fifty or more surface parking spaces. Stormwater controls are implemented to keep post- development flow rates from exceeding historic. This effectively protects downstream properties from increased runoff which generally occurs when the amount of the impervious surface increases. Existing drainage systems are to be designed to handle a 25 -year storm event; therefore stormwater control facilities shall be designed so the historic 25 -hear flow is not exceeded. The facility does not need to detain any runoff until the historic 25 -year runoff rate is exceeded. Stormwater control facilities shall be designed for the major and minor storm event. The major event will be the 100 -year storm and the minor event is the 25 -year storm. The facility shall have an emergency spillway or additional outlet for the 100 -year storm. The facility shall be sized to store volume created from the difference in historic and developed 25 -year storm event. The release rate from the facility shall not exceed the 25 -year historic flow rate. Design Methods One of the most widely used procedures for determining storage volume is the Storage- Indication Method. This flow routing method consists of a trial and error process based upon the Continuity Equation. The SCS National Engineering Handbook, Section 4, Chapter 17, provides an in -depth explanation of the subject of flood routing. A simple but less accurate method for estimating detention storage is the Graphical Storage Method. This method was developed by SCS and is explained in the SCS TR -55 Manual. This method is particularly suited for small detention basin designs, preliminary estimates of storage requirements, and for estimating the required size of temporary facilities. If using the Graphical Storage Method, failure of the structure must not endanger or result in a loss of life and a calculated storage volume error of +/ -25% must be tolerable. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 63 Adopted November 6, 2001 Open Channel Flow Developers shall design and construct new or modify existing channels to adequately handle the required design storm. Manning's Equation (V= 1.49/nR2/3 S 1/2) and the Continuity Equation (Q =VA) should be used to calculate the velocity and flow capacity of an open channel. After the velocity and capacity of a channel has been calculated, it should be compared to the permissible velocity and maximum capacity of a channel. If the anticipated velocity and capacity is less than the permissible velocity and maximum capacity, then the channel is considered to be adequate. The maximum permissible velocity of a grass lined channel shall be 5 feet per second. Channel linings are required if either the capacity or velocity of a grass -lined channel is not adequate. Channel linings which stabilize a channel by preventing erosion and increasing capacity must be properly designed for the anticipated capacity and velocity. See Figure 3 -2. Channel linings are usually classified as either rigid (concrete, asphalt) or flexible (Rock rip rap). Rigid channels can handle greater capacities and permissible velocities. Flexible channel linings are less expensive, safer for roadside, self - healing, filter contaminants and permit infiltration, but have a lower flow capacity and may experience erosion damage. Culverts and Storm Sewers All culverts and storm sewers in the Town of Avon shall be sized to handle the 25 -year storm unless it is beneath or adjacent to an arterial or collector street. Culverts and storm sewers beneath or adjacent to an arterial or collector street must be designed for the 100 -year storm. Facilities shall be designed so there will be no major structural damage or loss of life from the 100 -year runoff event. Designers shall assume developed conditions for any adjacent undeveloped lots. For maintenance reasons, no culvert within the Town of Avon should be smaller than 18 inches in diameter (21" x 15" arch culverts are acceptable). To increase the hydraulic efficiency of a culvert (preventing scour at the inlet and undermining at the outlet) finished ends may be required. Finished ends (in the order of greatest hydraulic efficiency) include headwalls, flared end sections, mitered ends, and rip rap. Headwalls can be concrete or a combination of textured concrete and masonry so they not only increase hydraulic efficiency but are aesthetically pleasing. Designers should check the inlet and outlet control conditions. The maximum allowable headwater depth from the 100 -year storm shall be 1.5 times the culvert diameter, or 1.5 times the culvert rise dimension for shapes other than round. If approved by the Town of Avon, it may be satisfactory to allow excess water from the 100 -year storm to sheet flow across a roadway provided minimal erosion and property damage will result. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 64 Adopted November 6, 2001 S1 13,14E 'OfEIGHT, IN PQU,40'5 3D7 Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 65 Adopted November 6, 2001 0 SP.HERIC-41- DIAMETER OF STIDNr, IN FEET A(Ur4, re.rir will ­f"Oul FC - - C, . u I ,. !,, D L X1 :, rt. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 65 Adopted November 6, 2001 Minimum and maximum velocity must be considered when designing culverts. A minimum velocity of 3 fps is recommended for a pipe to be self - cleaning. The maximum velocity is dictated by the outlet channel conditions. An outlet velocity less than 5 fps is recommended for grassed lined channels with minimal erosion protection. Outlet velocity shall never exceed 12 fps. Culverts shall be designed to permit free unobstructed passage of debris and silt, or provide for their deflection and/or collection at a point upstream. If a battery of pipes is required, a clear space of one -half the pipe diameter (one foot minimum, four foot maximum) must be provided between pipes. Cleanout access shall be provided at least every 200 feet for pipes up to 24 inches in diameter and every 400 feet for pipes larger than 24 inches. Cleanouts are also required at all bends in all pipe sizes. Submittal Requirements A stormwater control plan is required for projects which have more than 25,000 square feet of impervious surface or fifty surface parking spaces. The stormwater control plan must be prepared by a professional engineer licensed in the State of Colorado. The Town of Avon may require a stormwater control plan for any site which it feels has special conditions that warrant investigation. The stormwater control plan shall consist of a plan sheet and report which evaluate the existing and proposed conditions. The required pollution control plan for the site may be combined with the stormwater control plan in a single report. The stormwater control plan shall contain the following: Plan Sheet The plan sheet shall include the following: 1. Topographic map (not less than 1 " =40') of the site which shows existing and proposed drainage patterns (i.e. grading plan). Basin vicinity map (i.e. USGS quad) which shows the limits of the tributary area(s). Location of proposed streets, driveways, buildings, homes, Parking areas and other structures. 2. Location, size, slope, and capacity of all drainage structures (i.e. culverts, storm sewers, drainage channels, inlets, etc.). 3. Expected peak discharge at critical locations (i.e. drainage structures, outfalls, etc.). 4. Sufficient details for construction. Narrative The narrative shall include the following: 1. A general description of the project. 2. A description of the existing and proposed land uses. 3. Calculation method with a listing and justification of all coefficients and assumptions used in the calculations. (All calculations shall be attached to the narrative as an Appendix). 4. A description of existing, proposed and tributary drainage patterns. 5. A summary of the historic and developed runoff rates and volumes. 6. Description of existing and proposed drainage structures (detention pond, culverts, etc.). Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 66 Adopted November 6, 2001 Appendix 6: Example Color Board 5 T 1 0 COLOR BOARD: see -o '.her -,kip for,doscripLons Exterior 1-2146 - 131rck 4 Exieriar —Siding .42: SWD7,): Exderior Trim: Roofil•g, Extarior Building kla[erials Palette: ,'b fesemb!e altached photo) t RECEIVED APR 0.,'1 Z901 Cc "l -'unty Devoic.-II-np-l[ &"_hmrrd S WO % 1 -.9 r Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 67 Adopted November 6, 2001 - S T D I'0 pa bay 4525 • r Q01-OR EtQAkQ: Wothet 91d. r oo6o r Fxtarler BuildIng IVIOff 49: Wildfta Lot 46 - i�t;k 4 ExleriorSiiding 01: Exteror Uing 92: Stu= Exterior Trim: Tee: Rooting; Stone; Colored Metal Clad Windows, Cedar Bard & 80em Sh cairn William: Wneykane Cedar Clapboard Siding Sherwin 'WEtlia w Wtea'WNW Porter Paints VAita Umber (medium Jexlure to be provided) Cedar SherwIn Will; 3,ns. Bwch=od St*kred Uncrete Match WWreO Stone ,Yens Cv.nirq Asphalt Sr- ingles Desert Tan w issir. Nens Corning Cultured Stone Bucks Ommy Fielftbrie E:agk orequWlent FI re Engine Rod Garage Coors- Ceder T &C & Planliing wf Bewbwood Stain Exi0or lighting F ixtu res. A: Arurniflum Pendant %,d shaded g lass 8: Atumimm Pendant wJ Shaded glass C: Arroyo Cral'sm an Evergreen D: Arroyo Crahsman Ew�reen 't�ra9rnaurn ► the T it of A� E; Arroyo Craftsman Berkeley PQ hnlnq and W", Note: All Extedw Li hi Fixtures Obscured glass 13V - Vft t fd Micm- Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 68 Adopted November 6, 2001 Appendix 7: Example Site Plan r j ,, �{ / :, +� I /�' Fes/ _.' - /''` �+:r _ _ � ( p� ` '� w� • • I f x.13 Oe Aw e f ! 7 , lei, it } r, + y 1� i 1 oil Y Note: This example is not intended to suggest building design, site grading, site design, or preferences of the Town. It is merely to demonstrate the minimum level of detail required for final design site plans. Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 69 Adopted November 6, 2001 Appendix 8: Application and Design Review Fees Following is the schedule of fees for Design Review applications in the Town of Avon. These fees may be updated periodically. Please check with the Community Development Department to ensure you have the most recent fee schedule. Residential 1 — 3 Units Up to 3,500 square feet unit size Over 3,500 square feet unit size 4 — 9 Units $350 $500 $750 10 — 20 Units $1,000 21 — 40 Units $1,500 41 — 60 Units $2,000 6 — 100 Units $2,500 Over 100 Units $3,000 (Residential units within a mixed use project are assessed according to the Commercial fee schedule below.) Over 50,000 sf. Commercial, Industrial, and Mixed Use Up to 1,000 square feet (sf) $200 1,000 — 2,499 sf $500 2,500 — 4,599 sf $750 5,000 — 9,999 sf $1,000 10,000 — 19,999 sf $1,500 20,000 — 49,999 sf $2,000 Over 50,000 sf. $2,500 Minor Project or Modification to Final Design $75 Non - approved Modification to Final Design 3 X fee Extension of Final Design Approval '/z fee Town of Avon Residential, Commercial, and Industrial Design Review Guidelines Page 70 Adopted November 6, 2001