L4 NTST Design ModTown of Avon
Preliminary Design Staff Report
December 16, 1997 Planning & Zoning Commission meeting
Report date December 11, 1997
Project type Design Modification
Legal description Buildings G, H, & I, Lot 4, Nottingham Station
Subdivision — Canyon Run
Zoning Planned Unit Development (PUD)
Address 0270, 0290, & 0320 Hurd Lane
Introduction
Patrick W. Nook & Associates, representing Canyon Run LLC and Shapiro Development
Company, has applied to modify the approved Final Design for Canyon Run's last three
buildings — G, H, and I. Comparative changes and similarities include the following:
• Increasing Building G's units from six to eight. This modification requires adjusting the
interior building envelope lines, as allowed by the project's PUD.
• All one level units (some with lofts) differing from previous two level units.
• Eliminating unit entryways from building sides. All units will now be accessed from the
central courtyards.
• Addition of carports to the outer edge of each attached garage.
• Relocating chimneys from the side elevations to the rear elevations.
• Creating forty-five degree exterior walls for the end units to accommodate "longer" views of
the river. The exterior decks, however, still give a squared appearance to these units.
The overall architectural design, colors and materials are consistent with Canyon Run's existing
buildings.
The applicant is seeking Preliminary Design approval for the proposed modifications' general
concepts while continuing to work with staff on a number of specific design issues.
Design Review Considerations
The Commission's Procedures, Rules & Regulations, Section 6. 10, provide the framework for
evaluation of this project. Additional guidelines and regulations are contained within (but not
limited to) the Comprehensive Plan, the Design Guidelines, the Zoning Ordinance and the
Subdivision Regulations.
Conformance with the Zoning Code and other applicable regulations of the Town.
2. The suitability of the improvement, including type and quality of materials of which it is to
be constructed and the site upon which it is to be located.
3. The compatibility of the design to minimize site impacts to adjacent properties.
4. The compatibility of the proposed improvements with site topography.
Town of Avon Community Development j:\p&z\1997\121697\ghinotstatpre.doc
(970) 949-4280 Fax (970) 949-5749
Buildings G, H, and 1, Lot 4, Nottingham Station — Canyon Run; Preliminary Design Review
December 16, 1997, Planning & Zoning Commission meeting
5. The visual appearance of any proposed improvement as viewed from adjacent and
neighboring properties and public ways.
6. The objective that no improvement be so similar or dissimilar to others in the vicinity that
values, monetary or aesthetic will be impaired.
7. The general conformance of the proposed improvements with the adopted Goals, Policies
and Programs for the Town of Avon.
Staff Comments
Staff believes the design modifications proposed for Buildings G, H, and I are compatible with
the existing Canyon Run project. However, we have identified three primary code and design
issues and a number of additional issues that should be addressed prior to Final Design
consideration.
Primary Code and Design Issues:
1. Building G is approximately two feet over the fifty -foot maximum building height.
2. One building design is being applied to three very different topographic conditions. The
result is a plan that relies on excessive site modification.
3. The retaining wall along the eastern property line exceeds four feet in height, violating the
project's setbacks. The cause of this condition relates to comment #2 above.
Additional Issues:
1. The interior building envelope line between buildings H and I has not been modified to
accommodate the building footprint adjustments.
2. Grading information is incomplete behind Building H and to the east of Building I.
3. The parking table lists forty-eight surface parking spaces while the site plan indicates thirty-
three surface spaces.
4. The courtyard details on the site plan and landscape plan are inconsistent.
Concern whether the indicated tree wells will function to preserve existing trees due to their
extreme depth. This issue also relates to Primary Design Issue #2 above.
6. Indicate on the site plan summary table both the actual and the maximum allowable
residential floor area square footage.
7. A minimal amount of snow storage area is provided (Town of Avon standard is an area equal
to 20% of the paved surface). How will snow removal and storage be handled?
Staff recommends that the Commission give Preliminary Design approval for the design
modifications for Buildings G, H, and I subject to satisfactory resolution of the above design
issues.
Recommended Motion
"I move to approve the Preliminary Design for Buildings G, H, and I of Lot 4, Nottingham
Station as presented on the plans dated received November 25, 1997, subject to the satisfactory
resolution of the design issues as outlined in the staff report dated December 11, 1997."
Town of Avon Community Development j:\p&z\1997\121697\ghinotstatpre.doc
970) 949-4280 Fax (970) 949-5749
Buildings G, H, and I, Lot 4, Nottingham Station — Canyon Run; Preliminary Design Review
December 16, 1997, Planning & Zoning Commission meeting
If you have any questions regarding this project or any planning matter, please call me at
949-4280 (extension 139), or stop by the Community Development Department.
Re 1
r m
P1 r
Town of Avon Community Development j:\p&z\1997\121697\ghinotstatpre.doc
970) 949-4280 Fax (970) 949-5749
Buildings G, H, and I, Lot 4, Nottingham Station — Canyon Run; Preliminary Design Review
December 16, 1997, Planning & Zoning Commission meeting
Planning & Zoning Commission Action
❑ Preliminary Approval as submitted
❑ Denied
❑ Tabled
Preliminary Approved with conditions
❑ Withdrawn by applicant
Conditions of approval, reasons for tabling or withdrawal of application, or basis for denial (refer
to code or guidelines by number):
Date
I -z -Ie --11
Andrew Karow, Chair
Attest:,
Date 167152 2
Town of Avon Community Development j:\p&z\1997\121697\ghinotstatpre.doc