PZC Packet 110387STAFF REPORT TO PLANNING & ZONING COMMISSION - 11/3/87 Lot 21, Block 2, Benchmark at Beaver Creek Avon Commercial Building - Building Modifications and Site Plan - Design Review INTRODUCTION: At the meeting of October 51 1987, the Commission determined that Slifer Designs was compatible with the parking requirements previously set forth for the building. At that meeting there was lengthy discussion about existing on-site parking spaces and the fact that the project is currently 2 spaces short of the minimum parking required for uses already in the building. The applicant was directed to address the parking issue along with design review for modifications to the building exterior. Plans have been submitted which show additional parking spaces and additional retail space proposed for the project. STAFF COMMENTS: The applicant has submitted plans which show Slifer Designs at the south end of the building, Christy Sports expanding their retail operation by 828 square feet, a vacant space of 888 square feet that the applicant would like approval for more retail space, the existing Vail Associates offices, and a site plan showing 48 parking spaces. Although the parking calculations shown on the site plan are correct, there are flaws in the site plan that limit the number of accessible parking spaces to 44, the number required for those uses currently in the building. In front of the building the site plan shows one row with 18 spaces, one row with 20 spaces, and one area in front of the proposed Slifer Designs space with 4 spaces. The 18 spaces and the 4 spaces are all right, but due to the location of the drive from Avon Road, it is only possible to fit 19 spaces, not 20, in the other row. There are 2 spaces proposed north of the stairway to Christy Sports. These 2 spaces are unacceptable because they have no legal access. The applicant also shows 4 spaces back at the southeast corner of the property by the trash enclosure. The applicant submitted a drawing showing the dumpster being moved to add one space for a total of 4. This drawing shows the trash enclosure moving 10 feet to the south. The trash enclosure as it currently exists is only 2 feet from the property line and there is 32 feet from the enclosure to the building. Due to the existing conditions in the field, the enclosure cannot be moved enough to add a fourth space, so only 3 spaces can be counted in this area. Based on field measurements and observations, Staff feels that a maximum of 44 accessible parking spaces can be provided on-site in the general configuration of the proposed site plan. si Staff ort to Planning & Zoning Commission - 11/3/87 Lot 21, ock 2, Benchmark at Beaver Creek Avon C, w2rcial Building - Building Modifications and Site Plan - Design Review Page 2 of 2 STAFF RECOMMENDATIONS: Staff recommends that, if the Commission approves the modifications to the buildinu exterior, the applicant be directed to provide the 44 parking spaces required for uses currently in the building, ane that no approvals be granted for additional retail space until such time as adequate parking is provided for the additional retail space. RECOMMENDED ACTIONS: 1. Introduce project; 2. Presentation by applicant; 3. Commission review of submitted material; 4. Act on application. Respectfully Submitte , n I.-!,[1 ) � Wht Engineering Tle-t(nician Planning & Zoning Action: Approved as Submitted ( ) Approved with Recommended Conditions (Lf Approved with Modified Conditions ( ) Continued ( } Denied ( ) Withdrawn ( ) Date -3 az.- 1�? Michael Blair, Secretary )ld" !ncl STAFF REPORT TO PLANNING & ZONING COMMISSION - 11/3/87 Lots 26/27, Block Mountain Center - Public Hearing INTRODUCTION, 1, Benchmark at Beaver Creek Variance Request Vail Building Arts Associates, owners of the Mountain Center project now under construction on Lots 26/27, Block 1, Benchmark at Beaver Creek, are requesting a variance from the Zoning Cude to exclude the mini -storage space in the basement from the parking requirements for the project. The applicant feels that since an interior driveway has been provided to access the mini -storage bays, surface parking for this space is unnecessary. STAFF COMMENTS: There is approximately 6,000 square feet in the basement of the building that could be used for mini -storage bays. At the requirement of 1 space for 800 square feet (warehouse) this area would require approximately 8 parking spaces. If this request were granted, these spaces would be available to other tenants in the building. Section 17.36-040 Approval Criteria, states: Before acting on a variance application, the design review board shall consider the following factors with respect to the requested variance: A. The relationship of the requested variance to other existing or potential uses and structures in the vicinity; B. The degree to which relief from the strict or literal interpretation and enforcements of a specified regulation is necessary to achieve compati- bility and uniformity of treatment among sites in the vicinity, or to attain the objectives of this title without grant of special privilege; C. The effect of the requested variance on light and air, distribution of population, transportation and traffic facilities, and public facilities and utilities, and public safety; D. Such other factors and criteria as the board deems applicable to the proposed variance. (Ord. 81-9 S1(d)). Section 17 36 050 Findings Required, states: The Planning and Zoning Commission shall make the following written findings before granting a variance: A. That the granting of the variance will not constitute a grant of special privilege inconsistent with the limitations on other properties classified in the same district; Staff Report to Planning & Zoning Commission - 11/3/87 Lots 26/27, Block 1, Benchmark at Beaver Creek Mountain Center - Variance Request Public Hearing Page 2 of 3 B. That the granting of the variance will not be detrimental to the public health, safety, or welfare, or materially injurious to properties or improvements in the vicinity; C. That the variance is warranted for one or more of the following reasons: 1. The strict, literal interpretation and enforcement of the specified regulation would result in practical difficulty or unnecessary physical hardship inconsistent with the objectives of this title; 2. There are exceptional or extraordinary circumstances or conditions applicable to the site of the variance that do not apply generally to other properties in the same zone; 3. The strict or literal interpretation and enforcement of the specified regulation would deprive the applicant of privileges enjoyed by the owners of other properties in the same district. (ord. 81-9 S1(e)). STAFF RECOMMENDATIONS: Ir the Commission approves this variance request, the appropriate action would bo to adopt Resolution 87-14 which Staff has prepared. If the Commission denies this request, the Resolution should be modified to reflect the reasons for denial. RECOMMENDED ACTIONS: 1. introduce variance request; 2. Presentation by anplicant; 3. Conduct Public Hearing; 4. Commission's review of criteria and findings required for approval of the variance; 5. Amend Resolution 87-14 to reflect Commission findings and desired action; 6. Adopt Resolution 87-14 as amended. Respectfully Submitted, dri Eneerir(g Technician Staff Report to Planning & Zoning Commission - 11/3/87 Lots 26/27, Block 1, Benchmark at Beaver Creek Mountain Center - Variance Request Public Hearing Page 3 of 3 Planning & Zonin Action: Approved as Submitted ( ) Approved with Recommended Conditions { ) Approved with Modified Conditions ( ) Continued ( ) Denied ( ) Withdrawn ( ) Dice 3 <<�„�r B Michael Blair, Secretary k6J'nunl STAFF REPORT TO PLANNING & ZONING COMMISSION - 11/3/87 Lots 26/27, Bloch 1, Benchmark at Beaver Creek Mountain Center - Special Review Use Request to Allow General Commercial Offices and Personal Service Outlets Public Hearing INTRODUCTION: Vail Building Arts Associates, owners of the Mountain Center project now under construction on Lots 26/27, Block 1, Benchmark at Beaver Creek, has requested approval of a Special Review Use to allow general commercial offices and personal service outlets in the project. The original approval for the project limited the uses in the building to those uses specifically allowed in the IC Zone District. General comnerc W offices and personal service outlets are only allowed in the IC Zone District with Special Review Use approval. STAFF COMMENTS: If the pravious variance request for the project was approved which excludes the mini -storage area from the parking requirements for the protect, Staff estimates that the total leaseable area for Phase I is approximately 26,00 square feet. Parking requirements based on 1 space/800 square feet would mead that 34 spaces are required for Phase I. If the parking is constructed per the approved site plan, there would be approximately 56 parking spaces available for Phase I. This leaves approximately 21 spaces above the minimum parking requirements for Phase I which could be applied to the general commercial office and personal service outlets requirement of 3 spaces per 1,000 square feet. Under this scenario, the developer could devote approximately 10,000 square feet in Phase I to general commercial office and personal service outlet uses. Since a site plan has not been submitted showing parking for Phase II, it is difficult to determine parking requirements for Phase II. Staff feels that, if the Cumnission approves this Special Review Use request, that approval may be granted for the entire project, but each request for general commercial office or personal service outlet uses should be reviewed by Staff for conformance with parking requirements and that general commercial office and personal service outlet occipants be limited to an amount fer which on-site parking is available. RECOMMENDED PROCEDURE: According to Section 17.20.040 of the Zoning Code, the Commission shall approve or deny the Special Review Use after considering certain factors that are listed below. Those items in parentheses are Staff responses to the criteria: A. The adequacy of access to the site with respect to the width of the adjacent streets, their grades, intersectirn safety, visibility and entrance into the lot to be developed: (The existing street, Nottingham Road, and the existing access onto Lots 26/27 are both adequate to handle the traffic generated by the proposed use.) Staff Report to Planning & Zoning Commission - 11/3/87 Lots 26/27, Block 1, Benchmark at Beaver Creek Mountain Center - Special Review Use Request to Allow General Commercial Offices and Personal Service Outlets Public Hearing Page 2 of 3 B. Whether there exists safe access and sufficient water pressure to provide fire protection; (The site has sufficient access and water pressure for fire protection.) C. The existent water pressure in the area and the ability of the water system to supply domestic needs; (The proposed use should not greatly increase water needs for the project.) D. Whether there will be provided sufficient off-street parking as determined by (1) the intended use of the property, (2) walking distance to the downtown area, and (3) the availability of public transportation; E. The impact of the development, considering the potential for stream and air pollution, the availability of public transportation and other public or private services, and any other factors affecting the overall development and the surrounding areas, including but not limited to building height, view plane, drainage and other physical and aesthetical features. STAFF RECOMMENDATIONS: If the Commission approves this Special Review Use request, the appropriate action would be to adopt Resolution 87-15 which Staff has prepared. If the Commission denies this request the Resolution should be modified to reflect the reasons for denial. RECOMMENDED ACTIONS: 1. Introduce Special Review Use request; 2. Presentation by applicant; 3. Conduct Public Hearing; 4. Commission's review of criteria required for Special Review Use approval; 5. Amend Resolution 87-15 to reflect Commission finding and desired action; 6. Adopt Resolution 87-15 as amended. Respectfully Submitted, y "riVtnTechnician E g nee Staff Report to Planning & Zoning Commission - 11/3/87 Lots 26/27, Block 1, Benchmark at Beaver Creek Mountain Center - Special Review Use Request to Allow General Commercial Offices and Personal Service Outlets Public Hearing Page 3 of 3 940, Planning & Zoning Action: Approved as Submitted K) Approved with Recommended Conditions ( ) Approved with Modified Conditions ( ) Continued ( ) Denied ( ) Withdrawn ( ) Date,/-rv� g /g / Michael Blair, Secretary . 15 RW/mml STAFF REPORT TO PLANNING & ZONING COMMISSION - 11/3/87 Lot 3, Block 1, Benchmark at Beaver Creek Vail/Beaver Creek Resort Real Estate Development Sign - Design Review INTRODUCTION: Vail/Beaver Creek Resort Real Estate has applied for design review of a development sign for Lot 3, Block 1, Benchmark Subdivision. The proposed sign is approximately 8 square feet and will have red lettering on a white background. STAFF COMMENTS: Section 15.28.080(H) (Development Signs) states: 1. Only one sign per parcel, lot, or group of contiguous lots under one ownership, not to exceed sixteen square feet of display area and eight feet in height; 2. Signs must be removed within thirty days of land sale or upon issuance of a certificate of occupancy; 3. In no case may a sign be retained for more than two years, unless an extension is granted by the planning and zoning commission. If the Commission approves this be directed to place the sign at right-of-way. RECOMMENDED ACTIONS: 1. Introduce project; 2. Presentation by applicant; request, Staff recommends that the applicant least 10' from the property lines and road 3. Commission review of submitted materials; 4. Act on application. Respectfully Submitted, kW igering Technician Staff Report to Planning and Zoning Commission Lot 3, Block 1, Benchmark at Beaver Creek Vail/Beaver Creek Resort Real Estate Development Sign - Design Review Page 2 of 2 Planning & Zoning Action: Approved as Submitted ( ) Approved with Recommended Conditions (t--' Approved with Modified Conditions ( ) Continued ( ) Denied ( ) Withdrawn ( ) Date 3 'B7 Michael Blair, Secretary