PZC Packet 030111Memorandum
To The Planning and Zoning Commission
Fr Sally Vecchio, Community Development Dir.
Date February 24, 2011
RE Work Session 3: Overview of the Avon Development Code, Chapter 7.28 Development Standards
This is the third PZC work session reviewing the recently adopted Avon Development Code (the Code). This
meeting will focus on the Development Standards of the Code.
Broken into nine (9) categories, this chapter of the Code provides specific criteria for design and
development in the Town. Many of the standards from the Avon Design Guidelines were codified in this
chapter, along with new standards intended to implement the Town's land use policies, including: a more
pedestrian oriented community, protection of our natural resources, and attractive well-designed buildings.
The standards apply to all development in the town.
Staff will give a brief over review of each section of the Code, while identifying the new provisions. An
outline of the nine development standards included in Chapter 7.28 is attached, and will be used to guide the
discussion on Tuesday night.
The Checklists
The Checklists (attached) summarize each section and subsection of the Development Standards that will
need to be addressed in a development plan application. There are 5 different checklists, depending on the
proposed development (single-family/duplex, town homes/multifamily, mixed-use, natural resource, and
alternative equivalent compliance).
The Checklists are intended to be used by designers in preparing development plans, and by staff and PZC
while reviewing applications to ensure compliance with town standards for transportation access and
circulation, landscaping, parking, architectural design and areas subject to natural resources.
PZC WORKSHOP 3 — AVON DEVELOPMENT CODE
TOPIC: Chapter 7.28 - Development Standards
§7.28.020 Parking and Loading
Existing section with new additions designed to reduce impact of parking lots, and codifying the town's driveway
requirements.
• Standards and illustrations for parking stall dimensions (no change)
• Off-street parking requirements (min changes from old code)
• 125% increase in parking max (with minor exception by Director)
• Mixed-use reduction (no change)
• On street parking may be included in calculations (new)
• Public Parking Districts (no change)
• Bike Facilities for developments with > 25 parking spaces (new)
• Design/Maintenance Requirements (new)
o Includes snow storage requirements
• Off -Street Loading (no change)
§ 7.28.030 Access Driveway requirements
Existing standards and new standards codified
• Mountain Terrain — new requirements, PZC approval for modifications
• Court Driveways (new)
• Drive-through Standards (new)
§7.28.040 Mobility and Connectivity (AEC Available)
New section implements planning policies supporting pedestrian connectivity, reducing dependency on vehicle,
improving transit.
• Bike and Pedestrian Paths
• Vehicle Circulation — Internal Streets
• External Streets and Sidewalks
§7.28.050 Landscaping (AEC Available)
Existing section with new standards for parking lots, buffering, maintenance and plant quantities.
• Landscaped Area (no change)
• Buffers between non-residential and residential uses (new)
• Landscaped Units (new)
o Based on average unit counts approved by PZC
• Parking Lot Landscaping (from Design Guidelines)
• Landscape Standards (new)
• Plant List (no change)
• Noxious Vegetation (no change, reference to title 8 AMC)
• Irrigation and Watering Requirements (from Design Guidelines)
• Revegation Requirements (from Design Guidelines)
21 Page
§7.28.060 Screening (AEC Available)
New section intended to screen certain uses from public view
• Mechanical Equipment
• Loading and Service Areas
• Outdoor Storage Yards
• Dumpsters
• Materials and Design
§7.28.070 Retaining Walls (AEC Available)
New section intended to set limitation on size and material of retaining walls
• Height and Material (from Design Guidelines)
§7.28.080 Fences (AEC Available)
Existing standards codified from the Design Guidelines
§7.28.090 Design Standards (AEC Available)
Existing standards from the Design Guidelines and new standards to implement Comprehensive Plan
recommendations.
1. General Applicable Design Standards
• Site disturbance envelopes (new)
• Site design/ building orientation (new)
• Materials and colors (no change)
• Roof overhangs and materials
• Weather protection for pedestrian areas
2. Generally Applicable Residential Standards
3. Design Standards for Wildridge (new)
4. SF and Duplex Standards in all other subdivision
5. Townhouse Design Standards
6. Multifamily Design Standards
7. Residential Parking Locations and Layout
8. SF and Duplex Garages
9. Mixed Use and Non -Residential Standards (most from Design Guidelines and District Plans)
§7.28.100 Natural Resource Protection
New section with standards codified from the Design Guidelines, and Comprehensive Plan.
1. Steep Slopes
2. Streams, River, Waterbodies, Wetlands
3. Grading, Erosion Preventions and Sedimentation Control
4. Flood Damage Prevention
5. Geological Hazard Areas
6. Scenic Views (reserved)
7. Alternative Energy Systems (solar and wind)
31 E' a g e
DEVELOPMENT REVIEW CHECKLISTS — SINGLE-FAMILY & DUPLEX
ZONE DISTRICT STANDARDS
Date
Zone District:
Lot:
Subdivision:
This checklist is for the sole purpose of assisting the applicant in preparation of a development plan application. The applicant should refer to the
Avon Development Code and Application Submittal Requirements to complete a development plan application. This checklist is not an official part
of the Avon Development Code and should in no way be considered a replacement for the Code or instructions contained with the application.
Code
i Section
7.20
Code Requirement
Minimum Lot Size
Comply
Not
.Applicable
Not
Staff Comments
7.20
Minimum Lot Width
adequate widths, sight lines and appropriate
7.20
Maximum Lot Coverage
lighting.
7.20
Minimum Landscape Area
Public sidewalks are located along perimeter
§ 7.20
Building Setbacks
7.28.040(e)(3)
streets.
§ 7.20
Max Building Height
7.20
Max Number of Dwelling Units
§ 7.20.100
0 Deed Restricted Units
7.24
Use Permitted
the princi al buildings entrances.
MOBILITY AND CONNECTIVITY - Bicvcle and Pedestrian Paths
Bicycle/pedestrian paths are designed with
7.28.040(e)
adequate widths, sight lines and appropriate
lighting.
Public sidewalks are located along perimeter
7.28.040(e)(3)
streets.
There a continuous, internal pedestrian walkway
7.28.040(e)(4)
provided from the perimeter public sidewalks to
the princi al buildings entrances.
7.28.040(e)(5)
Adeauate bike Darkina facilities are Drovided.
7.28.040(e)(6)
Bicycle paths constructed in public right of way
CODE SECTION•D
• NOCOMMENTS
The proposed new subdivision street circulation
meet TOA Standards.
7.28.040(f)(2)(i)
plan provides multiple connections to the
7.28.040(e)(7)
Bicycle paths in private communities will be
existing Town street network.
maintained by the HOA.
A cul de sac or dead-end street has been used
Bicycle/pedestrian paths connect all adjacent
7.28.040(f)(2)(ii)(A)
due constraints such as existing topo, natural
7.28.040(e)(8)
developments, neighborhoods, and typical
features or vehicle safety.
destinations (schools, public trails, rec facilities,
A cul-de sac is not proposed for
etc .
7.28.040(f)(2)(ii)(A)
commercial/industrial uses.
7.28.040(e)(9)
Location of paths takes into consideration
T
All permanent dead end streets have been
existing travel patterns.
7.28.040(f)(2)(ii)(B)
7.28.040(e)(10)
Sidewalks are not located in areas prone to ice.
MOBILITY AND CONNECTIVITY
- Vehicle Circulation
CODE SECTION•D
• NOCOMMENTS
The proposed new subdivision street circulation
7.28.040(f)(2)(i)
plan provides multiple connections to the
existing Town street network.
A cul de sac or dead-end street has been used
7.28.040(f)(2)(ii)(A)
due constraints such as existing topo, natural
features or vehicle safety.
A cul-de sac is not proposed for
7.28.040(f)(2)(ii)(A)
commercial/industrial uses.
T
All permanent dead end streets have been
7.28.040(f)(2)(ii)(B)
designed as -cul de -sacs and extend no further
than 1000 linear feet.
7.28.040(f)(2)(ii)(C)
Proposed cul-de-sac conforms to Fire Code and
has been approved by Fire District.
7.28.040(f)(2)(ii)(D)
No half streets are proposed.
A pedestrian access easement has been
7.28.040(f)(2)(ii)(E)
provided (10 ft wide), between the cul-de-sac
LL
and the closest adjacent street or sidewalk.
The arrangement of streets in a development
provide for the alignment and continuation of
7.28.040(f)(3)(i)
existing of proposed streets. Traffic calming
measures shall be integrated into the
development to mitigate the impact of future
"cut -through) traffic.
LANDSCAPE STANDARDS
CODE SECTION•.
Street ROW shall extend to or along adjoining
NOCOMMENTS
7.28.050(d)
property boundaries so that a roadway
7.28.040(f)(3)(ii)
connection of street stub shall be provided for
ever 1,500 feet.
7.28.050(e)
Street and sidewalk connections shall be made
7.28.040(f)(3)(iii)
between neighborhood commercial and
residential.
LANDSCAPE STANDARDS
CODE SECTION•.
•
NOCOMMENTS
7.28.050(d)
If required does the landscape buffer meet code
requirements.
Does the application provide the necessary
7.28.050(e)
Landscape Units at a minimum of 1 unit per 50
square feet of landscaped area.
Is perimeter parking lot landscaping provided at
7.28.050(f)(1)
a minimum width of 6 feet and 1.2 landscape
units per lineal foot.
Is an internal landscape strip provided for every
7.28.050(f)(2)
other row of double row parking, when more
than 50 spaces are provided.
7.28.050(f)(4)
Does the internal landscaping island meet the
code's design requirements.
7.28.050(f)(5)
Does the internal landscaping strip meet the
code's design requirements.
Parking Lot Landscaping in TC District.
7.28.050(f)(6)
Does the proposed landscaping meet the code
requirements.
7.28.050(g)
Does the landscape plan respond to minimum
sight distance triangle requirements.
7.28.050(h)(1)
Existing native vegetation and mature trees
I
I
have been preserved.
No trees or vegetation have been removed
(except for noxious or non-native) outside
7.28.050(h)(1)(i)
designated site disturbance areas on lots
greater than '/2 acre in the RL, RD and RM zone
districts.
All native landscaping has been kept in its
7.28.050(h)(1)(iii)
native state.
7.28.050(h)(1)(iv)
Significant Trees and vegetation that have been
•
N/A
AEC
STAFF COMMENTS
7.28.060(b)(1)
removed from the site has been replaced.
7.28.050(h)(1)(iv)(C)
The location of Protective Construction Fencing
has been identified on the plans.
7.28.050(h)(2)
Proposed plant materials' have been specified
on the plans
7.28.050(h)(3)
Noxious Vegetation has been identified for
properties
removal
Temporary installations of gas/oil tanks are
7.28.050(h)(4)
Irrigation Plan is included on the Landscape
7.28.060(b)(4)
screened from public ROW and/or neighboring
Plan.
properties.
SCREENING STANDARDS
CODE SECTION•.
•
N/A
AEC
STAFF COMMENTS
7.28.060(b)(1)
All outdoor refuse and recycling receptacles are
screened
All antennas are screened from view from an
7.28.060(b)(2)
public ROW or neighboring property
Satellite dishes are screened from neighboring
7.28.060(b)(3)
properties
Temporary installations of gas/oil tanks are
7.28.060(b)(4)
screened from public ROW and/or neighboring
properties.
Mechanical equipment is screened from public
7.28.060(d)
ROW and/or neighboring properties by a
parapet wall or similar feature that is an integral
part of the building's architectural design.
Load and service areas are in the rear, side or
7.28.060(e)
inside of building, not visible from public ROW
or adjacent residential uses.
7.28.060(f)
Outdoor storage areas are screen with
approved materials.
7.28.060(g)
Shopping carts are stored inside the building.
Shopping cart corrals are not plastic.
Dumpsters are screened with 6 fit masonry wall
7.28.060(h)
or wooden fence not visible for public ROW or
nei hboring property.
7.28.060(i)(1)
Plant materials are used to screen utility boxes
7.28.060(i)(2) No fence, wall or hedge is tall than 6 ft
RETAINING WALLS
CODE SECTION•.
• NOCOMMENTS
7.28.070(b)(1)
Retaining walls are utilized because finished
Wildridge fence does not delineate the
grades cannot meet Code standards
property boundaries, is less than 4 ft in height,
Walls over 4 ft high are designed with a series of
split rail with no more than 2 rails, does not
7.28.070(b)(2)
terracing. The width of terrace is at least 5 ft.
delineate an area > 2,000 sf, and does not
Retaining walls over 7 ft in height have been
7.28.080(b)(1)
negatively affect wildlife migration. Multi -family
7.28.070(b)(3)
approved by PZC
fence is integrated into overall design of the
7.28.070(b)(4)
Wall material is compatible with site and
property. Duplex fence received approval from
buildings on site
adjoining property and fence is integrated into
Walls over 4 ft high have been structurally
overall design of the property.
7.28.070(b)(5)
designed and certified by Colo licensed
Walls and fences are architecturally compatible
engineer and approved by Town Engineer.
7.28.080(b)(2)(i)
with the style, materials, color of primary
FENCES
CODE SECTION•.
•COMMENTS
Wildridge fence does not delineate the
property boundaries, is less than 4 ft in height,
split rail with no more than 2 rails, does not
delineate an area > 2,000 sf, and does not
7.28.080(b)(1)
negatively affect wildlife migration. Multi -family
fence is integrated into overall design of the
property. Duplex fence received approval from
adjoining property and fence is integrated into
overall design of the property.
Walls and fences are architecturally compatible
7.28.080(b)(2)(i)
with the style, materials, color of primary
building(s).
Fences and walls are not greater than 50 ft in
7.28.080(b)(2)(i)
solid, unbroken expanse length.
7.28.080(b)(2)(ii)(A)
Fences material is compliant with Code
7.28.080(b)(2)(ii)(B)
Fences in front yard is at least 50% open.
Material has been approved by Director.
7.28.080(b)(2)(ii)(C)
Solid fences have been designed to meet
Building Code wind design criteria.
7.28.080(b)(2)(iii) Security fencing (razor , barbed wire or electric
charge) are prohibited.
7.28.080(b)(2)(iv) Fence conforms to height limits.
RESIDENTIAL DESIGN STANDARDS - Wildridge Subdivision
CODE SECTION•D• NOCOMMENTS
7.28.090(e)(2) Roofs have 4:12 pitch or greater or have
reduced building height to 30 ft.
Building has street -facing architectural details
7.28.090(e)(3) and elements which provide human scale to
the facade.
RESIDENTIAL DESIGN STANDARDS -Single Family & Duplex Standards
CODE SECTION•D• NOCOMMENTS
—
All Other Subdivisions
7.28.090(f)(1)
Entry features and front doors to unit are
CODE SECTION•.
•
NOCOMMENTS
dominating elements facing the street.
Duplex building relates to the surrounding area
shall either recess behind the front fagade of
7.28.090(f)(2)
by providing variations in height and massing,
the dwelling portion of the structure or a front
respecting scale/height of adjacent home and
porch, or recess beneath a second floor bay.
articulating front fagade.
Side -loaded garages shall provide windows or
RESIDENTIAL PARKING
LOCATION AND LAYOUT - Single
Family and Duplex
CODE SECTION•.
•
NOCOMMENTS
Front -loading (street -oriented) garage doors
7.28.090(i)(2)(i)
shall either recess behind the front fagade of
the dwelling portion of the structure or a front
porch, or recess beneath a second floor bay.
Side -loaded garages shall provide windows or
other architectural details that are consistent
7.28.090(i)(2)(ii)
with or complement the features of the living
portion of the dwelling on the side of the
garage facin the street.
The use of alley or side -loaded garages, or the
7.28.090(i)(2)(iii)
use of a combination of these garage
orientations is required where feasible.
0
DEVELOPMENT REVIEW CHECKLISTS — MULTI -FAMILY RESIDENTIAL
ZONE DISTRICT STANDARDS
Date
Zone District:
Lot:
Subdivision:
This checklist is for the sole purpose of assisting the applicant in preparation of a development plan application. The applicant should refer to the
Avon Development Code and Application Submittal Requirements to complete a development plan application. This checklist is not an official part
of the Avon Development Code and should in no way be considered a replacement for the Code or instructions contained with the application.
Code
i Section
7.20
Code Requirement
Minimum Lot Size
Comply
Not
.Applicable
Not
Staff Comments
7.20
Minimum Lot Width
NO
NIA
AEC
STAFF COMMENTS
7.20
Maximum Lot Coverage
Bicycle/pedestrian paths are designed with
7.20
Minimum Landscape Area
7.28.040(e)
adequate widths, sight lines and appropriate
§ 7.20
Building Setbacks
lighting.
§ 7.20
Max Building Height
7.20
Max Number of Dwelling Units
7.28.040(e)(3)
§ 7.20.100
0 Deed Restricted Units
7.24
Use Permitted
MOBILITY AND CONNECTIVITY
- Bicycle and Pedestrian Paths
YES
NO
NIA
AEC
STAFF COMMENTS
CODE SECTION•.REQUIREMENT
Bicycle/pedestrian paths are designed with
7.28.040(e)
adequate widths, sight lines and appropriate
lighting.
Public sidewalks are located along perimeter
7.28.040(e)(3)
streets.
There a continuous, internal pedestrian walkway
7.28.040(e)(4)
provided from the perimeter public sidewalks to
the princi al buildings entrances.
7.28.040(e)(5)
Adequate bike parking facilities are provided.
7.28.040(e)(6)
Bicycle paths constructed in public right of way
meet TOA Standards.
7.28.040(e)(7)
Bicycle paths in private communities will be
CODE SECTION•D
• NOCOMMENTS
The proposed new subdivision street circulation
maintained by the HOA.
7.28.040(f)(2)(i)
plan provides multiple connections to the
Bicycle/pedestrian paths connect all adjacent
existing Town street network.
7.28.040(e)(8)
developments, neighborhoods, and typical
A cul de sac or dead-end street has been used
destinations (schools, public trails, rec facilities,
7.28.040(f)(2)(ii)(A)
due constraints such as existing topo, natural
etc .
features or vehicle safety.
7.28.040(e)(9)
Location of paths takes into consideration
A cul-de sac is not proposed for
existing travel patterns.
7.28.040(f)(2)(ii)(A)
commercial/industrial uses.
7.28.040(e)(1 0
Sidewalks are not located in areas prone to ice.
MOBILITY AND CONNECTIVITY
- Vehicle Circulation
CODE SECTION•D
• NOCOMMENTS
The proposed new subdivision street circulation
7.28.040(f)(2)(i)
plan provides multiple connections to the
existing Town street network.
A cul de sac or dead-end street has been used
7.28.040(f)(2)(ii)(A)
due constraints such as existing topo, natural
features or vehicle safety.
A cul-de sac is not proposed for
7.28.040(f)(2)(ii)(A)
commercial/industrial uses.
All permanent dead end streets have been
7.28.040(f)(2)(ii)(B)
designed as -cul de -sacs and extend no further
than 1000 linear feet.
7.28.040(f)(2)(ii)(C)
Proposed cul-de-sac conforms to Fire Code and
has been approved by Fire District.
Sir
7.28.040 f 2 ii D
No half streets are proposed.
A pedestrian access easement has been
7.28.040(f)(2)(ii)(E)
provided (10 ft wide), between the cul-de-sac
and the closest adjacent street or sidewalk.
The arrangement of streets in a development
provide for the alignment and continuation of
7.28.040(f)(3)(i)
existing of proposed streets. Traffic calming
measures shall be integrated into the
development to mitigate the impact of future
"cut -through) traffic.
LANDSCAPE STANDARDS
CODE SECTION•.
Street ROW shall extend to or along adjoining
NOCOMMENTS
7.28.050(d)
property boundaries so that a roadway
7.28.040(f)(3)(ii)
connection of street stub shall be provided for
ever 1,500 feet.
7.28.050(e)
Street and sidewalk connections shall be made
7.28.040(f)(3)(iii)
between neighborhood commercial and
residential.
LANDSCAPE STANDARDS
CODE SECTION•.
•
NOCOMMENTS
7.28.050(d)
If required does the landscape buffer meet code
requirements.
Does the application provide the necessary
7.28.050(e)
Landscape Units at a minimum of 1 unit per 50
square feet of landscaped area.
Is perimeter parking lot landscaping provided at
7.28.050(f)(1)
a minimum width of 6 feet and 1.2 landscape
units per lineal foot.
Is an internal landscape strip provided for every
7.28.050(f)(2)
other row of double row parking, when more
than 50 spaces are provided.
7.28.050(f)(4)
Does the internal landscaping island meet the
code's design requirements.
7.28.050(f)(5)
Does the internal landscaping strip meet the
code's design requirements.
Parking Lot Landscaping in TC District.
7.28.050(f)(6)
Does the proposed landscaping meet the code
requirements.
7.28.050(g)
Does the landscape plan respond to minimum
sight distance triangle requirements.
7.28.050(h)(1)
Existing native vegetation and mature trees
I
I
have been preserved.
No trees or vegetation have been removed
(except for noxious or non-native) outside
7.28.050(h)(1)(i)
designated site disturbance areas on lots
greater than '/2 acre in the RL, RD and RM zone
districts.
All native landscaping has been kept in its
7.28.050(h)(1)(iii)
native state.
7.28.050(h)(1)(iv)
Significant Trees and vegetation that have been
•
N/A
AEC
STAFF COMMENTS
7.28.060(b)(1)
removed from the site has been replaced.
7.28.050(h)(1)(iv)(C)
The location of Protective Construction Fencing
has been identified on the plans.
7.28.050(h)(2)
Proposed plant materials' have been specified
on the plans
7.28.050(h)(3)
Noxious Vegetation has been identified for
properties
removal
Temporary installations of gas/oil tanks are
7.28.050(h)(4)
Irrigation Plan is included on the Landscape
7.28.060(b)(4)
screened from public ROW and/or neighboring
Plan.
properties.
SCREENING STANDARDS
CODE SECTION•.
•
N/A
AEC
STAFF COMMENTS
7.28.060(b)(1)
All outdoor refuse and recycling receptacles are
screened
All antennas are screened from view from an
7.28.060(b)(2)
public ROW or neighboring property
Satellite dishes are screened from neighboring
7.28.060(b)(3)
properties
Temporary installations of gas/oil tanks are
7.28.060(b)(4)
screened from public ROW and/or neighboring
properties.
Mechanical equipment is screened from public
7.28.060(d)
ROW and/or neighboring properties by a
parapet wall or similar feature that is an integral
part of the building's architectural design.
Load and service areas are in the rear, side or
7.28.060(e)
inside of building, not visible from public ROW
or adjacent residential uses.
7.28.060(f)
Outdoor storage areas are screen with
approved materials.
7.28.060(g)
Shopping carts are stored inside the building.
Shopping cart corrals are not plastic.
Dumpsters are screened with 6 fit masonry wall
7.28.060(h)
or wooden fence not visible for public ROW or
nei hboring property.
7.28.060(i)(1)
Plant materials are used to screen utility boxes
7.28.060 i 2 No fence, wall or hedge is tall than 6 ft
RETAINING WALLS
•
CODE SECTION•D
• NOCOMMENTS
7.28.070(b)(1)
Retaining walls are utilized because finished
Wildridge fence does not delineate the
grades cannot meet Code standards
property boundaries, is less than 4 ft in height,
Walls over 4 ft high are designed with a series of
split rail with no more than 2 rails, does not
7.28.070(b)(2)
terracing. The width of terrace is at least 5 ft.
delineate an area > 2,000 sf, and does not
Retaining walls over 7 ft in height have been
7.28.080(b)(1)
negatively affect wildlife migration. Multi -family
7.28.070(b)(3)
approved by PZC
fence is integrated into overall design of the
7.28.070(b)(4)
Wall material is compatible with site and
property. Duplex fence received approval from
buildings on site
adjoining property and fence is integrated into
Walls over 4 ft high have been structurally
overall design of the property.
7.28.070(b)(5)
designed and certified by Colo licensed
Walls and fences are architecturally compatible
engineer and approved by Town Engineer.
7.28.080(b)(2)(i)
with the style, materials, color of primary
FENCES
CODE SECTION•.
•
NOCOMMENTS
Wildridge fence does not delineate the
property boundaries, is less than 4 ft in height,
split rail with no more than 2 rails, does not
delineate an area > 2,000 sf, and does not
7.28.080(b)(1)
negatively affect wildlife migration. Multi -family
fence is integrated into overall design of the
property. Duplex fence received approval from
adjoining property and fence is integrated into
overall design of the property.
Walls and fences are architecturally compatible
7.28.080(b)(2)(i)
with the style, materials, color of primary
building s).
Fences and walls are not greater than 50 ft in
7.28.080(b)(2)(i)
solid, unbroken expanse length.
7.28.080 b 2 ii A
Fences material is compliant with Code
7.28.080(b)(2)(ii)(B)
Fences in front yard is at least 50% open.
Material has been approved by Director.
7.28.080(b)(2)(ii)(C)
Solid fences have been designed to meet
Building Code wind design criteria.
7.28.080(b)(2)(iii) Security fencing (razor , barbed wire or electric
charge) are prohibited.
7.28.080(b)(2)(iv) Fence conforms to height limits.
RESIDENTIAL DESIGN STANDARDS - Townhouse Design
RESIDENTIAL DESIGN STANDARDS - Multi Family Buildings
CODE SECTION..
•
NOCOMMENTS
Units with street frontage have individual
7.28.090(h)(1)
Buildings are oriented parallel to public street
7.28.090(g)(1)(ii)
ground -related entries accessible from the
or to the neighboring internal streets.
street. Enclosed rear yards backing up to the
Site plan demonstrate a unified, organized
street are not proposed.
7.28.090(h)(1)(i)(A)
design that incorporates open space with solar
Individual pedestrian entrances are
exposure, (e.g., interior courtyards or on-site
7.28.090(g)(1)(iii)
emphasized over garage entrances with trellis,
7.28.090(h)(1)(i)(B)
Walkways connect the entries of each building.
enclosed porch or other architectural feature.
Building served by a private internal roadway
r
7.28.090(g)(2)
has driveways that are limited in depth to de-
em hasize vehicular access.
7.28.090(g)(3)
Project with at least 6 units has provided 400 sf
of private common area for each unit.
The primary face of each building is design so
that it is evident where the units begin and end
7.28.090(g)(4)(i)
through subtly varying the offsetting of building
walls, material choices, parapet height and
color.
Building has achieved balance between
repetition and variety by employing modulation
7.28.090(g)(4)(ii)
techniques on individual units, such as
changing rooflines, building articulation and
windows.
RESIDENTIAL DESIGN STANDARDS - Multi Family Buildings
CODE SECTION..
•
NOCOMMENTS
7.28.090(h)(1)
Buildings are oriented parallel to public street
or to the neighboring internal streets.
Site plan demonstrate a unified, organized
7.28.090(h)(1)(i)(A)
design that incorporates open space with solar
exposure, (e.g., interior courtyards or on-site
natural areas) as unifying elements.
7.28.090(h)(1)(i)(B)
Walkways connect the entries of each building.
C
7.28.090(h)(2)
All ground floor units in a building with 6 or
more units are provided with a patio directly
accessible from units. All units above ground
floor are provided with balconies.
-family
CODE SECTION•.
•
• N/A AEC STAFF COMMENTS
Projects with at least 6 units have provided 400
Garage entries, carports, parking areas, and/or
sf of private common area for each unit.
Parking structures are internalized in building
7.28.090(h)(3)
Covered balconies, porches, decks or patios
groupings or oriented away from street
have been used to meet 50% of this
frontage.
requirement.
Parking areas and freestanding parking
Buildings have been designed with human
structures do not occupy more than thirty
scale, interest and variety, by providing
percent (30%) of each perimeter public street
7.28.090(h)(4)
changes in vertical and/or horizontal
frontage..
articulation, fenestration, building materials,
Above -grade parking structures that are visible
architectural style, and/or roof design.
from perimeter public streets are sited so that
RESIDENTIAL PARKING
LOCATION AND LAYOUT - Multi
-family
CODE SECTION•.
•
• N/A AEC STAFF COMMENTS
Garage entries, carports, parking areas, and/or
7.28.090(i)(1)(i)
Parking structures are internalized in building
groupings or oriented away from street
frontage.
Parking areas and freestanding parking
structures do not occupy more than thirty
7.28.090(i)(1)(ii)
percent (30%) of each perimeter public street
frontage..
Above -grade parking structures that are visible
from perimeter public streets are sited so that
7.28.090(i)(1)(iii)
the narrow end of the parking structure is
er endicular to the perimeter street.
Detached garages and carports incorporate
7.28.090(i)(1)(iv)
compatible materials, scale, colors,
architectural details, and roof slopes similar to
those of the primary buildings.
Rear walls of detached garages over forty (40)
feet in length that back onto the perimeter
7.28.090(i)(1)(v)
street or adjacent property lines are articulated
with window openings or other similar
technique.
DEVELOPMENT REVIEW CHECKLISTS — MIXED-USE, COMMERCIAL, & NON-RESIDENTIAL
ZONE DISTRICT STANDARDS
Date
Zone District:
Lot:
Subdivision:
This checklist is for the sole purpose of assisting the applicant in preparation of a development plan application. The applicant should refer to the
Avon Development Code and Application Submittal Requirements to complete a development plan application. This checklist is not an official part
of the Avon Development Code and should in no way be considered a replacement for the Code or instructions contained with the application.
Code
i Section
7.20
Code Requirement
Minimum Lot Size
Comply
Not
.Applicable
Not
Staff Comments
7.20
Minimum Lot Width
NO
NIA
AEC
STAFF COMMENTS
7.20
Maximum Lot Coverage
Bicycle/pedestrian paths are designed with
7.20
Minimum Landscape Area
7.28.040(e)
adequate widths, sight lines and appropriate
§ 7.20
Building Setbacks
lighting.
§ 7.20
Max Building Height
7.20
Max Number of Dwelling Units
7.28.040(e)(3)
§ 7.20.100
0 Deed Restricted Units
7.24
Use Permitted
MOBILITY AND CONNECTIVITY
- Bicycle and Pedestrian Paths
YES
NO
NIA
AEC
STAFF COMMENTS
CODE SECTION•.REQUIREMENT
Bicycle/pedestrian paths are designed with
7.28.040(e)
adequate widths, sight lines and appropriate
lighting.
Public sidewalks are located along perimeter
7.28.040(e)(3)
streets.
There a continuous, internal pedestrian walkway
7.28.040(e)(4)
provided from the perimeter public sidewalks to
the princi al buildings entrances.
7.28.040(e)(5)
Adequate bike parking facilities are provided.
7.28.040(e)(6)
Bicycle paths constructed in public right of way
meet TOA Standards.
7.28.040(e)(7)
Bicycle paths in private communities will be
CODE SECTION•D
• NOCOMMENTS
The proposed new subdivision street circulation
maintained by the HOA.
7.28.040(f)(2)(i)
plan provides multiple connections to the
Bicycle/pedestrian paths connect all adjacent
existing Town street network.
7.28.040(e)(8)
developments, neighborhoods, and typical
A cul de sac or dead-end street has been used
destinations (schools, public trails, rec facilities,
7.28.040(f)(2)(ii)(A)
due constraints such as existing topo, natural
etc .
features or vehicle safety.
7.28.040(e)(9)
Location of paths takes into consideration
A cul-de sac is not proposed for
existing travel patterns.
7.28.040(f)(2)(ii)(A)
commercial/industrial uses.
7.28.040(e)(1 0
Sidewalks are not located in areas prone to ice.
MOBILITY AND CONNECTIVITY
- Vehicle Circulation
CODE SECTION•D
• NOCOMMENTS
The proposed new subdivision street circulation
7.28.040(f)(2)(i)
plan provides multiple connections to the
existing Town street network.
A cul de sac or dead-end street has been used
7.28.040(f)(2)(ii)(A)
due constraints such as existing topo, natural
features or vehicle safety.
A cul-de sac is not proposed for
7.28.040(f)(2)(ii)(A)
commercial/industrial uses.
All permanent dead end streets have been
7.28.040(f)(2)(ii)(B)
designed as -cul de -sacs and extend no further
than 1000 linear feet.
7.28.040(f)(2)(ii)(C)
Proposed cul-de-sac conforms to Fire Code and
has been approved by Fire District.
Sir
7.28.040 f 2 ii D
No half streets are proposed.
A pedestrian access easement has been
7.28.040(f)(2)(ii)(E)
provided (10 ft wide), between the cul-de-sac
and the closest adjacent street or sidewalk.
The arrangement of streets in a development
provide for the alignment and continuation of
7.28.040(f)(3)(i)
existing of proposed streets. Traffic calming
measures shall be integrated into the
development to mitigate the impact of future
"cut -through) traffic.
LANDSCAPE STANDARDS
CODE SECTION•.
Street ROW shall extend to or along adjoining
NOCOMMENTS
7.28.050(d)
property boundaries so that a roadway
7.28.040(f)(3)(ii)
connection of street stub shall be provided for
ever 1,500 feet.
7.28.050(e)
Street and sidewalk connections shall be made
7.28.040(f)(3)(iii)
between neighborhood commercial and
residential.
LANDSCAPE STANDARDS
CODE SECTION•.
•
NOCOMMENTS
7.28.050(d)
If required does the landscape buffer meet code
requirements.
Does the application provide the necessary
7.28.050(e)
Landscape Units at a minimum of 1 unit per 50
square feet of landscaped area.
Is perimeter parking lot landscaping provided at
7.28.050(f)(1)
a minimum width of 6 feet and 1.2 landscape
units per lineal foot.
Is an internal landscape strip provided for every
7.28.050(f)(2)
other row of double row parking, when more
than 50 spaces are provided.
7.28.050(f)(4)
Does the internal landscaping island meet the
code's design requirements.
7.28.050(f)(5)
Does the internal landscaping strip meet the
code's design requirements.
Parking Lot Landscaping in TC District.
7.28.050(f)(6)
Does the proposed landscaping meet the code
requirements.
7.28.050(g)
Does the landscape plan respond to minimum
sight distance triangle requirements.
7.28.050(h)(1)
Existing native vegetation and mature trees
I
I
have been preserved.
No trees or vegetation have been removed
(except for noxious or non-native) outside
7.28.050(h)(1)(i)
designated site disturbance areas on lots
greater than '/2 acre in the RL, RD and RM zone
districts.
All native landscaping has been kept in its
7.28.050(h)(1)(iii)
native state.
7.28.050(h)(1)(iv)
Significant Trees and vegetation that have been
•
N/A
AEC
STAFF COMMENTS
7.28.060(b)(1)
removed from the site has been replaced.
7.28.050(h)(1)(iv)(C)
The location of Protective Construction Fencing
has been identified on the plans.
7.28.050(h)(2)
Proposed plant materials' have been specified
on the plans
7.28.050(h)(3)
Noxious Vegetation has been identified for
properties
removal
Temporary installations of gas/oil tanks are
7.28.050(h)(4)
Irrigation Plan is included on the Landscape
7.28.060(b)(4)
screened from public ROW and/or neighboring
Plan.
properties.
SCREENING STANDARDS
CODE SECTION•.
•
N/A
AEC
STAFF COMMENTS
7.28.060(b)(1)
All outdoor refuse and recycling receptacles are
screened
All antennas are screened from view from an
7.28.060(b)(2)
public ROW or neighboring property
Satellite dishes are screened from neighboring
7.28.060(b)(3)
properties
Temporary installations of gas/oil tanks are
7.28.060(b)(4)
screened from public ROW and/or neighboring
properties.
Mechanical equipment is screened from public
7.28.060(d)
ROW and/or neighboring properties by a
parapet wall or similar feature that is an integral
part of the building's architectural design.
Load and service areas are in the rear, side or
7.28.060(e)
inside of building, not visible from public ROW
or adjacent residential uses.
7.28.060(f)
Outdoor storage areas are screen with
approved materials.
7.28.060(g)
Shopping carts are stored inside the building.
Shopping cart corrals are not plastic.
Dumpsters are screened with 6 fit masonry wall
7.28.060(h)
or wooden fence not visible for public ROW or
nei hboring property.
7.28.060(i)(1)
Plant materials are used to screen utility boxes
7.28.060 i 2 No fence, wall or hedge is tall than 6 ft
RETAINING WALLS
•
CODE SECTION•D
• NOCOMMENTS
7.28.070(b)(1)
Retaining walls are utilized because finished
Wildridge fence does not delineate the
grades cannot meet Code standards
property boundaries, is less than 4 ft in height,
Walls over 4 ft high are designed with a series of
split rail with no more than 2 rails, does not
7.28.070(b)(2)
terracing. The width of terrace is at least 5 ft.
delineate an area > 2,000 sf, and does not
Retaining walls over 7 ft in height have been
7.28.080(b)(1)
negatively affect wildlife migration. Multi -family
7.28.070(b)(3)
approved by PZC
fence is integrated into overall design of the
7.28.070(b)(4)
Wall material is compatible with site and
property. Duplex fence received approval from
buildings on site
adjoining property and fence is integrated into
Walls over 4 ft high have been structurally
overall design of the property.
7.28.070(b)(5)
designed and certified by Colo licensed
Walls and fences are architecturally compatible
engineer and approved by Town Engineer.
7.28.080(b)(2)(i)
with the style, materials, color of primary
FENCES
CODE SECTION•.
•
NOCOMMENTS
Wildridge fence does not delineate the
property boundaries, is less than 4 ft in height,
split rail with no more than 2 rails, does not
delineate an area > 2,000 sf, and does not
7.28.080(b)(1)
negatively affect wildlife migration. Multi -family
fence is integrated into overall design of the
property. Duplex fence received approval from
adjoining property and fence is integrated into
overall design of the property.
Walls and fences are architecturally compatible
7.28.080(b)(2)(i)
with the style, materials, color of primary
building s).
Fences and walls are not greater than 50 ft in
7.28.080(b)(2)(i)
solid, unbroken expanse length.
7.28.080 b 2 ii A
Fences material is compliant with Code
7.28.080(b)(2)(ii)(B)
Fences in front yard is at least 50% open.
Material has been approved by Director.
7.28.080(b)(2)(ii)(C)
Solid fences have been designed to meet
Building Code wind design criteria.
7.28.080(b)(2)(iii) Security fencing (razor , barbed wire or electric
charge) are prohibited.
7.28.080(b)(2)(iv) Fence conforms to height limits.
MIXED USE AND
NON RESIDENTIAL - Site Layout and Design
(Building
Orientation,
Outparcels, Parking, Common Spaces)
CODE SECTION•.
•
NOCOMMENTS
7.28.0900)(3)(i)(A)
Building(s) re -enforce street edges and create
pedestrian scaled open space.
_
Building fronts and entries are oriented to
7.28.0900)(3)(i)(B)
street or public plaza
7.28.0900)(4)(ii)
Ground floor of new building is at grade or
7.28.0900)(3)(i)(B)
elevated above grade.
Outparcels and buildings define street edges,
7.28.0900)(3)(ii)
entry points and spaces for gathering or
seating between buildings. Space between
buildings includes pedestrian amenity.
7.28.0900)(3)(iii)
Parking is located behind building,
underground or at interior of lot.
Project include on —site, indoor and outdoor
7.28.0900)(3)(iv)
common spaces or community amenities as
visible, accessible focal points.
Common spaces have been designed to
7.28.0900)(3)(iv)(C)
minimize conflict with snow management
operations and ensure pedestrian safety.
MIXED USE AND
CODE SECTION•D
NON RESIDENTIAL - Building Layout and
•
Design
NOCOMMENTS
Building Design. Building design is
7.28.0900)(4)(i)
appropriate to the site and a positive element
in the architectural character of Avon.
_
Four-sided Design. The rear and side
elevations of the new building that is visible
7.28.0900)(4)(ii)
from public spaces and adjacent buildings is
designed with equal care and quality as the
front or principal face.
All buildings within the development, including
freestanding and accessory buildings, are
7.28.0900)(4)(iii)(A)
organized around an architectural theme in
terms of the character, materials, texture,
color, and scale of building.
Mixed-Use Buildings in Town Core To
encourage appropriate commercial and mixed-
use development in Town Core any portion of
a new mixed-used building with street frontage
7.28.0900)(4)(iv)
floor area located on E. Beaver Creek
Boulevard, Lettuce Shed Lane, Benchmark
Road, or Main Street must be occupied by
retail, personal service and restaurant uses, as
listed in Table 7.24-1
Scale and Massing. Form and massing of
7.28.0900)(4)(v)
the building provides a human scale to
adjacent streets, pedestrian walkways, plazas,
or other public spaces.
Buildings greater than two stories or 30 ft in
height are designed to reduce apparent mass,
7.28.0900)(4)(v)(B)
and visually anchor the building to the site by
including a clearly identifiable base, body, and
top, with horizontal elements separating these
components
Where primary building walls exceed 3 stories
or 45 ft in height, as measured from finished
grade to the underside of the eaves, building
form steps back at least 8 feet in depth and
generally occur between 12 t and 45 ft above
7.28.0900)(4)(v)(D)
the finished grade.
OR
Due to large variations in topography or other
unique site constraints, alternatives to the
building massing and height configurations
required have been approved.
Development Transition. The proposed
development relates to neighboring buildings
7.28.0900)(4)(vi)
using approved development transition
techniques..
Storefronts and Pedestrian Entrances. The
first floor of the proposed development
provides: a pedestrian friendly environment,
with human -scale and natural building
materials. Extensive storefront windows for
7.28.0900)(4)(vii)(A-
display and views into the business; and
B)
access directly from adjacent sidewalks
OR
Transparency is in conflict with internal
functions of the building, SO other means have
been used to activate the street facing facades
Building front entrances are located at intervals
7.28.0900)(4)(vii)(C)
of 32 ft maximum.
If applicable, primary access to retail spaces
7.28.0900)(4)(vii)(D)
on Benchmark Road, Main Street, and W.
Beaver Creek Boulevard, is from the sidewalk
Building provides direct access to ground floor
7.28.0900)(4)(vii)(E)
commercial space from the street.
The principal building entrance faces an
adjacent public street, public plaza, or primary
public walkway.
7.28.0900)(4)(vii)(E)(
OR
1-2)
The principal entrance does not face the
principal street, but the entrance is connected
to the street and adjacent parking areas with a
sidewalk.
Building entrance is welcoming to pedestrian
and easily identifiable and accessible from
7.28.0900)(4)(vii)(F)
streets and sidewalks. Primary entries are
clearly visible from the street and accentuated
from the overall building fagade.
Building Materials. The selection of building
materials, colors, architectural elements, and
7.28.0900)(4)(viii)
finishes contribute to the building's durability,
usefulness, and compatibility.
Roofs. Roofs use dormers to break up
7.28.0900)(4)(ix)
expansive roofs and add visual interest
All primary roofs and secondary shed roofs
7.28.0900)(4)(ix)(B)
shall have pitches of no less than four -to -
twelve 4:12 .
Roof overhang length(s) meet Code
7.28.0900)(4)(ix)(C)
requirements
Flat roofs are limited to areas to conceal
7.28.0900)(4)(ix)(D)
mechanical space or for architectural effect.
MIXED USE AND NON RESIDENTIAL - Parking Structures
CODE SECTION•.
Roofs are varied and articulated but will not
•COMMENTS
7.28.0900)(4)(ix)(E)
result in excess ice build up
7.28.090(j)(5)(i)
Roofs are proportional to the height and scale
of the various building elevations. The primary
7.28.090(j)(4)(ix)(F)
roof(s) and upper portion of the walls are
articulated so as to minimize their visual impact
on surrounding properties.
7.28.0900)(5)(iii)
Roof Material consistent with Code
7.28.0900)(4)(ix)(G)
requirements.
Windows. Openings contribute to the image
7.28.0900)(4)(x)(A)
and form of new building.
Buildings located on Main Street,
Benchmark Road, Lettuce Shed Lane, o E.
Beaver Creek Boulevard - Storefront
7.28.0900)(4)(x)(B)
incorporates a large display window or
windows of clear glass, bulkheads, recessed
entries, transom windows, and suitable
locations for signs at ground levels.
Upper floors are differentiated from ground
floor through the use of more solid areas then
voids and with smaller vertically oriented
7.28.0900)(4)(x)(C)
windows in a regular pattern. Windows reflect
a rhythm, scale and proportion compatible with
the overall building design.
Window materials and finishes consistent with
7.28.0900)(4)(x)(D)
Code requirements
Decks and Balconies are located to take
advantage of solar exposure, and are used in
7.28.0900)(4)(xi)
combination with bay windows and other
exterior projections.
MIXED USE AND NON RESIDENTIAL - Parking Structures
CODE SECTION•.
•
•COMMENTS
Ground floor of parking structures is wrapped
7.28.090(j)(5)(i)
with retail storefronts or residential uses along
those facades adjacent to or most visible from
major pedestrian walkways.
Exposed portions of the underground parking
structures are faced with base -level materials
7.28.0900)(5)(iii)
used on the active portions of the building
above the parking structure.
7.28.0900)(5)(iv)
Facades of single -use parking garage have
been articulated with 3 or more architectural
features.
The parking structures is designed to
significantly screen or buffer views of parked
7.28.0900)(5)(v)
cars from surrounding properties through the
use of architectural screens and other features.
Parking structure provides pedestrian access
to adjacent public walkways, public buildings,
7.28.0900)(5)(vi)
and/or public plazas without using major
access points along the primary street network
10
DEVELOPMENT REVIEW CHECKLISTS - NATURAL RESOURCE PROTECTION
ZONE DISTRICT STANDARDS
Date
Zone District:
Lot:
Subdivision:
This checklist is for the sole purpose of assisting the applicant in preparation of a development plan application. The applicant should refer to the
Avon Development Code and Application Submittal Requirements to complete a development plan application. This checklist is not an official part
of the Avon Development Code and should in no way be considered a replacement for the Code or instructions contained with the application.
Steep Slopes
CODE SECTION•.
•COMMENTS
Steep Slopes. Project is a new subdivision,
7.28.100(a)(2)
PUD or zoning amendment that contains lots
with naturally occurring slopes greater than
30%.
Development is not located on steep slopes of
7.28.100(a)(3)(iii)
40% or greater and areas greater than 40%
slope remain as natural open space.
The Lot contains a natural slope area greater
than 30% and larger than 2,500 sf and is a
7.28.100(a)(3)(iv)
minimum of 1 acre in size with a minimum
street frontage of 150 linear feet. Lot has not
been mass -graded to avoid this section.
The original, natural grade o f the Lot has not
been raised or lowered more than 6 feet at
7.28.100(a)(3)(v)
any point for construction of any structure or
improvement.
Graded or Filled Man -Made Cut man-made
surfaces or slopes do not exceed a slope
7.28.100(a)(3)(vi)(A-
between twenty-five percent (25%) and fifty
C)
percent (50%)
OR
Town Engineer has approved alternative.
7.28.100(a)(3)(vi)(D)
Cut exposed bedrock is proposed to be
sculpted to appear natural.
Sheet notes indicate that all cut, filled, and
7.28. 1 00(a)(3)(vi)(E)
graded slopes shall be re-contoured to the
natural, varied contour of the surrounding
terrain
7.28.100(a)(3)(vii)(A)
Natural Design. Sharp angles have been
rounded off.
Slopes provide transition from graded areas
7.28.100(a)(3)(vi)(B)
into natural areas by varying grade both up-
slope and across the slope.
7.28.100(a)(3)(vi)(C)
Natural grade at the lot line has been
maintained.
Separate Pads. The project does not cut and
7.28.100(a)(3)(viii)(A)
grade to create benches or pads for buildings
or structures.
Accessory structures and buildings (other than
7.28.100(a)(3)(viii)(B)
garage) are not located on separate building
pads except for areas with slopes 20% or less.
Parking Areas. Parking areas should be
constructed on multiple levels and follow
7.28.100(a)(3)(ix)
natural contours as necessary to minimize cut
and fill.
7.28.100(a)(3)(x)
Retaining walls have been used to minimize
cut and fill.
7.28.100(a)(3)(xi)(A)
Natural Drainage Patterns. Site plan does
not change natural drainage patterns.
Natural surface drainage patterns have been
preserved OR
7.28.100(a)(3)(xi)(B)
Natural drainage patterns are modified and
appropriate stabilization techniques have been
employed.
Development has mitigated all negative or
7.28.100(a)(3)(xi)(C)
adverse drainage impacts on adjacent and
surrounding sites
Standard erosion control methods shall be
used during construction to protect water
7.28.100(a)(3)(xi)(D)
quality, control drainage, and reduce soil
erosion
Revegatation. Landscape plan indicated that
7.28.100(a)(3)(xii)
areas exposed during construction will be
re ve atated.
7.28.100(a)(3)(xiii)(A)
Streets, Roads, General Site Access.
Project includes at least three units.
7.28.100(a)(3)(xiii)(B)
Access to the development site is by road,
street, or private access road
Streets, roads, private access roads, and
7.28.100(a)(3)(xiii)(C)
other vehicular routes comply with all
requirements of the Town of Avon
Streets, roads, private access roads, and
other vehicular routes do not cross slopes
between 30% and 50%.
7.28.100(a)(3)(xiii)(D)
OR
Roads that do cross slopes between 30 and
50% will require PZC approval.
7.28.100(a)(3)(xiii)(E)
Under no circumstances do the proposed
roads cross slopes greater than 50 percent..
Streets, roads, private access roads, and
7.28.100(a)(3)(xiii)(F)
other vehicular routes have, to the maximum
extent feasible, follow natural contour lines.
DRIVEWAY ACCESS Grading for streets,
roads, private access roads, and other
vehicular routes has been limited to the
asphalt portion of the right-of-way, plus up to
an additional ten (10) feet on either side of the
asphalt as needed.
OR
7.28.100(a)(3)(xiii)(G)
Access is on slopes in excess of twenty
percent (25%), so only the asphalt portion of
the right-of-way has been a graded plus the
minimum area required for any necessary
curb, gutter, or sidewalk improvements. The
remainder of the access right-of-way has been
left undisturbed to the maximum extent
feasible.
Roads, other vehicular routes, or trails
ARE/ARE NOT required to provide access or
maintain existing access to adjacent lands for
7.28.100(a)(3)(xiii)(H)
vehicles, pedestrians, emergency services,
and essential service and maintenance
equipment.
Stream, River, Waterbodv and Wetlands
CODE SECTION•D
•
•COMMENTS
Nondegradation. The applicant has provided
evidence and plans to ensure that the
proposed development does not result in
7.28.100(b)(3)
reasonably avoidable degradation of streams,
rivers, or wetlands. This condition applies to
both the development activities and the
ultimate use of the land
Riparian buffers have been established from
the mean annual high water line (AHWL), as
7.28.100(b)(4)
determined by the Town Engineer, on each
side of the perennial stream or river, water
body, or wetland.
The Riparian Protection Buffer is thirty (30)
7.28.100(b)(5)(ii)
feet from the AHWL.
7.28.100(b)(5)(iii)
The Director HAS/HAS NOT requested a
specific survey of the extent of riparian zone.
Permitted Uses and Activities. Except as
required to accommodate a permitted use or
activity, all existing vegetation within the
7.28.100(b)(5)(iv)
riparian protection buffer has been
preserved and, where necessary to provide
adequate screening or to repair damaged
riparian areas, supplemented with additional
native or adapted planting and landscaping.
The Uses and Management Activities in the
7.28. 1 00(b)(5)(v)
riparian protection buffer comply with the
Code.
7.28.100(b)(5)(v)(H)
No disturbance of land has been proposed
within riparian buffers.
A proposed bridge over the riparian feature and
within the riparian buffer has been planned and
7.28.100(b)(5)(v)(1)
constructed so as to minimize impacts on the
riparian feature and minimizes disturbance and
removal of vegetation.
Grading, Erosions Prevention and Sedimentation Control
CODE SECTION•D. •STAFF
Ephemeral Streams. Development is not
Applicability. This section shall apply to any disturbance within one hundred (100) feet of a stream, all grading unless waived by the Town Engineer, all
residential development disturbing more than one-quarter (1/4) acre, all mixed use, commercial, and industrial development and all proposed
subdivisions and PVDs
No grading has occurred without a permit
located within the channel of an ephemeral
7.28.100(c)(3)
issued by Town Engineer
stream, as defined by its AHWL
Grading plans conformances with the
OR
7.28.100(c)(3)(i)
7.28.100(b)(6)
The Town Council has granted waivers or
Erosion Control Standards Construction
modifications from this prohibition upon a
7.28.100(c)(4)(i)
activities such as clearing, grading, road
finding that the development will have no
construction and utilities installation have been
adverse environmental impacts, or that such
phased to minimize soil exposure.
impacts will be substantially mitigated
Grading, Erosions Prevention and Sedimentation Control
CODE SECTION•D. •STAFF
COMMENTS
Applicability. This section shall apply to any disturbance within one hundred (100) feet of a stream, all grading unless waived by the Town Engineer, all
residential development disturbing more than one-quarter (1/4) acre, all mixed use, commercial, and industrial development and all proposed
subdivisions and PVDs
No grading has occurred without a permit
7.28.100(c)(3)
issued by Town Engineer
Grading plans conformances with the
7.28.100(c)(3)(i)
International Building Code IBC
Erosion Control Standards Construction
7.28.100(c)(4)(i)
activities such as clearing, grading, road
construction and utilities installation have been
phased to minimize soil exposure.
Soil Stabilization. All disturbed areas and soil
stockpiles have been surface roughened,
mulched, seeded and mulched, or otherwise
protected from erosive forces if they are to
7.28.100(c)(4)(ii)
remain exposed and inactive for periods longer
than fourteen (14) days or if soil will be
exposed during winter. On slopes greater than
20% or within 50 feet of any water body,
exposed soils will be hydro -mulched or covered
with nets or mats
7.28.100(c)(4)(iii)
Excavation. Excavation for footings and
foundations have been minimized.
Cut and Fill Slopes. Permanent vegetation
has been used as to stabilize cut and fill areas
where slopes are less than or equal to two -to -
one (2:1).
On cut and fill slopes steeper than two -to -one
7.28. 1 00(c)(4)(iv)
(2:1), stabilization has been attained by
utilizing retaining walls, rock walls, up slope
runoff diversions, slope drains, or other
measures appropriate for the specific situation.
Rockfall mitigation has been proposed for
slopes steeper than two -to -one 2:1 .
Construction in or Adjacent to a Water
Body. Construction in or directly adjacent to
7.28.100(c)(4)(v)
any water body, such as culvert or bridge
installation, includes bed and bank
stabilization.
Channels and Ditches. New or re-routed
irrigation ditches, receiving channels, and
7.28. 1 00(c)(4)(vi)
streams have been protected so that flows
from the site do not cause erosion and
flooding.
Stormwater Runoff. Stormwater runoff flows
has been managed to minimize erosion and
7.28.100(c)(4)(vii)
sediment transport. Concentrated flows have
been diverted away from disturbed slopes.
Sediment and Mud Control. Sediment and
mud will be controlled and prevented from
leaving the construction site by immediate
7.28.100(c)(4)(viii)
placement of street base or construction of
mud pads in access routes. Mud pads will be
least 50 feet in length and comprised of
angular rock and/or a wheel washing facility.
Contributing drainage area, including off-
site area, is greater than one (1) acre:
Sediment detention ponds, infiltration devices,
and other management practices that store or
detain runoff have been used to treat sediment-
7.28.100(c)(4)(ix)
containing runoff prior to discharge from the
construction site.
OR
Contributing drainage area is less than one
(1) acres: Specific engineered design for
sediment trapping facilities is not required.
Temporary Sediment Ponds. Temporary
sediment ponds that will be removed after
successful revegetation of the site are
designed to safely detain and release all
storms up to and including the twenty-five (25)
year, twenty-four (24) hour storm at its historic,
7.28.100(c)(4)(x)
pre -development rate of release.
OR
Ponds that will be left as permanent facilities
have one hundred (100) year flood capacity
and meet dam and diversion requirements of
the state engineer.
Construction De -Watering. All construction
7.28. 1 00(c)(4)(xi)
de -watering activities conform with the state's
construction de -watering permit requirements.
Inspection and Maintenance. The applicant
7.28.100(c)(4)(xii)
shall inspect all erosion and sediment control
devices monthly.
Permanent Revegetation. Any disturbed area
that is not built upon for a period of one (1)
7.28.100(c)(4)(xiii)
year or longer will be revegetated pursuant to
§7.28.100(c)(6), Revegetation Plan
Erosion and Sediment Control Plan. An
applicant for any development listed in
7.28.100(c)(5)
§7.28.100(c)(2), Applicability, has submitted
an erosion and sediment control plan prepared
by a qualified professional.
Revegation Plan. A revegetation and land
reclamation plan prepared and certified by a
7.28.100(c)(6)
qualified professional IS/IS NOT required by
the Director for review and approval.
Geologic Hazard Areas
CODE SECTION•D• NOCOMMENTS
Applicability. After November 16, 2010, new development is prohibited within geologic hazard areas. In the event that there is no hazard -free area on a
platted site, then development shall be restricted to the least hazardous area of a site, as approved by the Director based on a study by a qualified
engineer licensed b the State of Colorado. _
Minimum Mitigations Standards: A.
structural geologic hazard defenses that are
designed by a certified engineer to withstand
the impact forces. B. Utility lines or pipes that
7.28. 1 00(e)(3)(i)
cross a geologic hazard area have been buried
C. Clear -cutting or other large-scale removal of
vegetation is prohibited D. Extractive
operations have an approved program of
eolo is control and defense measures.
Surface pipes, poles, or towers for suspended
7.28.100(e)(3)(ii)
transmission lines in hazard zones shall be
protected
_
Warning signs shall be placed along roads and
7.28.100(e)(3)(vi)
trails that cross rockfall and avalanche hazard
zones.
Property owners who develop in geologic
hazard areas or obtain driveway access
7.28.100(e)(3)(vii)
through geologic hazard areas shall bear the
costs of any control measures that may be
required to mitigate the hazard
Geological Hazard Study. Applicability. A geologic hazard study shall be required for all subdivisions, PUDs, rezonings, and lots containing or may
contain geologic hazards as defined by the Development Code
Requirements for Preliminary Approval of
Study. A. Site specific analysis B. Evaluation
7.28.100(e)(4)(iii)
of potentials impacts C. Plan includes building
envelopes D. Identification and description of
all proposed hazard mitigation and avoidance
measures
Study has been referred to Colorado
7.28.100(e)(4)(iv)
Geological Survey for review and comments.
Requirements for Final Approval. The
applicant has demonstrated in the final plan or
7.28.100(e)(4)(v)
plat how the development complies with all
conditions imposed in the preliminary approval.
DEVELOPMENT REVIEW CHECKLISTS - ALTERNATIVE ENERGY STANDARDS
ZONE DISTRICT STANDARDS
Date
Zone District:
Lot:
ly • .'a
Subdivision:
This checklist is for the sole purpose of assisting the applicant in preparation of a development plan application. The applicant should refer to the
Avon Development Code and Application Submittal Requirements to complete a development plan application. This checklist is not an official part
of the Avon Development Code and should in no way be considered a replacement for the Code or instructions contained with the application.
CODE SECTION•. • NOCOMMENTS
Ground -Mounted Solar Collection System
System is not located in the front yard between
the principal structure and the public right-of-
way.
System complies with all setback requirements.
If located in a residential district, the system
does not exceed the greater of 1/2 the footprint
of the principal structure or 600 square feet,
7.28. 1 00(g)(2)(i)(A)
whichever is less. T
If located in a mixed-use and non-residential
districts he size of accessory arrays does not
exceed 1/2 of the footprint of the principal
structure.
A ground -mounted system does not exceed ten
(10) feet in height.
Solar Easements. The property owner has
been made aware that it is his/her responsible
for negotiating with other property owners in
7.28. 1 00(g)(2)(i)(B)
the vicinity for any necessary solar easement
and shall record the easement in the Eagle
County land records
Roof -Mounted Solar Collection System
System does not extend more than 2 feet
above a pitched roof or 6 feet above a flat roof.
With the exception of flat roofs, the system
placed on the roof mimics the roof pitch it is
attached to.
7.28.100(g)(3)(i)(A)
System IS/IS NOT located on an accessory
structure.
Applicant will provide a structural certification
as part of the building permit application.
Solar Easements. The property owner has
been made aware that it is his/her responsible
for negotiating with other property owners in
7.28. 1 00(g)(3)(i)(B)
the vicinity for any necessary solar easement
and shall record the easement in the Eagle
County land records.
Small Wind Energy System
Setback. The base of the tower is set back
from all property lines, public right-of-ways,
and public utility lines a distance equal to the
total extended height (e.g., if on a roof, roof
height plus tower height) plus five (5) feet.
OR tower is closer to a property line than its
total extended height because the abutting
property owner(s) has provided written
permission and the installation poses no
interference with public utility lines or public
road and rail right-of-ways
7.28.100(g)(4)(ii)
Sound. Under normal operating conditions,
the sound generated by turbine will not
exceed (55) dBA (measured at property line).
Appearance, Color, and Finish. The turbine
and tower will be painted or finished in non -
reflective, non -obtrusive color.
Clearance. Minimum ground clearance is 15
feet as measured at the lowest point of the arc
of the blades.
Signage on system is prohibited.
Lighting. No illumination unless required by
the FAA.
Access. Any climbing foot pegs or rungs
below 12 feet of a freestanding tower will be
removed to prevent unauthorized climbing.
Compliance with FAA Regulations. System
does not project above any of the imaginary
airspace surfaces described in FAR Part 77 of
the FAA guidance on airspace protection.
Utility Notification. Applicant has provided
evidence that the relevant electric utility
company has been informed of the customer's
intent to install an interconnected customer-
owned generator.